Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

The refractive outcome of Toric Lentis Mplus implant in cataract surgery

Identifieur interne : 000041 ( Main/Exploration ); précédent : 000040; suivant : 000042

The refractive outcome of Toric Lentis Mplus implant in cataract surgery

Auteurs : Patrick J. Chiam [Royaume-Uni] ; Say A. Quah [Royaume-Uni]

Source :

RBID : PMC:4886883

Abstract

AIM

To evaluate the refractive outcome of Toric Lentis Mplus intraocular lens (IOL) implant.

METHODS

This is a retrospective case series. Consecutive patients with corneal astigmatism of at least 1.5 D had Toric Lentis Mplus IOL implant during cataract surgery. The exclusion criteria included irregular astigmatism on corneal topography, large scotopic pupil diameter (>6 mm), poor visual potential and significant ocular comorbidity. Postoperative manifest refraction, uncorrected distance visual acuity (UDVA), best-corrected distance visual acuity (BCVA), uncorrected intermediate visual acuity (UIVA) at 3/4 m and uncorrected near visual acuity (UNVA) were obtained.

RESULTS

There were 70 eyes from 49 patients in this study. Patients were refracted at a median of 8.9wk (range 4.0 to 15.5) from the operation date. Sixty-five percent of eyes had 6/7.5 (0.10 logMAR) or better, and 99% 6/12 (0.30 logMAR) or better postoperative UDVA. Eighty-nine percent could read Jaeger (J) 3 (0.28 logMAR) and 95% J5 (0.37 logMAR) at 40 cm. The median magnitude of astigmatism decreased from 1.91 D to 0.49 D (Wilcoxon, P<0.001) after the operation. The range of the cylindrical error was reduced from 1.5-3.95 D (keratometric) preoperatively to 0.00-1.46 D (subjective refraction transposed to corneal plane) postoperatively.

CONCLUSION

Toric Lentis Mplus IOL has good predictability in reducing preexisting corneal astigmatism.


Url:
DOI: 10.18240/ijo.2016.05.10
PubMed: NONE
PubMed Central: 4886883


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">The refractive outcome of Toric Lentis Mplus implant in cataract surgery</title>
<author>
<name sortKey="Chiam, Patrick J" sort="Chiam, Patrick J" uniqKey="Chiam P" first="Patrick J" last="Chiam">Patrick J. Chiam</name>
<affiliation wicri:level="1">
<nlm:aff id="aff1">
<addr-line>Birmingham and Midland Eye Centre, City Hospital, Birmingham BH18 7QH, United Kingdom</addr-line>
</nlm:aff>
<country xml:lang="fr">Royaume-Uni</country>
<wicri:regionArea>Birmingham and Midland Eye Centre, City Hospital, Birmingham BH18 7QH</wicri:regionArea>
<wicri:noRegion>Birmingham BH18 7QH</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Quah, Say A" sort="Quah, Say A" uniqKey="Quah S" first="Say A" last="Quah">Say A. Quah</name>
<affiliation wicri:level="1">
<nlm:aff id="aff2">
<addr-line>Optegra Manchester Eye Hospital, Manchester M20 2EY, United Kingdom</addr-line>
</nlm:aff>
<country xml:lang="fr">Royaume-Uni</country>
<wicri:regionArea>Optegra Manchester Eye Hospital, Manchester M20 2EY</wicri:regionArea>
<wicri:noRegion>Manchester M20 2EY</wicri:noRegion>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PMC</idno>
<idno type="pmc">4886883</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4886883</idno>
<idno type="RBID">PMC:4886883</idno>
<idno type="doi">10.18240/ijo.2016.05.10</idno>
<idno type="pmid">NONE</idno>
<date when="2016">2016</date>
<idno type="wicri:Area/Pmc/Corpus">000454</idno>
<idno type="wicri:Area/Pmc/Curation">000454</idno>
<idno type="wicri:Area/Pmc/Checkpoint">000021</idno>
<idno type="wicri:Area/Ncbi/Merge">004800</idno>
<idno type="wicri:Area/Ncbi/Curation">004800</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">004800</idno>
<idno type="wicri:doubleKey">2222-3959:2016:Chiam P:the:refractive:outcome</idno>
<idno type="wicri:Area/Main/Merge">000041</idno>
<idno type="wicri:Area/Main/Curation">000041</idno>
<idno type="wicri:Area/Main/Exploration">000041</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a" type="main">The refractive outcome of Toric Lentis Mplus implant in cataract surgery</title>
<author>
<name sortKey="Chiam, Patrick J" sort="Chiam, Patrick J" uniqKey="Chiam P" first="Patrick J" last="Chiam">Patrick J. Chiam</name>
<affiliation wicri:level="1">
<nlm:aff id="aff1">
<addr-line>Birmingham and Midland Eye Centre, City Hospital, Birmingham BH18 7QH, United Kingdom</addr-line>
</nlm:aff>
<country xml:lang="fr">Royaume-Uni</country>
<wicri:regionArea>Birmingham and Midland Eye Centre, City Hospital, Birmingham BH18 7QH</wicri:regionArea>
<wicri:noRegion>Birmingham BH18 7QH</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Quah, Say A" sort="Quah, Say A" uniqKey="Quah S" first="Say A" last="Quah">Say A. Quah</name>
<affiliation wicri:level="1">
<nlm:aff id="aff2">
<addr-line>Optegra Manchester Eye Hospital, Manchester M20 2EY, United Kingdom</addr-line>
</nlm:aff>
<country xml:lang="fr">Royaume-Uni</country>
<wicri:regionArea>Optegra Manchester Eye Hospital, Manchester M20 2EY</wicri:regionArea>
<wicri:noRegion>Manchester M20 2EY</wicri:noRegion>
</affiliation>
</author>
</analytic>
<series>
<title level="j">International Journal of Ophthalmology</title>
<idno type="ISSN">2222-3959</idno>
<idno type="eISSN">2227-4898</idno>
<imprint>
<date when="2016">2016</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">
<sec>
<title>AIM</title>
<p>To evaluate the refractive outcome of Toric Lentis Mplus intraocular lens (IOL) implant.</p>
</sec>
<sec>
<title>METHODS</title>
<p>This is a retrospective case series. Consecutive patients with corneal astigmatism of at least 1.5 D had Toric Lentis Mplus IOL implant during cataract surgery. The exclusion criteria included irregular astigmatism on corneal topography, large scotopic pupil diameter (>6 mm), poor visual potential and significant ocular comorbidity. Postoperative manifest refraction, uncorrected distance visual acuity (UDVA), best-corrected distance visual acuity (BCVA), uncorrected intermediate visual acuity (UIVA) at 3/4 m and uncorrected near visual acuity (UNVA) were obtained.</p>
</sec>
<sec>
<title>RESULTS</title>
<p>There were 70 eyes from 49 patients in this study. Patients were refracted at a median of 8.9wk (range 4.0 to 15.5) from the operation date. Sixty-five percent of eyes had 6/7.5 (0.10 logMAR) or better, and 99% 6/12 (0.30 logMAR) or better postoperative UDVA. Eighty-nine percent could read Jaeger (J) 3 (0.28 logMAR) and 95% J5 (0.37 logMAR) at 40 cm. The median magnitude of astigmatism decreased from 1.91 D to 0.49 D (Wilcoxon,
<italic>P</italic>
<0.001) after the operation. The range of the cylindrical error was reduced from 1.5-3.95 D (keratometric) preoperatively to 0.00-1.46 D (subjective refraction transposed to corneal plane) postoperatively.</p>
</sec>
<sec>
<title>CONCLUSION</title>
<p>Toric Lentis Mplus IOL has good predictability in reducing preexisting corneal astigmatism.</p>
</sec>
</div>
</front>
</TEI>
<affiliations>
<list>
<country>
<li>Royaume-Uni</li>
</country>
</list>
<tree>
<country name="Royaume-Uni">
<noRegion>
<name sortKey="Chiam, Patrick J" sort="Chiam, Patrick J" uniqKey="Chiam P" first="Patrick J" last="Chiam">Patrick J. Chiam</name>
</noRegion>
<name sortKey="Quah, Say A" sort="Quah, Say A" uniqKey="Quah S" first="Say A" last="Quah">Say A. Quah</name>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000041 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 000041 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     PMC:4886883
   |texte=   The refractive outcome of Toric Lentis Mplus implant in cataract surgery
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Exploration/RBID.i   -Sk "pubmed:NONE" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024