Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

[Phacoemulsification in white cataract].

Identifieur interne : 001A99 ( PubMed/Curation ); précédent : 001A98; suivant : 001B00

[Phacoemulsification in white cataract].

Auteurs : Monica Gavri ; Diana Popa ; C. C R U ; E. Gusho ; Erzsebet Kantor

Source :

RBID : pubmed:15341105

English descriptors

Abstract

The study presents the technical difficulties of the capsulorhexis and phacoemulsification in the white, intumescent cataract and the incidences occurred during the foldable IOL implantation with the Monarch II injector.

PubMed: 15341105

Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:15341105

Curation

No country items

Monica Gavri
<affiliation>
<nlm:affiliation>Spitalul Militar de Urgenţă Dr. Constantin Papilian Cluj-Napoca.</nlm:affiliation>
<wicri:noCountry code="no comma">Spitalul Militar de Urgenţă Dr. Constantin Papilian Cluj-Napoca.</wicri:noCountry>
</affiliation>

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">[Phacoemulsification in white cataract].</title>
<author>
<name sortKey="Gavri, Monica" sort="Gavri, Monica" uniqKey="Gavri M" first="Monica" last="Gavri">Monica Gavri</name>
<affiliation>
<nlm:affiliation>Spitalul Militar de Urgenţă Dr. Constantin Papilian Cluj-Napoca.</nlm:affiliation>
<wicri:noCountry code="no comma">Spitalul Militar de Urgenţă Dr. Constantin Papilian Cluj-Napoca.</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Popa, Diana" sort="Popa, Diana" uniqKey="Popa D" first="Diana" last="Popa">Diana Popa</name>
</author>
<author>
<name sortKey="C R U, C" sort="C R U, C" uniqKey="C R U C" first="C" last="C R U">C. C R U</name>
</author>
<author>
<name sortKey="Gusho, E" sort="Gusho, E" uniqKey="Gusho E" first="E" last="Gusho">E. Gusho</name>
</author>
<author>
<name sortKey="Kantor, Erzsebet" sort="Kantor, Erzsebet" uniqKey="Kantor E" first="Erzsebet" last="Kantor">Erzsebet Kantor</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2004">2004</date>
<idno type="RBID">pubmed:15341105</idno>
<idno type="pmid">15341105</idno>
<idno type="wicri:Area/PubMed/Corpus">001A99</idno>
<idno type="wicri:Area/PubMed/Curation">001A99</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">[Phacoemulsification in white cataract].</title>
<author>
<name sortKey="Gavri, Monica" sort="Gavri, Monica" uniqKey="Gavri M" first="Monica" last="Gavri">Monica Gavri</name>
<affiliation>
<nlm:affiliation>Spitalul Militar de Urgenţă Dr. Constantin Papilian Cluj-Napoca.</nlm:affiliation>
<wicri:noCountry code="no comma">Spitalul Militar de Urgenţă Dr. Constantin Papilian Cluj-Napoca.</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Popa, Diana" sort="Popa, Diana" uniqKey="Popa D" first="Diana" last="Popa">Diana Popa</name>
</author>
<author>
<name sortKey="C R U, C" sort="C R U, C" uniqKey="C R U C" first="C" last="C R U">C. C R U</name>
</author>
<author>
<name sortKey="Gusho, E" sort="Gusho, E" uniqKey="Gusho E" first="E" last="Gusho">E. Gusho</name>
</author>
<author>
<name sortKey="Kantor, Erzsebet" sort="Kantor, Erzsebet" uniqKey="Kantor E" first="Erzsebet" last="Kantor">Erzsebet Kantor</name>
</author>
</analytic>
<series>
<title level="j">Oftalmologia (Bucharest, Romania : 1990)</title>
<idno type="ISSN">1220-0875</idno>
<imprint>
<date when="2004" type="published">2004</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Capsulorhexis</term>
<term>Cataract (pathology)</term>
<term>Humans</term>
<term>Lens Implantation, Intraocular</term>
<term>Phacoemulsification (instrumentation)</term>
<term>Retrospective Studies</term>
<term>Treatment Outcome</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en">
<term>Phacoemulsification</term>
</keywords>
<keywords scheme="MESH" qualifier="pathology" xml:lang="en">
<term>Cataract</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Capsulorhexis</term>
<term>Humans</term>
<term>Lens Implantation, Intraocular</term>
<term>Retrospective Studies</term>
<term>Treatment Outcome</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">The study presents the technical difficulties of the capsulorhexis and phacoemulsification in the white, intumescent cataract and the incidences occurred during the foldable IOL implantation with the Monarch II injector.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="MEDLINE">
<PMID Version="1">15341105</PMID>
<DateCreated>
<Year>2004</Year>
<Month>09</Month>
<Day>02</Day>
</DateCreated>
<DateCompleted>
<Year>2004</Year>
<Month>11</Month>
<Day>09</Day>
</DateCompleted>
<DateRevised>
<Year>2006</Year>
<Month>11</Month>
<Day>15</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">1220-0875</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>48</Volume>
<Issue>2</Issue>
<PubDate>
<Year>2004</Year>
</PubDate>
</JournalIssue>
<Title>Oftalmologia (Bucharest, Romania : 1990)</Title>
<ISOAbbreviation>Oftalmologia</ISOAbbreviation>
</Journal>
<ArticleTitle>[Phacoemulsification in white cataract].</ArticleTitle>
<Pagination>
<MedlinePgn>81-7</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText Label="PURPOSE" NlmCategory="OBJECTIVE">The study presents the technical difficulties of the capsulorhexis and phacoemulsification in the white, intumescent cataract and the incidences occurred during the foldable IOL implantation with the Monarch II injector.</AbstractText>
<AbstractText Label="METHODS" NlmCategory="METHODS">The clinical study comprises a number of 70 eyes with white intumescent cataract operated during 15 January-15 December 2003 by the same surgeon. The surgical intervention consisted of lens extraction by phacoemulsification with clear corneal incision, using the Monarch II injector for the foldable IOL implantation. In 56 eyes, the anterior capsule was stained with trypan blue.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">The intraoperative complications include: failed capsulorexis in 4 cases (5.71%), rupture of posterior capsule in 1 case (1.43%) and the conversion to classical extracapsular extraction in 3 cases (4.29%). IOL implantation was made with the help of the Monarch II injector in 67 cases (95.71%). The foldable IOL implantation in the bag was realised a single time in 44 cases (62.9%). We had the following incidences in the other cases: the upside down turning of the IOL during unfolding in 2 cases, the second haptic capture in the tunnel of the cartridge in 2 cases, the second haptic stucks outside or in the anterior chamber in 18 cases, the first haptic stays in the sulcus and the second one stays outside in 1 case.</AbstractText>
<AbstractText Label="CONCLUSIONS" NlmCategory="CONCLUSIONS">In eyes with 1 intumescent cataract we can perform the continuous curvilinear capsulorhexis using trypan blue, but also without staining the anterior capsule using mechanical or manual aspiration of the liquefied cortex and viscoelastic substances. The foldable intraocular lens implantation with the injector proves to be an easy and comfortable method after it has been practiced for a longer period of time if the right size of the cartridge is used.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Gavriş</LastName>
<ForeName>Monica</ForeName>
<Initials>M</Initials>
<AffiliationInfo>
<Affiliation>Spitalul Militar de Urgenţă Dr. Constantin Papilian Cluj-Napoca.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Popa</LastName>
<ForeName>Diana</ForeName>
<Initials>D</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Cărăuş</LastName>
<ForeName>C</ForeName>
<Initials>C</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Gusho</LastName>
<ForeName>E</ForeName>
<Initials>E</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Kantor</LastName>
<ForeName>Erzsebet</ForeName>
<Initials>E</Initials>
</Author>
</AuthorList>
<Language>rum</Language>
<PublicationTypeList>
<PublicationType UI="D004740">English Abstract</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
<VernacularTitle>Facoemulsificarea în cataracta albă, intumescentă.</VernacularTitle>
</Article>
<MedlineJournalInfo>
<Country>Romania</Country>
<MedlineTA>Oftalmologia</MedlineTA>
<NlmUniqueID>9111247</NlmUniqueID>
<ISSNLinking>1220-0875</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D019923">Capsulorhexis</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D002386">Cataract</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000473">pathology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D019654">Lens Implantation, Intraocular</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D018918">Phacoemulsification</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000295">instrumentation</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D012189">Retrospective Studies</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D016896">Treatment Outcome</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="pubmed">
<Year>2004</Year>
<Month>9</Month>
<Day>3</Day>
<Hour>5</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2004</Year>
<Month>11</Month>
<Day>13</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>2004</Year>
<Month>9</Month>
<Day>3</Day>
<Hour>5</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">15341105</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001A99 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd -nk 001A99 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    PubMed
   |étape=   Curation
   |type=    RBID
   |clé=     pubmed:15341105
   |texte=   [Phacoemulsification in white cataract].
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Curation/RBID.i   -Sk "pubmed:15341105" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024