Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Trial of a disc lens for intercapsular cataract extraction.

Identifieur interne : 002034 ( Ncbi/Merge ); précédent : 002033; suivant : 002035

Trial of a disc lens for intercapsular cataract extraction.

Auteurs : D G Kent [Nouvelle-Zélande] ; K A Gross

Source :

RBID : pubmed:2261182

English descriptors

Abstract

The preliminary results are presented of a prospective trial of a new 'disc' intraocular lens. (Pharmacia Model CD801A). Forty-four lenses were implanted into the capsular bag using an intercapsular cataract extraction technique. The lens is a one-piece all-polymethylmethacrylate (PMMA) lens with a 6 mm biconvex optic. The optic sits within a 9 mm diameter flexible PMMA ring. Two haptic stalks link this flexible haptic ring to the optic. The lens was assessed for its ease of insertion, its rate of decentration, the incidence of posterior capsular opacity and its effects on pupillary function. Results of the trial at three months follow-up are presented. They show that the lens is easy to insert into the capsular bag even through small pupils. It is very easy to dial, placing no stress on the bag when doing so. The incidence of decentration of 1 mm or greater was 5%, and the incidence of posterior capsular fibrosis at three months was 2%. As predicted, the lens sits well back in the eye, clear of the pupil.

PubMed: 2261182

Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:2261182

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Trial of a disc lens for intercapsular cataract extraction.</title>
<author>
<name sortKey="Kent, D G" sort="Kent, D G" uniqKey="Kent D" first="D G" last="Kent">D G Kent</name>
<affiliation wicri:level="1">
<nlm:affiliation>Ophthalmology Registrar, Waikato Public Hospital, Hamilton, New Zealand.</nlm:affiliation>
<country xml:lang="fr">Nouvelle-Zélande</country>
<wicri:regionArea>Ophthalmology Registrar, Waikato Public Hospital, Hamilton</wicri:regionArea>
<wicri:noRegion>Hamilton</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Gross, K A" sort="Gross, K A" uniqKey="Gross K" first="K A" last="Gross">K A Gross</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="1990">1990</date>
<idno type="RBID">pubmed:2261182</idno>
<idno type="pmid">2261182</idno>
<idno type="wicri:Area/PubMed/Corpus">002231</idno>
<idno type="wicri:Area/PubMed/Curation">002231</idno>
<idno type="wicri:Area/PubMed/Checkpoint">001F55</idno>
<idno type="wicri:Area/Ncbi/Merge">002034</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Trial of a disc lens for intercapsular cataract extraction.</title>
<author>
<name sortKey="Kent, D G" sort="Kent, D G" uniqKey="Kent D" first="D G" last="Kent">D G Kent</name>
<affiliation wicri:level="1">
<nlm:affiliation>Ophthalmology Registrar, Waikato Public Hospital, Hamilton, New Zealand.</nlm:affiliation>
<country xml:lang="fr">Nouvelle-Zélande</country>
<wicri:regionArea>Ophthalmology Registrar, Waikato Public Hospital, Hamilton</wicri:regionArea>
<wicri:noRegion>Hamilton</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Gross, K A" sort="Gross, K A" uniqKey="Gross K" first="K A" last="Gross">K A Gross</name>
</author>
</analytic>
<series>
<title level="j">Australian and New Zealand journal of ophthalmology</title>
<idno type="ISSN">0814-9763</idno>
<imprint>
<date when="1990" type="published">1990</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Adolescent</term>
<term>Adult</term>
<term>Aged</term>
<term>Aged, 80 and over</term>
<term>Cataract Extraction (methods)</term>
<term>Female</term>
<term>Follow-Up Studies</term>
<term>Humans</term>
<term>Lens Capsule, Crystalline (surgery)</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Methylmethacrylates</term>
<term>Middle Aged</term>
<term>Optics and Photonics</term>
<term>Pupil</term>
<term>Random Allocation</term>
<term>Refraction, Ocular</term>
<term>Visual Acuity</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en">
<term>Methylmethacrylates</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en">
<term>Cataract Extraction</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en">
<term>Lens Capsule, Crystalline</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Adolescent</term>
<term>Adult</term>
<term>Aged</term>
<term>Aged, 80 and over</term>
<term>Female</term>
<term>Follow-Up Studies</term>
<term>Humans</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Optics and Photonics</term>
<term>Pupil</term>
<term>Random Allocation</term>
<term>Refraction, Ocular</term>
<term>Visual Acuity</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">The preliminary results are presented of a prospective trial of a new 'disc' intraocular lens. (Pharmacia Model CD801A). Forty-four lenses were implanted into the capsular bag using an intercapsular cataract extraction technique. The lens is a one-piece all-polymethylmethacrylate (PMMA) lens with a 6 mm biconvex optic. The optic sits within a 9 mm diameter flexible PMMA ring. Two haptic stalks link this flexible haptic ring to the optic. The lens was assessed for its ease of insertion, its rate of decentration, the incidence of posterior capsular opacity and its effects on pupillary function. Results of the trial at three months follow-up are presented. They show that the lens is easy to insert into the capsular bag even through small pupils. It is very easy to dial, placing no stress on the bag when doing so. The incidence of decentration of 1 mm or greater was 5%, and the incidence of posterior capsular fibrosis at three months was 2%. As predicted, the lens sits well back in the eye, clear of the pupil.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="MEDLINE">
<PMID Version="1">2261182</PMID>
<DateCreated>
<Year>1991</Year>
<Month>02</Month>
<Day>07</Day>
</DateCreated>
<DateCompleted>
<Year>1991</Year>
<Month>02</Month>
<Day>07</Day>
</DateCompleted>
<DateRevised>
<Year>2008</Year>
<Month>11</Month>
<Day>21</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">0814-9763</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>18</Volume>
<Issue>3</Issue>
<PubDate>
<Year>1990</Year>
<Month>Aug</Month>
</PubDate>
</JournalIssue>
<Title>Australian and New Zealand journal of ophthalmology</Title>
<ISOAbbreviation>Aust N Z J Ophthalmol</ISOAbbreviation>
</Journal>
<ArticleTitle>Trial of a disc lens for intercapsular cataract extraction.</ArticleTitle>
<Pagination>
<MedlinePgn>329-34</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText>The preliminary results are presented of a prospective trial of a new 'disc' intraocular lens. (Pharmacia Model CD801A). Forty-four lenses were implanted into the capsular bag using an intercapsular cataract extraction technique. The lens is a one-piece all-polymethylmethacrylate (PMMA) lens with a 6 mm biconvex optic. The optic sits within a 9 mm diameter flexible PMMA ring. Two haptic stalks link this flexible haptic ring to the optic. The lens was assessed for its ease of insertion, its rate of decentration, the incidence of posterior capsular opacity and its effects on pupillary function. Results of the trial at three months follow-up are presented. They show that the lens is easy to insert into the capsular bag even through small pupils. It is very easy to dial, placing no stress on the bag when doing so. The incidence of decentration of 1 mm or greater was 5%, and the incidence of posterior capsular fibrosis at three months was 2%. As predicted, the lens sits well back in the eye, clear of the pupil.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Kent</LastName>
<ForeName>D G</ForeName>
<Initials>DG</Initials>
<AffiliationInfo>
<Affiliation>Ophthalmology Registrar, Waikato Public Hospital, Hamilton, New Zealand.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Gross</LastName>
<ForeName>K A</ForeName>
<Initials>KA</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016430">Clinical Trial</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>AUSTRALIA</Country>
<MedlineTA>Aust N Z J Ophthalmol</MedlineTA>
<NlmUniqueID>8505423</NlmUniqueID>
<ISSNLinking>0814-9763</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D008768">Methylmethacrylates</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000293">Adolescent</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000328">Adult</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000368">Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000369">Aged, 80 and over</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D002387">Cataract Extraction</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000379">methods</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D005260">Female</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D005500">Follow-Up Studies</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D007903">Lens Capsule, Crystalline</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000601">surgery</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D007910">Lenses, Intraocular</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D008297">Male</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D008768">Methylmethacrylates</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D008875">Middle Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D055095">Optics and Photonics</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D011680">Pupil</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D011897">Random Allocation</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D012029">Refraction, Ocular</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D014792">Visual Acuity</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="pubmed">
<Year>1990</Year>
<Month>8</Month>
<Day>1</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>1990</Year>
<Month>8</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>1</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>1990</Year>
<Month>8</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">2261182</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
<affiliations>
<list>
<country>
<li>Nouvelle-Zélande</li>
</country>
</list>
<tree>
<noCountry>
<name sortKey="Gross, K A" sort="Gross, K A" uniqKey="Gross K" first="K A" last="Gross">K A Gross</name>
</noCountry>
<country name="Nouvelle-Zélande">
<noRegion>
<name sortKey="Kent, D G" sort="Kent, D G" uniqKey="Kent D" first="D G" last="Kent">D G Kent</name>
</noRegion>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Ncbi/Merge
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 002034 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Ncbi/Merge/biblio.hfd -nk 002034 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Ncbi
   |étape=   Merge
   |type=    RBID
   |clé=     pubmed:2261182
   |texte=   Trial of a disc lens for intercapsular cataract extraction.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Ncbi/Merge/RBID.i   -Sk "pubmed:2261182" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Ncbi/Merge/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024