Trial of a disc lens for intercapsular cataract extraction
Identifieur interne : 009781 ( Main/Exploration ); précédent : 009780; suivant : 009782Trial of a disc lens for intercapsular cataract extraction
Auteurs : David G. Kent [Nouvelle-Zélande] ; Keith A. Gross [Nouvelle-Zélande]Source :
- Australian and New Zealand Journal of Ophthalmology [ 0814-9763 ] ; 1990-08.
English descriptors
- KwdEn :
- Adolescent, Adult, Aged, Aged, 80 and over, Cataract Extraction (methods), Cataract extraction, Female, Follow-Up Studies, Humans, Lens Capsule, Crystalline (surgery), Lenses, Intraocular, Male, Methylmethacrylates, Middle Aged, Optics and Photonics, Pupil, Random Allocation, Refraction, Ocular, Visual Acuity, intraocular., lenses.
- MESH :
- chemical : Methylmethacrylates.
- methods : Cataract Extraction.
- surgery : Lens Capsule, Crystalline.
- Adolescent, Adult, Aged, Aged, 80 and over, Female, Follow-Up Studies, Humans, Lenses, Intraocular, Male, Middle Aged, Optics and Photonics, Pupil, Random Allocation, Refraction, Ocular, Visual Acuity.
Abstract
The preliminary results are presented of a prospective trial of a new ‘disc’ intraocular lens. (Pharmacia Model CD801 A). Forty‐four lenses were implanted into the capsular bag using an intercapsular cataract extraction technique. The lens is a one‐piece all‐polymethylmeth‐acrylate (PMMA) lens with a 6 mm biconvex optic. The optic sits within a 9 mm diameter flexible PMMA ring. Two haptic stalks link this flexible haptic ring to the optic. The lens was assessed for its ease of insertion, its rate of decentration, the incidence of posterior capsular opacity and its effects on pupillary function. Results of the trial at three months follow‐up are presented. They show that the lens is easy to insert into the capsular bag even through small pupils. It is very easy to dial, placing no stress on the bag when doing so. The incidence of decentration of 1 mm or greater was 5%, and the incidence of posterior capsular fibrosis at three months was 2%. As predicted, the lens sits well back in the eye, clear of the pupil.
Url:
DOI: 10.1111/j.1442-9071.1990.tb00629.x
Affiliations:
Links toward previous steps (curation, corpus...)
- to stream Istex, to step Corpus: 001E11
- to stream Istex, to step Curation: 001E11
- to stream Istex, to step Checkpoint: 004675
- to stream Main, to step Merge: 00A223
- to stream PubMed, to step Corpus: 002231
- to stream PubMed, to step Curation: 002231
- to stream PubMed, to step Checkpoint: 001F55
- to stream Ncbi, to step Merge: 002034
- to stream Ncbi, to step Curation: 002034
- to stream Ncbi, to step Checkpoint: 002034
- to stream Main, to step Merge: 00A167
- to stream Main, to step Curation: 009781
Le document en format XML
<record><TEI wicri:istexFullTextTei="biblStruct"><teiHeader><fileDesc><titleStmt><title xml:lang="en">Trial of a disc lens for intercapsular cataract extraction</title>
<author><name sortKey="Kent, David G" sort="Kent, David G" uniqKey="Kent D" first="David G." last="Kent">David G. Kent</name>
</author>
<author><name sortKey="Gross, Keith A" sort="Gross, Keith A" uniqKey="Gross K" first="Keith A." last="Gross">Keith A. Gross</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:A9F0EABB7D37E6AC87C944858B077351F5914E4C</idno>
<date when="1990" year="1990">1990</date>
<idno type="doi">10.1111/j.1442-9071.1990.tb00629.x</idno>
<idno type="url">https://api.istex.fr/document/A9F0EABB7D37E6AC87C944858B077351F5914E4C/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">001E11</idno>
<idno type="wicri:Area/Istex/Curation">001E11</idno>
<idno type="wicri:Area/Istex/Checkpoint">004675</idno>
<idno type="wicri:doubleKey">0814-9763:1990:Kent D:trial:of:a</idno>
<idno type="wicri:Area/Main/Merge">00A223</idno>
<idno type="wicri:source">PubMed</idno>
<idno type="RBID">pubmed:2261182</idno>
<idno type="wicri:Area/PubMed/Corpus">002231</idno>
<idno type="wicri:Area/PubMed/Curation">002231</idno>
<idno type="wicri:Area/PubMed/Checkpoint">001F55</idno>
<idno type="wicri:Area/Ncbi/Merge">002034</idno>
<idno type="wicri:Area/Ncbi/Curation">002034</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">002034</idno>
<idno type="wicri:doubleKey">0814-9763:1990:Kent D:trial:of:a</idno>
<idno type="wicri:Area/Main/Merge">00A167</idno>
<idno type="wicri:Area/Main/Curation">009781</idno>
<idno type="wicri:Area/Main/Exploration">009781</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title level="a" type="main" xml:lang="en">Trial of a disc lens for intercapsular cataract extraction</title>
<author><name sortKey="Kent, David G" sort="Kent, David G" uniqKey="Kent D" first="David G." last="Kent">David G. Kent</name>
<affiliation wicri:level="1"><country xml:lang="fr">Nouvelle-Zélande</country>
<wicri:regionArea>Ophthalmology Registrar, Waikato Public Hospital, Hamilton</wicri:regionArea>
<wicri:noRegion>Hamilton</wicri:noRegion>
</affiliation>
</author>
<author><name sortKey="Gross, Keith A" sort="Gross, Keith A" uniqKey="Gross K" first="Keith A." last="Gross">Keith A. Gross</name>
<affiliation wicri:level="1"><country xml:lang="fr">Nouvelle-Zélande</country>
<wicri:regionArea>Ophthalmologist, Waikato Public Hospital, Hamilton</wicri:regionArea>
<wicri:noRegion>Hamilton</wicri:noRegion>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series><title level="j">Australian and New Zealand Journal of Ophthalmology</title>
<idno type="ISSN">0814-9763</idno>
<idno type="eISSN">1440-1606</idno>
<imprint><publisher>Blackwell Publishing Ltd</publisher>
<pubPlace>Oxford, UK</pubPlace>
<date type="published" when="1990-08">1990-08</date>
<biblScope unit="volume">18</biblScope>
<biblScope unit="issue">3</biblScope>
<biblScope unit="page" from="329">329</biblScope>
<biblScope unit="page" to="334">334</biblScope>
</imprint>
<idno type="ISSN">0814-9763</idno>
</series>
<idno type="istex">A9F0EABB7D37E6AC87C944858B077351F5914E4C</idno>
<idno type="DOI">10.1111/j.1442-9071.1990.tb00629.x</idno>
<idno type="ArticleID">CEO329</idno>
</biblStruct>
</sourceDesc>
<seriesStmt><idno type="ISSN">0814-9763</idno>
</seriesStmt>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Adolescent</term>
<term>Adult</term>
<term>Aged</term>
<term>Aged, 80 and over</term>
<term>Cataract Extraction (methods)</term>
<term>Cataract extraction</term>
<term>Female</term>
<term>Follow-Up Studies</term>
<term>Humans</term>
<term>Lens Capsule, Crystalline (surgery)</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Methylmethacrylates</term>
<term>Middle Aged</term>
<term>Optics and Photonics</term>
<term>Pupil</term>
<term>Random Allocation</term>
<term>Refraction, Ocular</term>
<term>Visual Acuity</term>
<term>intraocular.</term>
<term>lenses</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en"><term>Methylmethacrylates</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en"><term>Cataract Extraction</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en"><term>Lens Capsule, Crystalline</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Adolescent</term>
<term>Adult</term>
<term>Aged</term>
<term>Aged, 80 and over</term>
<term>Female</term>
<term>Follow-Up Studies</term>
<term>Humans</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Optics and Photonics</term>
<term>Pupil</term>
<term>Random Allocation</term>
<term>Refraction, Ocular</term>
<term>Visual Acuity</term>
</keywords>
</textClass>
<langUsage><language ident="en">en</language>
</langUsage>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">The preliminary results are presented of a prospective trial of a new ‘disc’ intraocular lens. (Pharmacia Model CD801 A). Forty‐four lenses were implanted into the capsular bag using an intercapsular cataract extraction technique. The lens is a one‐piece all‐polymethylmeth‐acrylate (PMMA) lens with a 6 mm biconvex optic. The optic sits within a 9 mm diameter flexible PMMA ring. Two haptic stalks link this flexible haptic ring to the optic. The lens was assessed for its ease of insertion, its rate of decentration, the incidence of posterior capsular opacity and its effects on pupillary function. Results of the trial at three months follow‐up are presented. They show that the lens is easy to insert into the capsular bag even through small pupils. It is very easy to dial, placing no stress on the bag when doing so. The incidence of decentration of 1 mm or greater was 5%, and the incidence of posterior capsular fibrosis at three months was 2%. As predicted, the lens sits well back in the eye, clear of the pupil.</div>
</front>
</TEI>
<affiliations><list><country><li>Nouvelle-Zélande</li>
</country>
</list>
<tree><country name="Nouvelle-Zélande"><noRegion><name sortKey="Kent, David G" sort="Kent, David G" uniqKey="Kent D" first="David G." last="Kent">David G. Kent</name>
</noRegion>
<name sortKey="Gross, Keith A" sort="Gross, Keith A" uniqKey="Gross K" first="Keith A." last="Gross">Keith A. Gross</name>
</country>
</tree>
</affiliations>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 009781 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 009781 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Ticri/CIDE |area= HapticV1 |flux= Main |étape= Exploration |type= RBID |clé= ISTEX:A9F0EABB7D37E6AC87C944858B077351F5914E4C |texte= Trial of a disc lens for intercapsular cataract extraction }}
This area was generated with Dilib version V0.6.23. |