Sufficiency of Longitudinal Moment of Inertia for Haptic Cylinder Length Judgments
Identifieur interne : 000D78 ( PascalFrancis/Curation ); précédent : 000D77; suivant : 000D79Sufficiency of Longitudinal Moment of Inertia for Haptic Cylinder Length Judgments
Auteurs : Patrick A. Cabe [Royaume-Uni]Source :
- Journal of experimental psychology. Human perception and performance [ 0096-1523 ] ; 2010.
Descripteurs français
- Pascal (Inist)
- Wicri :
English descriptors
- KwdEn :
Abstract
Many studies invoke moment of inertia (Iii) as necessary and sufficient information to perceive cylinder length via wielding, yet some assert that Iii is neither necessary (weight, m, or static moment, M, are sufficient) nor sufficient for length judgments (m or M is necessary). Mathematical expressions for Iii not involving m or M imply length, so Iii could be sufficient for cylinder length judgments. In 5 experiments (N = 113), only longitudinal Iii (the smallest principal value) informed cylinder length estimates in a novel task, rolling. Experiment 1 yielded reliable length judgments. Varying diameter supported length scaling (Experiment 2); similar length estimates occurred with both rolling and wielding (Experiment 3); feedback improved rolling length judgments to levels commensurate with wielding (Experiment 4); and length judgments shifted predictably with added mass (Experiment 5). Contrary to proposals in the literature, Iii is sufficient information for cylinder length judgments, absent m or M information, even when Iii is of minimal magnitude and the task quite novel.
pA |
|
---|
Links toward previous steps (curation, corpus...)
- to stream PascalFrancis, to step Corpus: Pour aller vers cette notice dans l'étape Curation :000627
- to stream PascalFrancis, to step Corpus: Pour aller vers cette notice dans l'étape Curation :000709
Links to Exploration step
Pascal:10-0247193Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en" level="a">Sufficiency of Longitudinal Moment of Inertia for Haptic Cylinder Length Judgments</title>
<author><name sortKey="Cabe, Patrick A" sort="Cabe, Patrick A" uniqKey="Cabe P" first="Patrick A." last="Cabe">Patrick A. Cabe</name>
<affiliation wicri:level="1"><inist:fA14 i1="01"><s1>University of North Carolina</s1>
<s2>Pembroke</s2>
<s3>GBR</s3>
<sZ>1 aut.</sZ>
</inist:fA14>
<country>Royaume-Uni</country>
</affiliation>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">INIST</idno>
<idno type="inist">10-0247193</idno>
<date when="2010">2010</date>
<idno type="stanalyst">PASCAL 10-0247193 INIST</idno>
<idno type="RBID">Pascal:10-0247193</idno>
<idno type="wicri:Area/PascalFrancis/Corpus">000627</idno>
<idno type="stanalyst">FRANCIS 10-0247193 INIST</idno>
<idno type="wicri:Area/PascalFrancis/Corpus">000709</idno>
<idno type="wicri:Area/PascalFrancis/Curation">000D78</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en" level="a">Sufficiency of Longitudinal Moment of Inertia for Haptic Cylinder Length Judgments</title>
<author><name sortKey="Cabe, Patrick A" sort="Cabe, Patrick A" uniqKey="Cabe P" first="Patrick A." last="Cabe">Patrick A. Cabe</name>
<affiliation wicri:level="1"><inist:fA14 i1="01"><s1>University of North Carolina</s1>
<s2>Pembroke</s2>
<s3>GBR</s3>
<sZ>1 aut.</sZ>
</inist:fA14>
<country>Royaume-Uni</country>
</affiliation>
</author>
</analytic>
<series><title level="j" type="main">Journal of experimental psychology. Human perception and performance</title>
<title level="j" type="abbreviated">J. exp. psychol. Hum. percept. perform.</title>
<idno type="ISSN">0096-1523</idno>
<imprint><date when="2010">2010</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt><title level="j" type="main">Journal of experimental psychology. Human perception and performance</title>
<title level="j" type="abbreviated">J. exp. psychol. Hum. percept. perform.</title>
<idno type="ISSN">0096-1523</idno>
</seriesStmt>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Experimental study</term>
<term>Human</term>
<term>Inertia</term>
<term>Judgment</term>
<term>Length</term>
<term>Space perception</term>
<term>Tactile sensitivity</term>
</keywords>
<keywords scheme="Pascal" xml:lang="fr"><term>Sensibilité tactile</term>
<term>Longueur</term>
<term>Jugement</term>
<term>Perception espace</term>
<term>Etude expérimentale</term>
<term>Inertie</term>
<term>Homme</term>
</keywords>
<keywords scheme="Wicri" type="topic" xml:lang="fr"><term>Jugement</term>
<term>Homme</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">Many studies invoke moment of inertia (I<sub>ii</sub>
) as necessary and sufficient information to perceive cylinder length via wielding, yet some assert that I<sub>ii</sub>
is neither necessary (weight, m, or static moment, M, are sufficient) nor sufficient for length judgments (m or M is necessary). Mathematical expressions for I<sub>ii</sub>
not involving m or M imply length, so I<sub>ii</sub>
could be sufficient for cylinder length judgments. In 5 experiments (N = 113), only longitudinal I<sub>ii</sub>
(the smallest principal value) informed cylinder length estimates in a novel task, rolling. Experiment 1 yielded reliable length judgments. Varying diameter supported length scaling (Experiment 2); similar length estimates occurred with both rolling and wielding (Experiment 3); feedback improved rolling length judgments to levels commensurate with wielding (Experiment 4); and length judgments shifted predictably with added mass (Experiment 5). Contrary to proposals in the literature, I<sub>ii</sub>
is sufficient information for cylinder length judgments, absent m or M information, even when I<sub>ii</sub>
is of minimal magnitude and the task quite novel.</div>
</front>
</TEI>
<inist><standard h6="B"><pA><fA01 i1="01" i2="1"><s0>0096-1523</s0>
</fA01>
<fA02 i1="01"><s0>JPHPDH</s0>
</fA02>
<fA03 i2="1"><s0>J. exp. psychol. Hum. percept. perform.</s0>
</fA03>
<fA05><s2>36</s2>
</fA05>
<fA06><s2>2</s2>
</fA06>
<fA08 i1="01" i2="1" l="ENG"><s1>Sufficiency of Longitudinal Moment of Inertia for Haptic Cylinder Length Judgments</s1>
</fA08>
<fA11 i1="01" i2="1"><s1>CABE (Patrick A.)</s1>
</fA11>
<fA14 i1="01"><s1>University of North Carolina</s1>
<s2>Pembroke</s2>
<s3>GBR</s3>
<sZ>1 aut.</sZ>
</fA14>
<fA20><s1>373-394</s1>
</fA20>
<fA21><s1>2010</s1>
</fA21>
<fA23 i1="01"><s0>ENG</s0>
</fA23>
<fA43 i1="01"><s1>INIST</s1>
<s2>3032D</s2>
<s5>354000181121030090</s5>
</fA43>
<fA44><s0>0000</s0>
<s1>© 2010 INIST-CNRS. All rights reserved.</s1>
</fA44>
<fA45><s0>2 p.</s0>
</fA45>
<fA47 i1="01" i2="1"><s0>10-0247193</s0>
</fA47>
<fA60><s1>P</s1>
</fA60>
<fA61><s0>A</s0>
</fA61>
<fA64 i1="01" i2="1"><s0>Journal of experimental psychology. Human perception and performance</s0>
</fA64>
<fA66 i1="01"><s0>USA</s0>
</fA66>
<fC01 i1="01" l="ENG"><s0>Many studies invoke moment of inertia (I<sub>ii</sub>
) as necessary and sufficient information to perceive cylinder length via wielding, yet some assert that I<sub>ii</sub>
is neither necessary (weight, m, or static moment, M, are sufficient) nor sufficient for length judgments (m or M is necessary). Mathematical expressions for I<sub>ii</sub>
not involving m or M imply length, so I<sub>ii</sub>
could be sufficient for cylinder length judgments. In 5 experiments (N = 113), only longitudinal I<sub>ii</sub>
(the smallest principal value) informed cylinder length estimates in a novel task, rolling. Experiment 1 yielded reliable length judgments. Varying diameter supported length scaling (Experiment 2); similar length estimates occurred with both rolling and wielding (Experiment 3); feedback improved rolling length judgments to levels commensurate with wielding (Experiment 4); and length judgments shifted predictably with added mass (Experiment 5). Contrary to proposals in the literature, I<sub>ii</sub>
is sufficient information for cylinder length judgments, absent m or M information, even when I<sub>ii</sub>
is of minimal magnitude and the task quite novel.</s0>
</fC01>
<fC02 i1="01" i2="X"><s0>002A26E05</s0>
</fC02>
<fC03 i1="01" i2="X" l="FRE"><s0>Sensibilité tactile</s0>
<s5>01</s5>
</fC03>
<fC03 i1="01" i2="X" l="ENG"><s0>Tactile sensitivity</s0>
<s5>01</s5>
</fC03>
<fC03 i1="01" i2="X" l="SPA"><s0>Sensibilidad tactil</s0>
<s5>01</s5>
</fC03>
<fC03 i1="02" i2="X" l="FRE"><s0>Longueur</s0>
<s5>02</s5>
</fC03>
<fC03 i1="02" i2="X" l="ENG"><s0>Length</s0>
<s5>02</s5>
</fC03>
<fC03 i1="02" i2="X" l="SPA"><s0>Longitud</s0>
<s5>02</s5>
</fC03>
<fC03 i1="03" i2="X" l="FRE"><s0>Jugement</s0>
<s5>03</s5>
</fC03>
<fC03 i1="03" i2="X" l="ENG"><s0>Judgment</s0>
<s5>03</s5>
</fC03>
<fC03 i1="03" i2="X" l="SPA"><s0>Juicio</s0>
<s5>03</s5>
</fC03>
<fC03 i1="04" i2="X" l="FRE"><s0>Perception espace</s0>
<s5>04</s5>
</fC03>
<fC03 i1="04" i2="X" l="ENG"><s0>Space perception</s0>
<s5>04</s5>
</fC03>
<fC03 i1="04" i2="X" l="SPA"><s0>Percepción espacio</s0>
<s5>04</s5>
</fC03>
<fC03 i1="05" i2="X" l="FRE"><s0>Etude expérimentale</s0>
<s5>05</s5>
</fC03>
<fC03 i1="05" i2="X" l="ENG"><s0>Experimental study</s0>
<s5>05</s5>
</fC03>
<fC03 i1="05" i2="X" l="SPA"><s0>Estudio experimental</s0>
<s5>05</s5>
</fC03>
<fC03 i1="06" i2="X" l="FRE"><s0>Inertie</s0>
<s5>06</s5>
</fC03>
<fC03 i1="06" i2="X" l="ENG"><s0>Inertia</s0>
<s5>06</s5>
</fC03>
<fC03 i1="06" i2="X" l="SPA"><s0>Inercia</s0>
<s5>06</s5>
</fC03>
<fC03 i1="07" i2="X" l="FRE"><s0>Homme</s0>
<s5>18</s5>
</fC03>
<fC03 i1="07" i2="X" l="ENG"><s0>Human</s0>
<s5>18</s5>
</fC03>
<fC03 i1="07" i2="X" l="SPA"><s0>Hombre</s0>
<s5>18</s5>
</fC03>
<fC07 i1="01" i2="X" l="FRE"><s0>Perception</s0>
<s5>37</s5>
</fC07>
<fC07 i1="01" i2="X" l="ENG"><s0>Perception</s0>
<s5>37</s5>
</fC07>
<fC07 i1="01" i2="X" l="SPA"><s0>Percepción</s0>
<s5>37</s5>
</fC07>
<fC07 i1="02" i2="X" l="FRE"><s0>Cognition</s0>
<s5>38</s5>
</fC07>
<fC07 i1="02" i2="X" l="ENG"><s0>Cognition</s0>
<s5>38</s5>
</fC07>
<fC07 i1="02" i2="X" l="SPA"><s0>Cognición</s0>
<s5>38</s5>
</fC07>
<fN21><s1>165</s1>
</fN21>
</pA>
</standard>
</inist>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PascalFrancis/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000D78 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/PascalFrancis/Curation/biblio.hfd -nk 000D78 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Ticri/CIDE |area= HapticV1 |flux= PascalFrancis |étape= Curation |type= RBID |clé= Pascal:10-0247193 |texte= Sufficiency of Longitudinal Moment of Inertia for Haptic Cylinder Length Judgments }}
This area was generated with Dilib version V0.6.23. |