Implant supported overdentures — the Copenhagen experience
Identifieur interne : 004854 ( Istex/Checkpoint ); précédent : 004853; suivant : 004855Implant supported overdentures — the Copenhagen experience
Auteurs : Klaus Gotfredsen [Danemark]Source :
- Journal of Dentistry [ 0300-5712 ] ; 1997.
English descriptors
- KwdEn :
- Abutment, Abutment connection, Astra, Astra tech implants, Attachment, Ball attachment, Ball attachments, Biological effect, Denture, Edentulous mandible, Elsevier science, Fracture, Hyperplasia, Implant, Implant abutment, Implants, Marginal bone height, Masseter muscle, Matrix, Osseointegrated implants, Other studies, Overdenture, Overdenture group, Overdenture treatment, Overdentures, Present study, Prosthesis, Prosthesis group, Technical complications, Upper denture, Year observation period.
- Teeft :
- Abutment, Abutment connection, Astra, Astra tech implants, Ball attachment, Ball attachments, Biological effect, Denture, Edentulous mandible, Elsevier science, Fracture, Hyperplasia, Implant, Implant abutment, Marginal bone height, Masseter muscle, Matrix, Osseointegrated implants, Other studies, Overdenture, Overdenture group, Overdenture treatment, Overdentures, Present study, Prosthesis, Prosthesis group, Technical complications, Upper denture, Year observation period.
Abstract
Abstract: Objetives: To evaluate the functional and biological effect of implant-supported overdenture treatment in the lower jaw.Methds and Materials: Thirty two patients were consecutively treated with Astra Tech implants in the lower jaw for retaining overdentures. All implants had a diameter of 3.5 mm and all but two of the implants were longer than 10 mm. For the implant supported overdentures two methods of attachment were used, a bar or a ball.Results: One of 69 fixtures was lost during the 4–5 year observation period. The mean bone loss for all fixtures was less than 0.2 mm per year. Complications included 15 fractures of the ball attachment and 26 episodes of looseness of the matrices holding the screw in place. Patient satisfaction with the treatment of the lower jaw was high although 7 patients found that control of the upper denture was poor following treatment.Conclusions: When the bone quality and quantity is sufficient, two implants can support an overdenture in the lower jaw, providing prosthesis which functions well.
Url:
DOI: 10.1016/S0300-5712(97)87699-3
Affiliations:
Links toward previous steps (curation, corpus...)
Links to Exploration step
ISTEX:891F448F6FF8FC8B734644ABC8F7CD6ECFC40BABLe document en format XML
<record><TEI wicri:istexFullTextTei="biblStruct"><teiHeader><fileDesc><titleStmt><title xml:lang="en">Implant supported overdentures — the Copenhagen experience</title>
<author><name sortKey="Gotfredsen, Klaus" sort="Gotfredsen, Klaus" uniqKey="Gotfredsen K" first="Klaus" last="Gotfredsen">Klaus Gotfredsen</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:891F448F6FF8FC8B734644ABC8F7CD6ECFC40BAB</idno>
<date when="1997" year="1997">1997</date>
<idno type="doi">10.1016/S0300-5712(97)87699-3</idno>
<idno type="url">https://api.istex.fr/document/891F448F6FF8FC8B734644ABC8F7CD6ECFC40BAB/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">004417</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Corpus" wicri:corpus="ISTEX">004417</idno>
<idno type="wicri:Area/Istex/Curation">004417</idno>
<idno type="wicri:Area/Istex/Checkpoint">004854</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Checkpoint">004854</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title level="a" type="main" xml:lang="en">Implant supported overdentures — the Copenhagen experience</title>
<author><name sortKey="Gotfredsen, Klaus" sort="Gotfredsen, Klaus" uniqKey="Gotfredsen K" first="Klaus" last="Gotfredsen">Klaus Gotfredsen</name>
<affiliation wicri:level="3"><country xml:lang="fr">Danemark</country>
<wicri:regionArea>Department of Prosthetic Dentistry, University of Copenhagen, Copenhagen</wicri:regionArea>
<placeName><settlement type="city">Copenhague</settlement>
<region type="région" nuts="2">Hovedstaden</region>
</placeName>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series><title level="j">Journal of Dentistry</title>
<title level="j" type="abbrev">JJOD</title>
<idno type="ISSN">0300-5712</idno>
<imprint><publisher>ELSEVIER</publisher>
<date type="published" when="1997">1997</date>
<biblScope unit="volume">25</biblScope>
<biblScope unit="supplement">I1</biblScope>
<biblScope unit="page" from="S39">S39</biblScope>
<biblScope unit="page" to="S42">S42</biblScope>
</imprint>
<idno type="ISSN">0300-5712</idno>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt><idno type="ISSN">0300-5712</idno>
</seriesStmt>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Abutment</term>
<term>Abutment connection</term>
<term>Astra</term>
<term>Astra tech implants</term>
<term>Attachment</term>
<term>Ball attachment</term>
<term>Ball attachments</term>
<term>Biological effect</term>
<term>Denture</term>
<term>Edentulous mandible</term>
<term>Elsevier science</term>
<term>Fracture</term>
<term>Hyperplasia</term>
<term>Implant</term>
<term>Implant abutment</term>
<term>Implants</term>
<term>Marginal bone height</term>
<term>Masseter muscle</term>
<term>Matrix</term>
<term>Osseointegrated implants</term>
<term>Other studies</term>
<term>Overdenture</term>
<term>Overdenture group</term>
<term>Overdenture treatment</term>
<term>Overdentures</term>
<term>Present study</term>
<term>Prosthesis</term>
<term>Prosthesis group</term>
<term>Technical complications</term>
<term>Upper denture</term>
<term>Year observation period</term>
</keywords>
<keywords scheme="Teeft" xml:lang="en"><term>Abutment</term>
<term>Abutment connection</term>
<term>Astra</term>
<term>Astra tech implants</term>
<term>Ball attachment</term>
<term>Ball attachments</term>
<term>Biological effect</term>
<term>Denture</term>
<term>Edentulous mandible</term>
<term>Elsevier science</term>
<term>Fracture</term>
<term>Hyperplasia</term>
<term>Implant</term>
<term>Implant abutment</term>
<term>Marginal bone height</term>
<term>Masseter muscle</term>
<term>Matrix</term>
<term>Osseointegrated implants</term>
<term>Other studies</term>
<term>Overdenture</term>
<term>Overdenture group</term>
<term>Overdenture treatment</term>
<term>Overdentures</term>
<term>Present study</term>
<term>Prosthesis</term>
<term>Prosthesis group</term>
<term>Technical complications</term>
<term>Upper denture</term>
<term>Year observation period</term>
</keywords>
</textClass>
<langUsage><language ident="en">en</language>
</langUsage>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">Abstract: Objetives: To evaluate the functional and biological effect of implant-supported overdenture treatment in the lower jaw.Methds and Materials: Thirty two patients were consecutively treated with Astra Tech implants in the lower jaw for retaining overdentures. All implants had a diameter of 3.5 mm and all but two of the implants were longer than 10 mm. For the implant supported overdentures two methods of attachment were used, a bar or a ball.Results: One of 69 fixtures was lost during the 4–5 year observation period. The mean bone loss for all fixtures was less than 0.2 mm per year. Complications included 15 fractures of the ball attachment and 26 episodes of looseness of the matrices holding the screw in place. Patient satisfaction with the treatment of the lower jaw was high although 7 patients found that control of the upper denture was poor following treatment.Conclusions: When the bone quality and quantity is sufficient, two implants can support an overdenture in the lower jaw, providing prosthesis which functions well.</div>
</front>
</TEI>
<affiliations><list><country><li>Danemark</li>
</country>
<region><li>Hovedstaden</li>
</region>
<settlement><li>Copenhague</li>
</settlement>
</list>
<tree><country name="Danemark"><region name="Hovedstaden"><name sortKey="Gotfredsen, Klaus" sort="Gotfredsen, Klaus" uniqKey="Gotfredsen K" first="Klaus" last="Gotfredsen">Klaus Gotfredsen</name>
</region>
</country>
</tree>
</affiliations>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Istex/Checkpoint
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 004854 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Istex/Checkpoint/biblio.hfd -nk 004854 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Santé |area= EdenteV2 |flux= Istex |étape= Checkpoint |type= RBID |clé= ISTEX:891F448F6FF8FC8B734644ABC8F7CD6ECFC40BAB |texte= Implant supported overdentures — the Copenhagen experience }}
![]() | This area was generated with Dilib version V0.6.32. | ![]() |