Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

The refractive outcome of Toric Lentis Mplus implant in cataract surgery

Identifieur interne : 000454 ( Pmc/Corpus ); précédent : 000453; suivant : 000455

The refractive outcome of Toric Lentis Mplus implant in cataract surgery

Auteurs : Patrick J. Chiam ; Say A. Quah

Source :

RBID : PMC:4886883

Abstract

AIM

To evaluate the refractive outcome of Toric Lentis Mplus intraocular lens (IOL) implant.

METHODS

This is a retrospective case series. Consecutive patients with corneal astigmatism of at least 1.5 D had Toric Lentis Mplus IOL implant during cataract surgery. The exclusion criteria included irregular astigmatism on corneal topography, large scotopic pupil diameter (>6 mm), poor visual potential and significant ocular comorbidity. Postoperative manifest refraction, uncorrected distance visual acuity (UDVA), best-corrected distance visual acuity (BCVA), uncorrected intermediate visual acuity (UIVA) at 3/4 m and uncorrected near visual acuity (UNVA) were obtained.

RESULTS

There were 70 eyes from 49 patients in this study. Patients were refracted at a median of 8.9wk (range 4.0 to 15.5) from the operation date. Sixty-five percent of eyes had 6/7.5 (0.10 logMAR) or better, and 99% 6/12 (0.30 logMAR) or better postoperative UDVA. Eighty-nine percent could read Jaeger (J) 3 (0.28 logMAR) and 95% J5 (0.37 logMAR) at 40 cm. The median magnitude of astigmatism decreased from 1.91 D to 0.49 D (Wilcoxon, P<0.001) after the operation. The range of the cylindrical error was reduced from 1.5-3.95 D (keratometric) preoperatively to 0.00-1.46 D (subjective refraction transposed to corneal plane) postoperatively.

CONCLUSION

Toric Lentis Mplus IOL has good predictability in reducing preexisting corneal astigmatism.


Url:
DOI: 10.18240/ijo.2016.05.10
PubMed: NONE
PubMed Central: 4886883

Links to Exploration step

PMC:4886883***** Acces problem to record *****\

Le document en format XML


Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Pmc/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000454 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd -nk 000454 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Pmc
   |étape=   Corpus
   |type=    RBID
   |clé=     PMC:4886883
   |texte=   The refractive outcome of Toric Lentis Mplus implant in cataract surgery
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/RBID.i   -Sk "pubmed:NONE" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024