Trial of a disc lens for intercapsular cataract extraction
Identifieur interne : 001E11 ( Istex/Curation ); précédent : 001E10; suivant : 001E12Trial of a disc lens for intercapsular cataract extraction
Auteurs : David G. Kent [Nouvelle-Zélande] ; Keith A. Gross [Nouvelle-Zélande]Source :
- Australian and New Zealand Journal of Ophthalmology [ 0814-9763 ] ; 1990-08.
English descriptors
- KwdEn :
Abstract
The preliminary results are presented of a prospective trial of a new ‘disc’ intraocular lens. (Pharmacia Model CD801 A). Forty‐four lenses were implanted into the capsular bag using an intercapsular cataract extraction technique. The lens is a one‐piece all‐polymethylmeth‐acrylate (PMMA) lens with a 6 mm biconvex optic. The optic sits within a 9 mm diameter flexible PMMA ring. Two haptic stalks link this flexible haptic ring to the optic. The lens was assessed for its ease of insertion, its rate of decentration, the incidence of posterior capsular opacity and its effects on pupillary function. Results of the trial at three months follow‐up are presented. They show that the lens is easy to insert into the capsular bag even through small pupils. It is very easy to dial, placing no stress on the bag when doing so. The incidence of decentration of 1 mm or greater was 5%, and the incidence of posterior capsular fibrosis at three months was 2%. As predicted, the lens sits well back in the eye, clear of the pupil.
Url:
DOI: 10.1111/j.1442-9071.1990.tb00629.x
Links toward previous steps (curation, corpus...)
- to stream Istex, to step Corpus: Pour aller vers cette notice dans l'étape Curation :001E11
Links to Exploration step
ISTEX:A9F0EABB7D37E6AC87C944858B077351F5914E4CLe document en format XML
<record><TEI wicri:istexFullTextTei="biblStruct"><teiHeader><fileDesc><titleStmt><title xml:lang="en">Trial of a disc lens for intercapsular cataract extraction</title>
<author><name sortKey="Kent, David G" sort="Kent, David G" uniqKey="Kent D" first="David G." last="Kent">David G. Kent</name>
<affiliation wicri:level="1"><mods:affiliation>Ophthalmology Registrar, Waikato Public Hospital, Hamilton, New Zealand</mods:affiliation>
<country xml:lang="fr">Nouvelle-Zélande</country>
<wicri:regionArea>Ophthalmology Registrar, Waikato Public Hospital, Hamilton</wicri:regionArea>
</affiliation>
</author>
<author><name sortKey="Gross, Keith A" sort="Gross, Keith A" uniqKey="Gross K" first="Keith A." last="Gross">Keith A. Gross</name>
<affiliation wicri:level="1"><mods:affiliation>Ophthalmologist, Waikato Public Hospital, Hamilton, New Zealand</mods:affiliation>
<country xml:lang="fr">Nouvelle-Zélande</country>
<wicri:regionArea>Ophthalmologist, Waikato Public Hospital, Hamilton</wicri:regionArea>
</affiliation>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:A9F0EABB7D37E6AC87C944858B077351F5914E4C</idno>
<date when="1990" year="1990">1990</date>
<idno type="doi">10.1111/j.1442-9071.1990.tb00629.x</idno>
<idno type="url">https://api.istex.fr/document/A9F0EABB7D37E6AC87C944858B077351F5914E4C/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">001E11</idno>
<idno type="wicri:Area/Istex/Curation">001E11</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title level="a" type="main" xml:lang="en">Trial of a disc lens for intercapsular cataract extraction</title>
<author><name sortKey="Kent, David G" sort="Kent, David G" uniqKey="Kent D" first="David G." last="Kent">David G. Kent</name>
<affiliation wicri:level="1"><mods:affiliation>Ophthalmology Registrar, Waikato Public Hospital, Hamilton, New Zealand</mods:affiliation>
<country xml:lang="fr">Nouvelle-Zélande</country>
<wicri:regionArea>Ophthalmology Registrar, Waikato Public Hospital, Hamilton</wicri:regionArea>
</affiliation>
</author>
<author><name sortKey="Gross, Keith A" sort="Gross, Keith A" uniqKey="Gross K" first="Keith A." last="Gross">Keith A. Gross</name>
<affiliation wicri:level="1"><mods:affiliation>Ophthalmologist, Waikato Public Hospital, Hamilton, New Zealand</mods:affiliation>
<country xml:lang="fr">Nouvelle-Zélande</country>
<wicri:regionArea>Ophthalmologist, Waikato Public Hospital, Hamilton</wicri:regionArea>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series><title level="j">Australian and New Zealand Journal of Ophthalmology</title>
<idno type="ISSN">0814-9763</idno>
<idno type="eISSN">1440-1606</idno>
<imprint><publisher>Blackwell Publishing Ltd</publisher>
<pubPlace>Oxford, UK</pubPlace>
<date type="published" when="1990-08">1990-08</date>
<biblScope unit="volume">18</biblScope>
<biblScope unit="issue">3</biblScope>
<biblScope unit="page" from="329">329</biblScope>
<biblScope unit="page" to="334">334</biblScope>
</imprint>
<idno type="ISSN">0814-9763</idno>
</series>
<idno type="istex">A9F0EABB7D37E6AC87C944858B077351F5914E4C</idno>
<idno type="DOI">10.1111/j.1442-9071.1990.tb00629.x</idno>
<idno type="ArticleID">CEO329</idno>
</biblStruct>
</sourceDesc>
<seriesStmt><idno type="ISSN">0814-9763</idno>
</seriesStmt>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Cataract extraction</term>
<term>intraocular.</term>
<term>lenses</term>
</keywords>
</textClass>
<langUsage><language ident="en">en</language>
</langUsage>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">The preliminary results are presented of a prospective trial of a new ‘disc’ intraocular lens. (Pharmacia Model CD801 A). Forty‐four lenses were implanted into the capsular bag using an intercapsular cataract extraction technique. The lens is a one‐piece all‐polymethylmeth‐acrylate (PMMA) lens with a 6 mm biconvex optic. The optic sits within a 9 mm diameter flexible PMMA ring. Two haptic stalks link this flexible haptic ring to the optic. The lens was assessed for its ease of insertion, its rate of decentration, the incidence of posterior capsular opacity and its effects on pupillary function. Results of the trial at three months follow‐up are presented. They show that the lens is easy to insert into the capsular bag even through small pupils. It is very easy to dial, placing no stress on the bag when doing so. The incidence of decentration of 1 mm or greater was 5%, and the incidence of posterior capsular fibrosis at three months was 2%. As predicted, the lens sits well back in the eye, clear of the pupil.</div>
</front>
</TEI>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Istex/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001E11 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Istex/Curation/biblio.hfd -nk 001E11 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Ticri/CIDE |area= HapticV1 |flux= Istex |étape= Curation |type= RBID |clé= ISTEX:A9F0EABB7D37E6AC87C944858B077351F5914E4C |texte= Trial of a disc lens for intercapsular cataract extraction }}
This area was generated with Dilib version V0.6.23. |