The refractive outcome of Toric Lentis Mplus implant in cataract surgery
Identifieur interne : 004800 ( Ncbi/Merge ); précédent : 004799; suivant : 004801The refractive outcome of Toric Lentis Mplus implant in cataract surgery
Auteurs : Patrick J. Chiam [Royaume-Uni] ; Say A. Quah [Royaume-Uni]Source :
- International Journal of Ophthalmology [ 2222-3959 ] ; 2016.
Abstract
To evaluate the refractive outcome of Toric Lentis Mplus intraocular lens (IOL) implant.
This is a retrospective case series. Consecutive patients with corneal astigmatism of at least 1.5 D had Toric Lentis Mplus IOL implant during cataract surgery. The exclusion criteria included irregular astigmatism on corneal topography, large scotopic pupil diameter (>6 mm), poor visual potential and significant ocular comorbidity. Postoperative manifest refraction, uncorrected distance visual acuity (UDVA), best-corrected distance visual acuity (BCVA), uncorrected intermediate visual acuity (UIVA) at 3/4 m and uncorrected near visual acuity (UNVA) were obtained.
There were 70 eyes from 49 patients in this study. Patients were refracted at a median of 8.9wk (range 4.0 to 15.5) from the operation date. Sixty-five percent of eyes had 6/7.5 (0.10 logMAR) or better, and 99% 6/12 (0.30 logMAR) or better postoperative UDVA. Eighty-nine percent could read Jaeger (J) 3 (0.28 logMAR) and 95% J5 (0.37 logMAR) at 40 cm. The median magnitude of astigmatism decreased from 1.91 D to 0.49 D (Wilcoxon,
Toric Lentis Mplus IOL has good predictability in reducing preexisting corneal astigmatism.
Url:
DOI: 10.18240/ijo.2016.05.10
PubMed: NONE
PubMed Central: 4886883
Links toward previous steps (curation, corpus...)
- to stream Pmc, to step Corpus: 000454
- to stream Pmc, to step Curation: 000454
- to stream Pmc, to step Checkpoint: 000021
Links to Exploration step
PMC:4886883Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">The refractive outcome of Toric Lentis Mplus implant in cataract surgery</title>
<author><name sortKey="Chiam, Patrick J" sort="Chiam, Patrick J" uniqKey="Chiam P" first="Patrick J" last="Chiam">Patrick J. Chiam</name>
<affiliation wicri:level="1"><nlm:aff id="aff1"><addr-line>Birmingham and Midland Eye Centre, City Hospital, Birmingham BH18 7QH, United Kingdom</addr-line>
</nlm:aff>
<country xml:lang="fr">Royaume-Uni</country>
<wicri:regionArea>Birmingham and Midland Eye Centre, City Hospital, Birmingham BH18 7QH</wicri:regionArea>
<wicri:noRegion>Birmingham BH18 7QH</wicri:noRegion>
</affiliation>
</author>
<author><name sortKey="Quah, Say A" sort="Quah, Say A" uniqKey="Quah S" first="Say A" last="Quah">Say A. Quah</name>
<affiliation wicri:level="1"><nlm:aff id="aff2"><addr-line>Optegra Manchester Eye Hospital, Manchester M20 2EY, United Kingdom</addr-line>
</nlm:aff>
<country xml:lang="fr">Royaume-Uni</country>
<wicri:regionArea>Optegra Manchester Eye Hospital, Manchester M20 2EY</wicri:regionArea>
<wicri:noRegion>Manchester M20 2EY</wicri:noRegion>
</affiliation>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PMC</idno>
<idno type="pmc">4886883</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4886883</idno>
<idno type="RBID">PMC:4886883</idno>
<idno type="doi">10.18240/ijo.2016.05.10</idno>
<idno type="pmid">NONE</idno>
<date when="2016">2016</date>
<idno type="wicri:Area/Pmc/Corpus">000454</idno>
<idno type="wicri:Area/Pmc/Curation">000454</idno>
<idno type="wicri:Area/Pmc/Checkpoint">000021</idno>
<idno type="wicri:Area/Ncbi/Merge">004800</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en" level="a" type="main">The refractive outcome of Toric Lentis Mplus implant in cataract surgery</title>
<author><name sortKey="Chiam, Patrick J" sort="Chiam, Patrick J" uniqKey="Chiam P" first="Patrick J" last="Chiam">Patrick J. Chiam</name>
<affiliation wicri:level="1"><nlm:aff id="aff1"><addr-line>Birmingham and Midland Eye Centre, City Hospital, Birmingham BH18 7QH, United Kingdom</addr-line>
</nlm:aff>
<country xml:lang="fr">Royaume-Uni</country>
<wicri:regionArea>Birmingham and Midland Eye Centre, City Hospital, Birmingham BH18 7QH</wicri:regionArea>
<wicri:noRegion>Birmingham BH18 7QH</wicri:noRegion>
</affiliation>
</author>
<author><name sortKey="Quah, Say A" sort="Quah, Say A" uniqKey="Quah S" first="Say A" last="Quah">Say A. Quah</name>
<affiliation wicri:level="1"><nlm:aff id="aff2"><addr-line>Optegra Manchester Eye Hospital, Manchester M20 2EY, United Kingdom</addr-line>
</nlm:aff>
<country xml:lang="fr">Royaume-Uni</country>
<wicri:regionArea>Optegra Manchester Eye Hospital, Manchester M20 2EY</wicri:regionArea>
<wicri:noRegion>Manchester M20 2EY</wicri:noRegion>
</affiliation>
</author>
</analytic>
<series><title level="j">International Journal of Ophthalmology</title>
<idno type="ISSN">2222-3959</idno>
<idno type="eISSN">2227-4898</idno>
<imprint><date when="2016">2016</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass></textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en"><sec><title>AIM</title>
<p>To evaluate the refractive outcome of Toric Lentis Mplus intraocular lens (IOL) implant.</p>
</sec>
<sec><title>METHODS</title>
<p>This is a retrospective case series. Consecutive patients with corneal astigmatism of at least 1.5 D had Toric Lentis Mplus IOL implant during cataract surgery. The exclusion criteria included irregular astigmatism on corneal topography, large scotopic pupil diameter (>6 mm), poor visual potential and significant ocular comorbidity. Postoperative manifest refraction, uncorrected distance visual acuity (UDVA), best-corrected distance visual acuity (BCVA), uncorrected intermediate visual acuity (UIVA) at 3/4 m and uncorrected near visual acuity (UNVA) were obtained.</p>
</sec>
<sec><title>RESULTS</title>
<p>There were 70 eyes from 49 patients in this study. Patients were refracted at a median of 8.9wk (range 4.0 to 15.5) from the operation date. Sixty-five percent of eyes had 6/7.5 (0.10 logMAR) or better, and 99% 6/12 (0.30 logMAR) or better postoperative UDVA. Eighty-nine percent could read Jaeger (J) 3 (0.28 logMAR) and 95% J5 (0.37 logMAR) at 40 cm. The median magnitude of astigmatism decreased from 1.91 D to 0.49 D (Wilcoxon, <italic>P</italic>
<0.001) after the operation. The range of the cylindrical error was reduced from 1.5-3.95 D (keratometric) preoperatively to 0.00-1.46 D (subjective refraction transposed to corneal plane) postoperatively.</p>
</sec>
<sec><title>CONCLUSION</title>
<p>Toric Lentis Mplus IOL has good predictability in reducing preexisting corneal astigmatism.</p>
</sec>
</div>
</front>
</TEI>
<pmc article-type="research-article"><pmc-comment>The publisher of this article does not allow downloading of the full text in XML form.</pmc-comment>
<front><journal-meta><journal-id journal-id-type="nlm-ta">Int J Ophthalmol</journal-id>
<journal-id journal-id-type="iso-abbrev">Int J Ophthalmol</journal-id>
<journal-id journal-id-type="publisher-id">IJO</journal-id>
<journal-title-group><journal-title>International Journal of Ophthalmology</journal-title>
</journal-title-group>
<issn pub-type="ppub">2222-3959</issn>
<issn pub-type="epub">2227-4898</issn>
<publisher><publisher-name>International Journal of Ophthalmology Press</publisher-name>
</publisher>
</journal-meta>
<article-meta><article-id pub-id-type="pmc">4886883</article-id>
<article-id pub-id-type="publisher-id">ijo-09-05-699</article-id>
<article-id pub-id-type="doi">10.18240/ijo.2016.05.10</article-id>
<article-categories><subj-group subj-group-type="heading"><subject>Clinical Research</subject>
</subj-group>
</article-categories>
<title-group><article-title>The refractive outcome of Toric Lentis Mplus implant in cataract surgery</article-title>
</title-group>
<contrib-group><contrib contrib-type="author"><name><surname>Chiam</surname>
<given-names>Patrick J</given-names>
</name>
<xref ref-type="aff" rid="aff1">1</xref>
</contrib>
<contrib contrib-type="author"><name><surname>Quah</surname>
<given-names>Say A</given-names>
</name>
<xref ref-type="aff" rid="aff2">2</xref>
</contrib>
</contrib-group>
<aff id="aff1"><label>1</label>
<addr-line>Birmingham and Midland Eye Centre, City Hospital, Birmingham BH18 7QH, United Kingdom</addr-line>
</aff>
<aff id="aff2"><label>2</label>
<addr-line>Optegra Manchester Eye Hospital, Manchester M20 2EY, United Kingdom</addr-line>
</aff>
<author-notes><corresp><bold>Correspondence to:</bold>
Patrick J Chiam. Birmingham and Midland Eye Centre, City Hospital, Dudley Road, Birmingham BH18 7QH, United Kingdom. <email>pjtchiam@yahoo.com</email>
</corresp>
</author-notes>
<pub-date pub-type="epub"><day>18</day>
<month>5</month>
<year>2016</year>
</pub-date>
<pub-date pub-type="collection"><year>2016</year>
</pub-date>
<volume>9</volume>
<issue>5</issue>
<fpage>699</fpage>
<lpage>702</lpage>
<history><date date-type="received"><day>20</day>
<month>9</month>
<year>2015</year>
</date>
<date date-type="accepted"><day>17</day>
<month>11</month>
<year>2015</year>
</date>
</history>
<permissions><copyright-statement>International Journal of Ophthalmology Press</copyright-statement>
<copyright-year>2016</copyright-year>
</permissions>
<abstract><sec><title>AIM</title>
<p>To evaluate the refractive outcome of Toric Lentis Mplus intraocular lens (IOL) implant.</p>
</sec>
<sec><title>METHODS</title>
<p>This is a retrospective case series. Consecutive patients with corneal astigmatism of at least 1.5 D had Toric Lentis Mplus IOL implant during cataract surgery. The exclusion criteria included irregular astigmatism on corneal topography, large scotopic pupil diameter (>6 mm), poor visual potential and significant ocular comorbidity. Postoperative manifest refraction, uncorrected distance visual acuity (UDVA), best-corrected distance visual acuity (BCVA), uncorrected intermediate visual acuity (UIVA) at 3/4 m and uncorrected near visual acuity (UNVA) were obtained.</p>
</sec>
<sec><title>RESULTS</title>
<p>There were 70 eyes from 49 patients in this study. Patients were refracted at a median of 8.9wk (range 4.0 to 15.5) from the operation date. Sixty-five percent of eyes had 6/7.5 (0.10 logMAR) or better, and 99% 6/12 (0.30 logMAR) or better postoperative UDVA. Eighty-nine percent could read Jaeger (J) 3 (0.28 logMAR) and 95% J5 (0.37 logMAR) at 40 cm. The median magnitude of astigmatism decreased from 1.91 D to 0.49 D (Wilcoxon, <italic>P</italic>
<0.001) after the operation. The range of the cylindrical error was reduced from 1.5-3.95 D (keratometric) preoperatively to 0.00-1.46 D (subjective refraction transposed to corneal plane) postoperatively.</p>
</sec>
<sec><title>CONCLUSION</title>
<p>Toric Lentis Mplus IOL has good predictability in reducing preexisting corneal astigmatism.</p>
</sec>
</abstract>
<kwd-group><kwd>Toric Lentis Mplus</kwd>
<kwd>multi-focal intraocular lens implant</kwd>
<kwd>refractive outcome</kwd>
</kwd-group>
</article-meta>
</front>
</pmc>
<affiliations><list><country><li>Royaume-Uni</li>
</country>
</list>
<tree><country name="Royaume-Uni"><noRegion><name sortKey="Chiam, Patrick J" sort="Chiam, Patrick J" uniqKey="Chiam P" first="Patrick J" last="Chiam">Patrick J. Chiam</name>
</noRegion>
<name sortKey="Quah, Say A" sort="Quah, Say A" uniqKey="Quah S" first="Say A" last="Quah">Say A. Quah</name>
</country>
</tree>
</affiliations>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Ncbi/Merge
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 004800 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Ncbi/Merge/biblio.hfd -nk 004800 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Ticri/CIDE |area= HapticV1 |flux= Ncbi |étape= Merge |type= RBID |clé= PMC:4886883 |texte= The refractive outcome of Toric Lentis Mplus implant in cataract surgery }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/Ncbi/Merge/RBID.i -Sk "pubmed:NONE" \ | HfdSelect -Kh $EXPLOR_AREA/Data/Ncbi/Merge/biblio.hfd \ | NlmPubMed2Wicri -a HapticV1
![]() | This area was generated with Dilib version V0.6.23. | ![]() |