Abstract

Aim: To evaluate the outcome of surface deposits that occurred during implantation of hydrophylic acrylic intraocular lenses (IOLs) through a hexagonal cartridge. Methods: Surface deposits were observed on the posterior surface of the ACR6D SE IOLs that were injected through a hexagonal cartridge filled with sodium hyaluronate 1%. All the patients were examined 1 day, 1 week, 1 month, 6 months and 1 year postoperatively. The location of the deposits was recorded and photographed. The patients were questioned about blurred vision, glare or halos. Results: Linear or curly deposits were detected on the posterior surface of the IOL in six patients. In four patients, the deposits were peripheral and were observed 1 week postoperatively. In two patients, the deposits were noticed immediately after implantation. In one eye, they were misinterpreted as a crack in the IOL’s optic and were left in the eye. In the second patient the deposits were removed immediately after implantation with forceps. The deposits that were left after implantation (five eyes) did not resolve during 1 year of follow-up. None of the eyes developed abnormal inflammatory reaction. In three eyes the best-corrected visual acuity (BCVA) was 6/6. In the other three eyes the BCVA was 6/12. None of the patients experienced any visual disturbance. Conclusions: Implantation of the ACR6D SE IOL through a hexagonal cartridge can lead to the formation of deposits on the posterior surface of the lens. The deposits do not resolve and may resemble a crack in the IOL. The deposits left on the IOL had no clinical relevance in our patients.

Url:
DOI: 10.1136/bjo.2006.097857


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI wicri:istexFullTextTei="biblStruct">
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">The course of surface deposits on a hydrophilic acrylic intraocular lens after implantation through a hexagonal cartridge</title>
<author>
<name sortKey="Marcovich, A L" sort="Marcovich, A L" uniqKey="Marcovich A" first="A L" last="Marcovich">A L Marcovich</name>
</author>
<author>
<name sortKey="Kleinmann, G" sort="Kleinmann, G" uniqKey="Kleinmann G" first="G" last="Kleinmann">G. Kleinmann</name>
</author>
<author>
<name sortKey="Epstein, D" sort="Epstein, D" uniqKey="Epstein D" first="D" last="Epstein">D. Epstein</name>
</author>
<author>
<name sortKey="Pollack, A" sort="Pollack, A" uniqKey="Pollack A" first="A" last="Pollack">A. Pollack</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:5A1CCFD01417C9D88F4865C1E0B2F3F443855869</idno>
<date when="2006" year="2006">2006</date>
<idno type="doi">10.1136/bjo.2006.097857</idno>
<idno type="url">https://api.istex.fr/document/5A1CCFD01417C9D88F4865C1E0B2F3F443855869/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">000037</idno>
<idno type="wicri:Area/Istex/Curation">000037</idno>
<idno type="wicri:Area/Istex/Checkpoint">001C29</idno>
<idno type="wicri:doubleKey">0007-1161:2006:Marcovich A:the:course:of</idno>
<idno type="wicri:source">PMC</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC1857429</idno>
<idno type="RBID">PMC:1857429</idno>
<idno type="wicri:Area/Pmc/Corpus">000944</idno>
<idno type="wicri:Area/Pmc/Curation">000944</idno>
<idno type="wicri:Area/Pmc/Checkpoint">002510</idno>
<idno type="wicri:Area/Ncbi/Merge">000954</idno>
<idno type="wicri:Area/Ncbi/Curation">000954</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">000954</idno>
<idno type="wicri:doubleKey">0007-1161:2006:Marcovich A:the:course:of</idno>
<idno type="wicri:Area/Main/Merge">005F77</idno>
<idno type="wicri:Area/Main/Curation">005D36</idno>
<idno type="wicri:Area/Main/Exploration">005D36</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title level="a" type="main" xml:lang="en">The course of surface deposits on a hydrophilic acrylic intraocular lens after implantation through a hexagonal cartridge</title>
<author>
<name sortKey="Marcovich, A L" sort="Marcovich, A L" uniqKey="Marcovich A" first="A L" last="Marcovich">A L Marcovich</name>
<affiliation wicri:level="1">
<country xml:lang="fr">Israël</country>
<wicri:regionArea>Department of Ophthalmology, Kaplan Medical Center, Rehovot</wicri:regionArea>
<wicri:noRegion>Rehovot</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Kleinmann, G" sort="Kleinmann, G" uniqKey="Kleinmann G" first="G" last="Kleinmann">G. Kleinmann</name>
<affiliation wicri:level="2">
<country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Department of Ophthalmology and Visual Sciences, Laboratories for Ophthalmic Devices Research, John A Moran Eye Center, University of Utah, Salt Lake City, Utah</wicri:regionArea>
<placeName>
<region type="state">Utah</region>
</placeName>
</affiliation>
</author>
<author>
<name sortKey="Epstein, D" sort="Epstein, D" uniqKey="Epstein D" first="D" last="Epstein">D. Epstein</name>
<affiliation wicri:level="1">
<country xml:lang="fr">Israël</country>
<wicri:regionArea>Department of Ophthalmology, Kaplan Medical Center, Rehovot</wicri:regionArea>
<wicri:noRegion>Rehovot</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Pollack, A" sort="Pollack, A" uniqKey="Pollack A" first="A" last="Pollack">A. Pollack</name>
<affiliation wicri:level="1">
<country xml:lang="fr">Israël</country>
<wicri:regionArea>Department of Ophthalmology, Kaplan Medical Center, Rehovot</wicri:regionArea>
<wicri:noRegion>Rehovot</wicri:noRegion>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series>
<title level="j">British Journal of Ophthalmology</title>
<title level="j" type="abbrev">Br J Ophthalmol</title>
<idno type="ISSN">0007-1161</idno>
<idno type="eISSN">1468-2079</idno>
<imprint>
<publisher>BMJ Publishing Group Ltd.</publisher>
<pubPlace>BMA House, Tavistock Square, London, WC1H 9JR</pubPlace>
<date type="published" when="2006-10">2006-10</date>
<biblScope unit="volume">90</biblScope>
<biblScope unit="issue">10</biblScope>
<biblScope unit="page" from="1249">1249</biblScope>
</imprint>
<idno type="ISSN">0007-1161</idno>
</series>
<idno type="istex">5A1CCFD01417C9D88F4865C1E0B2F3F443855869</idno>
<idno type="DOI">10.1136/bjo.2006.097857</idno>
<idno type="href">bjophthalmol-90-1249.pdf</idno>
<idno type="PMID">16854825</idno>
<idno type="local">0901249</idno>
</biblStruct>
</sourceDesc>
<seriesStmt>
<idno type="ISSN">0007-1161</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass></textClass>
<langUsage>
<language ident="en">en</language>
</langUsage>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Aim: To evaluate the outcome of surface deposits that occurred during implantation of hydrophylic acrylic intraocular lenses (IOLs) through a hexagonal cartridge. Methods: Surface deposits were observed on the posterior surface of the ACR6D SE IOLs that were injected through a hexagonal cartridge filled with sodium hyaluronate 1%. All the patients were examined 1 day, 1 week, 1 month, 6 months and 1 year postoperatively. The location of the deposits was recorded and photographed. The patients were questioned about blurred vision, glare or halos. Results: Linear or curly deposits were detected on the posterior surface of the IOL in six patients. In four patients, the deposits were peripheral and were observed 1 week postoperatively. In two patients, the deposits were noticed immediately after implantation. In one eye, they were misinterpreted as a crack in the IOL’s optic and were left in the eye. In the second patient the deposits were removed immediately after implantation with forceps. The deposits that were left after implantation (five eyes) did not resolve during 1 year of follow-up. None of the eyes developed abnormal inflammatory reaction. In three eyes the best-corrected visual acuity (BCVA) was 6/6. In the other three eyes the BCVA was 6/12. None of the patients experienced any visual disturbance. Conclusions: Implantation of the ACR6D SE IOL through a hexagonal cartridge can lead to the formation of deposits on the posterior surface of the lens. The deposits do not resolve and may resemble a crack in the IOL. The deposits left on the IOL had no clinical relevance in our patients.</div>
</front>
</TEI>
<affiliations>
<list>
<country>
<li>Israël</li>
<li>États-Unis</li>
</country>
<region>
<li>Utah</li>
</region>
</list>
<tree>
<country name="Israël">
<noRegion>
<name sortKey="Marcovich, A L" sort="Marcovich, A L" uniqKey="Marcovich A" first="A L" last="Marcovich">A L Marcovich</name>
</noRegion>
<name sortKey="Epstein, D" sort="Epstein, D" uniqKey="Epstein D" first="D" last="Epstein">D. Epstein</name>
<name sortKey="Pollack, A" sort="Pollack, A" uniqKey="Pollack A" first="A" last="Pollack">A. Pollack</name>
</country>
<country name="États-Unis">
<region name="Utah">
<name sortKey="Kleinmann, G" sort="Kleinmann, G" uniqKey="Kleinmann G" first="G" last="Kleinmann">G. Kleinmann</name>
</region>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 005D36 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 005D36 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     ISTEX:5A1CCFD01417C9D88F4865C1E0B2F3F443855869
   |texte=   The course of surface deposits on a hydrophilic acrylic intraocular lens after implantation through a hexagonal cartridge
}}

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024