Serveur d'exploration sur le patient édenté

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

The influence of resilient liner and clip attachments for bar‐implant‐retained mandibular overdentures on opposing maxillary ridge. A 5‐year randomised clinical trial

Identifieur interne : 001E10 ( Main/Exploration ); précédent : 001E09; suivant : 001E11

The influence of resilient liner and clip attachments for bar‐implant‐retained mandibular overdentures on opposing maxillary ridge. A 5‐year randomised clinical trial

Auteurs : M. A. Elsyad [Égypte] ; T. M. Ashmawy [Égypte] ; A. G. Faramawy [Égypte]

Source :

RBID : ISTEX:DE798E73CAFBC4A60091ACD0BCF6D9780730F893

Descripteurs français

English descriptors

Abstract

This study aimed to compare the influence of resilient liner and clip attachments for bar‐implant‐retained mandibular overdentures on opposing maxillary ridge after 5 years of denture wearing. Thirty edentulous male patients (mean age 62·5 years) received two implants in the anterior mandible after being allocated into two equal groups using balanced randomisation. After 3 months, implants were connected with resilient bars. New maxillary complete dentures were then constructed, and mandibular overdentures were retained to the bars with either clips (group I, GI) or silicone resilient liners (group II, GII). The prosthetic and soft tissue complications of the maxillary dentures were recorded 6 months (T6 m), 1 year (T1), 3 years (T3) and 5 years (T5) after overdenture insertion. Traced rotational tomograms were used for measurements of maxillary alveolar bone loss. The proportional value between bone areas and areas of reference not subject to resorption was expressed as a ratio (R). Change in R immediately before (T0) and after 5 years (T5) of overdenture insertion was calculated. Maxillary denture relining times and frequency of flabby anterior maxillary ridge occurred significantly more often in GI compared with GII. The change of R in anterior part of maxilla was significantly higher than change of R in posterior part in both groups. GI showed significant resorption of anterior residual ridge compared with GII. Relining times and frequencies of flabby ridge were significantly correlated with change in R. Within the limitations of this study, resilient liner attachments for bar‐implant‐retained mandibular overdentures are associated with decreased resorption and flabbiness of maxillary anterior residual ridge and fewer maxillary denture relining times when compared with clip attachments.

Url:
DOI: 10.1111/joor.12120


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI wicri:istexFullTextTei="biblStruct">
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">The influence of resilient liner and clip attachments for bar‐implant‐retained mandibular overdentures on opposing maxillary ridge. A 5‐year randomised clinical trial</title>
<author>
<name sortKey="Elsyad, M A" sort="Elsyad, M A" uniqKey="Elsyad M" first="M. A." last="Elsyad">M. A. Elsyad</name>
</author>
<author>
<name sortKey="Ashmawy, T M" sort="Ashmawy, T M" uniqKey="Ashmawy T" first="T. M." last="Ashmawy">T. M. Ashmawy</name>
</author>
<author>
<name sortKey="Faramawy, A G" sort="Faramawy, A G" uniqKey="Faramawy A" first="A. G." last="Faramawy">A. G. Faramawy</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:DE798E73CAFBC4A60091ACD0BCF6D9780730F893</idno>
<date when="2014" year="2014">2014</date>
<idno type="doi">10.1111/joor.12120</idno>
<idno type="url">https://api.istex.fr/document/DE798E73CAFBC4A60091ACD0BCF6D9780730F893/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">006E63</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Corpus" wicri:corpus="ISTEX">006E63</idno>
<idno type="wicri:Area/Istex/Curation">006E63</idno>
<idno type="wicri:Area/Istex/Checkpoint">000020</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Checkpoint">000020</idno>
<idno type="wicri:doubleKey">0305-182X:2014:Elsyad M:the:influence:of</idno>
<idno type="wicri:source">PubMed</idno>
<idno type="RBID">pubmed:24354686</idno>
<idno type="wicri:Area/PubMed/Corpus">000A39</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">000A39</idno>
<idno type="wicri:Area/PubMed/Curation">000A39</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">000A39</idno>
<idno type="wicri:Area/PubMed/Checkpoint">000A39</idno>
<idno type="wicri:explorRef" wicri:stream="Checkpoint" wicri:step="PubMed">000A39</idno>
<idno type="wicri:Area/Ncbi/Merge">004C44</idno>
<idno type="wicri:Area/Ncbi/Curation">004C44</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">004C44</idno>
<idno type="wicri:Area/Main/Merge">001E17</idno>
<idno type="wicri:Area/Main/Curation">001E10</idno>
<idno type="wicri:Area/Main/Exploration">001E10</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title level="a" type="main">The influence of resilient liner and clip attachments for bar‐implant‐retained mandibular overdentures on opposing maxillary ridge. A 5‐year randomised clinical trial</title>
<author>
<name sortKey="Elsyad, M A" sort="Elsyad, M A" uniqKey="Elsyad M" first="M. A." last="Elsyad">M. A. Elsyad</name>
<affiliation wicri:level="1">
<country xml:lang="fr">Égypte</country>
<wicri:regionArea>Department of Removable Prosthodontics, Faculty of Dentistry, Mansoura University, Mansoura</wicri:regionArea>
<wicri:noRegion>Mansoura</wicri:noRegion>
</affiliation>
<affiliation></affiliation>
<affiliation wicri:level="1">
<country wicri:rule="url">Égypte</country>
</affiliation>
</author>
<author>
<name sortKey="Ashmawy, T M" sort="Ashmawy, T M" uniqKey="Ashmawy T" first="T. M." last="Ashmawy">T. M. Ashmawy</name>
<affiliation wicri:level="1">
<country xml:lang="fr">Égypte</country>
<wicri:regionArea>Department of Maxillofacial Prosthodontics, National Cancer Institute, Cairo University, Cairo</wicri:regionArea>
<wicri:noRegion>Cairo</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Faramawy, A G" sort="Faramawy, A G" uniqKey="Faramawy A" first="A. G." last="Faramawy">A. G. Faramawy</name>
<affiliation wicri:level="1">
<country xml:lang="fr">Égypte</country>
<wicri:regionArea>Department of Removable Prosthodontics, Faculty of Dentistry, Mansoura University, Mansoura</wicri:regionArea>
<wicri:noRegion>Mansoura</wicri:noRegion>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series>
<title level="j" type="main">Journal of Oral Rehabilitation</title>
<title level="j" type="alt">JOURNAL OF ORAL REHABILITATION</title>
<idno type="ISSN">0305-182X</idno>
<idno type="eISSN">1365-2842</idno>
<imprint>
<biblScope unit="vol">41</biblScope>
<biblScope unit="issue">1</biblScope>
<biblScope unit="page" from="69">69</biblScope>
<biblScope unit="page" to="77">77</biblScope>
<biblScope unit="page-count">9</biblScope>
<date type="published" when="2014-01">2014-01</date>
</imprint>
<idno type="ISSN">0305-182X</idno>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt>
<idno type="ISSN">0305-182X</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Aged</term>
<term>Alveolar Bone Loss</term>
<term>Dental Prosthesis, Implant-Supported (adverse effects)</term>
<term>Denture Design</term>
<term>Denture, Complete, Lower</term>
<term>Denture, Overlay (adverse effects)</term>
<term>Humans</term>
<term>Jaw, Edentulous (pathology)</term>
<term>Male</term>
<term>Mandible (pathology)</term>
<term>Maxilla (pathology)</term>
<term>Middle Aged</term>
<term>Patient Satisfaction</term>
<term>Treatment Outcome</term>
</keywords>
<keywords scheme="KwdFr" xml:lang="fr">
<term>Adulte d'âge moyen</term>
<term>Conception d'appareil de prothèse dentaire</term>
<term>Humains</term>
<term>Mandibule (anatomopathologie)</term>
<term>Maxillaire (anatomopathologie)</term>
<term>Mâchoire édentée (anatomopathologie)</term>
<term>Mâle</term>
<term>Overdenture (effets indésirables)</term>
<term>Prothèse dentaire complète inférieure</term>
<term>Prothèse dentaire implanto-portée (effets indésirables)</term>
<term>Résorption alvéolaire</term>
<term>Résultat thérapeutique</term>
<term>Satisfaction du patient</term>
<term>Sujet âgé</term>
</keywords>
<keywords scheme="MESH" qualifier="adverse effects" xml:lang="en">
<term>Dental Prosthesis, Implant-Supported</term>
<term>Denture, Overlay</term>
</keywords>
<keywords scheme="MESH" qualifier="anatomopathologie" xml:lang="fr">
<term>Mandibule</term>
<term>Maxillaire</term>
<term>Mâchoire édentée</term>
</keywords>
<keywords scheme="MESH" qualifier="effets indésirables" xml:lang="fr">
<term>Overdenture</term>
<term>Prothèse dentaire implanto-portée</term>
</keywords>
<keywords scheme="MESH" qualifier="pathology" xml:lang="en">
<term>Jaw, Edentulous</term>
<term>Mandible</term>
<term>Maxilla</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Aged</term>
<term>Alveolar Bone Loss</term>
<term>Denture Design</term>
<term>Denture, Complete, Lower</term>
<term>Humans</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Patient Satisfaction</term>
<term>Treatment Outcome</term>
</keywords>
<keywords scheme="MESH" xml:lang="fr">
<term>Adulte d'âge moyen</term>
<term>Conception d'appareil de prothèse dentaire</term>
<term>Humains</term>
<term>Mâle</term>
<term>Prothèse dentaire complète inférieure</term>
<term>Résorption alvéolaire</term>
<term>Résultat thérapeutique</term>
<term>Satisfaction du patient</term>
<term>Sujet âgé</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract">This study aimed to compare the influence of resilient liner and clip attachments for bar‐implant‐retained mandibular overdentures on opposing maxillary ridge after 5 years of denture wearing. Thirty edentulous male patients (mean age 62·5 years) received two implants in the anterior mandible after being allocated into two equal groups using balanced randomisation. After 3 months, implants were connected with resilient bars. New maxillary complete dentures were then constructed, and mandibular overdentures were retained to the bars with either clips (group I, GI) or silicone resilient liners (group II, GII). The prosthetic and soft tissue complications of the maxillary dentures were recorded 6 months (T6 m), 1 year (T1), 3 years (T3) and 5 years (T5) after overdenture insertion. Traced rotational tomograms were used for measurements of maxillary alveolar bone loss. The proportional value between bone areas and areas of reference not subject to resorption was expressed as a ratio (R). Change in R immediately before (T0) and after 5 years (T5) of overdenture insertion was calculated. Maxillary denture relining times and frequency of flabby anterior maxillary ridge occurred significantly more often in GI compared with GII. The change of R in anterior part of maxilla was significantly higher than change of R in posterior part in both groups. GI showed significant resorption of anterior residual ridge compared with GII. Relining times and frequencies of flabby ridge were significantly correlated with change in R. Within the limitations of this study, resilient liner attachments for bar‐implant‐retained mandibular overdentures are associated with decreased resorption and flabbiness of maxillary anterior residual ridge and fewer maxillary denture relining times when compared with clip attachments.</div>
</front>
</TEI>
<affiliations>
<list>
<country>
<li>Égypte</li>
</country>
</list>
<tree>
<country name="Égypte">
<noRegion>
<name sortKey="Elsyad, M A" sort="Elsyad, M A" uniqKey="Elsyad M" first="M. A." last="Elsyad">M. A. Elsyad</name>
</noRegion>
<name sortKey="Ashmawy, T M" sort="Ashmawy, T M" uniqKey="Ashmawy T" first="T. M." last="Ashmawy">T. M. Ashmawy</name>
<name sortKey="Elsyad, M A" sort="Elsyad, M A" uniqKey="Elsyad M" first="M. A." last="Elsyad">M. A. Elsyad</name>
<name sortKey="Faramawy, A G" sort="Faramawy, A G" uniqKey="Faramawy A" first="A. G." last="Faramawy">A. G. Faramawy</name>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001E10 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 001E10 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     ISTEX:DE798E73CAFBC4A60091ACD0BCF6D9780730F893
   |texte=   The influence of resilient liner and clip attachments for bar‐implant‐retained mandibular overdentures on opposing maxillary ridge. A 5‐year randomised clinical trial
}}

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022