Dose response of CaF2:Tm to charged particles of different LET.

Auteurs : M F Moyers [États-Unis] ; G A Nelson

Source :

RBID : pubmed:19746804

Descripteurs français

English descriptors

Abstract

Thermoluminescent dosimeters are well established for performing calibrations in radiotherapy and for monitoring dose to personnel exposed to low linear energy transfer (LET) ionizing radiation. Patients undergoing light ion therapy and astronauts engaged in space flight are, however, exposed to radiation fields consisting of a mix of low- and high-LET charged particles. In this study, glow curves from CaF2:Tm chips were examined after exposure to various electron and ion beams. The annealing and readout procedures for these chips were optimized for these beams. After a 10 min prereadout annealing at 100 degrees C, the optimized glow curve samples the light output between 95 and 335 degrees C with a heating rate of 2 degrees C/s. The ratio of the integral of the glow curve under peaks 4-6 to the integral under peak 3 was approximately 0.9 for electrons, 1.0 for entrance protons, 1.6 for peak protons, and 2.2 for entrance carbon, silicon, and iron ions. The integral light output per unit dose in water for the iron exposures was about half as much as for the electron exposures. The peak-area-ratio can be used to determine a dose response factor for different LET radiations.

DOI: 10.1118/1.3159758
PubMed: 19746804


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Dose response of CaF2:Tm to charged particles of different LET.</title>
<author>
<name sortKey="Moyers, M F" sort="Moyers, M F" uniqKey="Moyers M" first="M F" last="Moyers">M F Moyers</name>
<affiliation wicri:level="1">
<nlm:affiliation>Loma Linda University, Loma Linda, California 92354, USA. mfmoyers@roadrunner.com</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Loma Linda University, Loma Linda, California 92354</wicri:regionArea>
<wicri:noRegion>California 92354</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Nelson, G A" sort="Nelson, G A" uniqKey="Nelson G" first="G A" last="Nelson">G A Nelson</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2009">2009</date>
<idno type="RBID">pubmed:19746804</idno>
<idno type="pmid">19746804</idno>
<idno type="doi">10.1118/1.3159758</idno>
<idno type="wicri:Area/PubMed/Corpus">000518</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">000518</idno>
<idno type="wicri:Area/PubMed/Curation">000518</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">000518</idno>
<idno type="wicri:Area/PubMed/Checkpoint">000518</idno>
<idno type="wicri:explorRef" wicri:stream="Checkpoint" wicri:step="PubMed">000518</idno>
<idno type="wicri:Area/Ncbi/Merge">000325</idno>
<idno type="wicri:Area/Ncbi/Curation">000325</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">000325</idno>
<idno type="wicri:doubleKey">0094-2405:2009:Moyers M:dose:response:of</idno>
<idno type="wicri:Area/Main/Merge">000F67</idno>
<idno type="wicri:Area/Main/Curation">000F49</idno>
<idno type="wicri:Area/Main/Exploration">000F49</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Dose response of CaF2:Tm to charged particles of different LET.</title>
<author>
<name sortKey="Moyers, M F" sort="Moyers, M F" uniqKey="Moyers M" first="M F" last="Moyers">M F Moyers</name>
<affiliation wicri:level="1">
<nlm:affiliation>Loma Linda University, Loma Linda, California 92354, USA. mfmoyers@roadrunner.com</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Loma Linda University, Loma Linda, California 92354</wicri:regionArea>
<wicri:noRegion>California 92354</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Nelson, G A" sort="Nelson, G A" uniqKey="Nelson G" first="G A" last="Nelson">G A Nelson</name>
</author>
</analytic>
<series>
<title level="j">Medical physics</title>
<idno type="ISSN">0094-2405</idno>
<imprint>
<date when="2009" type="published">2009</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Calcium Fluoride (chemistry)</term>
<term>Dose-Response Relationship, Radiation</term>
<term>Humans</term>
<term>Linear Energy Transfer</term>
<term>Phantoms, Imaging</term>
<term>Radiation Dosage</term>
<term>Thulium (chemistry)</term>
<term>Water</term>
</keywords>
<keywords scheme="KwdFr" xml:lang="fr">
<term>Dose de radiation</term>
<term>Eau</term>
<term>Fantômes en imagerie</term>
<term>Fluorure de calcium ()</term>
<term>Humains</term>
<term>Relation dose-effet des radiations</term>
<term>Thulium ()</term>
<term>Transfert linéique d'énergie</term>
</keywords>
<keywords scheme="MESH" type="chemical" qualifier="chemistry" xml:lang="en">
<term>Calcium Fluoride</term>
<term>Thulium</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Dose-Response Relationship, Radiation</term>
<term>Humans</term>
<term>Linear Energy Transfer</term>
<term>Phantoms, Imaging</term>
<term>Radiation Dosage</term>
<term>Water</term>
</keywords>
<keywords scheme="MESH" xml:lang="fr">
<term>Dose de radiation</term>
<term>Eau</term>
<term>Fantômes en imagerie</term>
<term>Fluorure de calcium</term>
<term>Humains</term>
<term>Relation dose-effet des radiations</term>
<term>Thulium</term>
<term>Transfert linéique d'énergie</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Thermoluminescent dosimeters are well established for performing calibrations in radiotherapy and for monitoring dose to personnel exposed to low linear energy transfer (LET) ionizing radiation. Patients undergoing light ion therapy and astronauts engaged in space flight are, however, exposed to radiation fields consisting of a mix of low- and high-LET charged particles. In this study, glow curves from CaF2:Tm chips were examined after exposure to various electron and ion beams. The annealing and readout procedures for these chips were optimized for these beams. After a 10 min prereadout annealing at 100 degrees C, the optimized glow curve samples the light output between 95 and 335 degrees C with a heating rate of 2 degrees C/s. The ratio of the integral of the glow curve under peaks 4-6 to the integral under peak 3 was approximately 0.9 for electrons, 1.0 for entrance protons, 1.6 for peak protons, and 2.2 for entrance carbon, silicon, and iron ions. The integral light output per unit dose in water for the iron exposures was about half as much as for the electron exposures. The peak-area-ratio can be used to determine a dose response factor for different LET radiations.</div>
</front>
</TEI>
<affiliations>
<list>
<country>
<li>États-Unis</li>
</country>
</list>
<tree>
<noCountry>
<name sortKey="Nelson, G A" sort="Nelson, G A" uniqKey="Nelson G" first="G A" last="Nelson">G A Nelson</name>
</noCountry>
<country name="États-Unis">
<noRegion>
<name sortKey="Moyers, M F" sort="Moyers, M F" uniqKey="Moyers M" first="M F" last="Moyers">M F Moyers</name>
</noRegion>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Terre/explor/ThuliumV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000F49 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 000F49 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Terre
   |area=    ThuliumV1
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     pubmed:19746804
   |texte=   Dose response of CaF2:Tm to charged particles of different LET.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Exploration/RBID.i   -Sk "pubmed:19746804" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd   \
       | NlmPubMed2Wicri -a ThuliumV1 

Wicri

This area was generated with Dilib version V0.6.21.
Data generation: Thu May 12 08:27:09 2016. Site generation: Thu Mar 7 22:33:44 2024