Optimal folding axis for acrylic intraocular lenses

Auteurs : Kong T. Oh ; Kean T. Oh

Source :

RBID : Pascal:96-0369123

Descripteurs français

English descriptors

Abstract

Acrylic intraocular lenses (lOLs) are easier to insert than foldable lenses of other materials. In addition to material properties, the structure of acrylic lenses allows an optimal folding angle along the 10 to 4 o'clock axis. Folding the IOL along this axis simplifies the manipulation of the leading haptic during insertion and places the trailing haptic within the capsular bag before the folded optic is released.

Notice en format standard (ISO 2709)

Pour connaître la documentation sur le format Inist Standard.

pA  
A01 01  1    @0 0886-3350
A02 01      @0 JCSUEV
A03   1    @0 J. cataract refractive surg.
A05       @2 22
A06       @2 6
A08 01  1  ENG  @1 Optimal folding axis for acrylic intraocular lenses
A11 01  1    @1 OH (KONG T.)
A11 02  1    @1 OH (KEAN T.)
A14 01      @2 8110 Market Street, Boardman, Ohio 44512 @3 USA @Z 1 aut.
A20       @1 667-670
A21       @1 1996
A23 01      @0 ENG
A43 01      @1 INIST @2 20937 @5 354000063680480030
A44       @0 0000 @1 © 1996 INIST-CNRS. All rights reserved.
A45       @0 3 ref.
A47 01  1    @0 96-0369123
A60       @1 P
A61       @0 A
A64 01  1    @0 Journal of cataract and refractive surgery
A66 01      @0 USA
C01 01    ENG  @0 Acrylic intraocular lenses (lOLs) are easier to insert than foldable lenses of other materials. In addition to material properties, the structure of acrylic lenses allows an optimal folding angle along the 10 to 4 o'clock axis. Folding the IOL along this axis simplifies the manipulation of the leading haptic during insertion and places the trailing haptic within the capsular bag before the folded optic is released.
C02 01  X    @0 002B25B
C03 01  X  FRE  @0 Lentille intraoculaire @5 01
C03 01  X  ENG  @0 Intraocular lens @5 01
C03 01  X  SPA  @0 Lente intraocular @5 01
C03 02  X  FRE  @0 Méthacrylate de méthyle polymère @2 NK @5 04
C03 02  X  ENG  @0 Methyl methacrylate polymer @2 NK @5 04
C03 02  X  SPA  @0 Metacrilato de metilo polímero @2 NK @5 04
C03 03  X  FRE  @0 Biomatériau @5 05
C03 03  X  ENG  @0 Biomaterial @5 05
C03 03  X  SPA  @0 Biomaterial @5 05
C03 04  X  FRE  @0 Pliage @5 07
C03 04  X  ENG  @0 Folding @5 07
C03 04  X  SPA  @0 Doblado @5 07
C03 05  X  FRE  @0 Axe @5 08
C03 05  X  ENG  @0 Axis @5 08
C03 05  X  SPA  @0 Eje @5 08
C03 06  X  FRE  @0 Technique @5 10
C03 06  X  ENG  @0 Technique @5 10
C03 06  X  SPA  @0 Técnica @5 10
C03 07  X  FRE  @0 Implantation @5 11
C03 07  X  ENG  @0 Implantation @5 11
C03 07  X  SPA  @0 Implantación @5 11
C03 08  X  FRE  @0 Homme @5 13
C03 08  X  ENG  @0 Human @5 13
C03 08  X  SPA  @0 Hombre @5 13
C07 01  X  FRE  @0 Chirurgie @5 37
C07 01  X  ENG  @0 Surgery @5 37
C07 01  X  SPA  @0 Cirugía @5 37
N21       @1 253

Format Inist (serveur)

NO : PASCAL 96-0369123 INIST
ET : Optimal folding axis for acrylic intraocular lenses
AU : OH (KONG T.); OH (KEAN T.)
AF : 8110 Market Street, Boardman, Ohio 44512/Etats-Unis (1 aut.)
DT : Publication en série; Niveau analytique
SO : Journal of cataract and refractive surgery; ISSN 0886-3350; Coden JCSUEV; Etats-Unis; Da. 1996; Vol. 22; No. 6; Pp. 667-670; Bibl. 3 ref.
LA : Anglais
EA : Acrylic intraocular lenses (lOLs) are easier to insert than foldable lenses of other materials. In addition to material properties, the structure of acrylic lenses allows an optimal folding angle along the 10 to 4 o'clock axis. Folding the IOL along this axis simplifies the manipulation of the leading haptic during insertion and places the trailing haptic within the capsular bag before the folded optic is released.
CC : 002B25B
FD : Lentille intraoculaire; Méthacrylate de méthyle polymère; Biomatériau; Pliage; Axe; Technique; Implantation; Homme
FG : Chirurgie
ED : Intraocular lens; Methyl methacrylate polymer; Biomaterial; Folding; Axis; Technique; Implantation; Human
EG : Surgery
SD : Lente intraocular; Metacrilato de metilo polímero; Biomaterial; Doblado; Eje; Técnica; Implantación; Hombre
LO : INIST-20937.354000063680480030
ID : 96-0369123

Links to Exploration step

Pascal:96-0369123

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en" level="a">Optimal folding axis for acrylic intraocular lenses</title>
<author>
<name sortKey="Oh, Kong T" sort="Oh, Kong T" uniqKey="Oh K" first="Kong T." last="Oh">Kong T. Oh</name>
<affiliation>
<inist:fA14 i1="01">
<s2>8110 Market Street, Boardman, Ohio 44512</s2>
<s3>USA</s3>
<sZ>1 aut.</sZ>
</inist:fA14>
</affiliation>
</author>
<author>
<name sortKey="Oh, Kean T" sort="Oh, Kean T" uniqKey="Oh K" first="Kean T." last="Oh">Kean T. Oh</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">INIST</idno>
<idno type="inist">96-0369123</idno>
<date when="1996">1996</date>
<idno type="stanalyst">PASCAL 96-0369123 INIST</idno>
<idno type="RBID">Pascal:96-0369123</idno>
<idno type="wicri:Area/PascalFrancis/Corpus">001705</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a">Optimal folding axis for acrylic intraocular lenses</title>
<author>
<name sortKey="Oh, Kong T" sort="Oh, Kong T" uniqKey="Oh K" first="Kong T." last="Oh">Kong T. Oh</name>
<affiliation>
<inist:fA14 i1="01">
<s2>8110 Market Street, Boardman, Ohio 44512</s2>
<s3>USA</s3>
<sZ>1 aut.</sZ>
</inist:fA14>
</affiliation>
</author>
<author>
<name sortKey="Oh, Kean T" sort="Oh, Kean T" uniqKey="Oh K" first="Kean T." last="Oh">Kean T. Oh</name>
</author>
</analytic>
<series>
<title level="j" type="main">Journal of cataract and refractive surgery</title>
<title level="j" type="abbreviated">J. cataract refractive surg.</title>
<idno type="ISSN">0886-3350</idno>
<imprint>
<date when="1996">1996</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt>
<title level="j" type="main">Journal of cataract and refractive surgery</title>
<title level="j" type="abbreviated">J. cataract refractive surg.</title>
<idno type="ISSN">0886-3350</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Axis</term>
<term>Biomaterial</term>
<term>Folding</term>
<term>Human</term>
<term>Implantation</term>
<term>Intraocular lens</term>
<term>Methyl methacrylate polymer</term>
<term>Technique</term>
</keywords>
<keywords scheme="Pascal" xml:lang="fr">
<term>Lentille intraoculaire</term>
<term>Méthacrylate de méthyle polymère</term>
<term>Biomatériau</term>
<term>Pliage</term>
<term>Axe</term>
<term>Technique</term>
<term>Implantation</term>
<term>Homme</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Acrylic intraocular lenses (lOLs) are easier to insert than foldable lenses of other materials. In addition to material properties, the structure of acrylic lenses allows an optimal folding angle along the 10 to 4 o'clock axis. Folding the IOL along this axis simplifies the manipulation of the leading haptic during insertion and places the trailing haptic within the capsular bag before the folded optic is released.</div>
</front>
</TEI>
<inist>
<standard h6="B">
<pA>
<fA01 i1="01" i2="1">
<s0>0886-3350</s0>
</fA01>
<fA02 i1="01">
<s0>JCSUEV</s0>
</fA02>
<fA03 i2="1">
<s0>J. cataract refractive surg.</s0>
</fA03>
<fA05>
<s2>22</s2>
</fA05>
<fA06>
<s2>6</s2>
</fA06>
<fA08 i1="01" i2="1" l="ENG">
<s1>Optimal folding axis for acrylic intraocular lenses</s1>
</fA08>
<fA11 i1="01" i2="1">
<s1>OH (KONG T.)</s1>
</fA11>
<fA11 i1="02" i2="1">
<s1>OH (KEAN T.)</s1>
</fA11>
<fA14 i1="01">
<s2>8110 Market Street, Boardman, Ohio 44512</s2>
<s3>USA</s3>
<sZ>1 aut.</sZ>
</fA14>
<fA20>
<s1>667-670</s1>
</fA20>
<fA21>
<s1>1996</s1>
</fA21>
<fA23 i1="01">
<s0>ENG</s0>
</fA23>
<fA43 i1="01">
<s1>INIST</s1>
<s2>20937</s2>
<s5>354000063680480030</s5>
</fA43>
<fA44>
<s0>0000</s0>
<s1>© 1996 INIST-CNRS. All rights reserved.</s1>
</fA44>
<fA45>
<s0>3 ref.</s0>
</fA45>
<fA47 i1="01" i2="1">
<s0>96-0369123</s0>
</fA47>
<fA60>
<s1>P</s1>
</fA60>
<fA61>
<s0>A</s0>
</fA61>
<fA64 i1="01" i2="1">
<s0>Journal of cataract and refractive surgery</s0>
</fA64>
<fA66 i1="01">
<s0>USA</s0>
</fA66>
<fC01 i1="01" l="ENG">
<s0>Acrylic intraocular lenses (lOLs) are easier to insert than foldable lenses of other materials. In addition to material properties, the structure of acrylic lenses allows an optimal folding angle along the 10 to 4 o'clock axis. Folding the IOL along this axis simplifies the manipulation of the leading haptic during insertion and places the trailing haptic within the capsular bag before the folded optic is released.</s0>
</fC01>
<fC02 i1="01" i2="X">
<s0>002B25B</s0>
</fC02>
<fC03 i1="01" i2="X" l="FRE">
<s0>Lentille intraoculaire</s0>
<s5>01</s5>
</fC03>
<fC03 i1="01" i2="X" l="ENG">
<s0>Intraocular lens</s0>
<s5>01</s5>
</fC03>
<fC03 i1="01" i2="X" l="SPA">
<s0>Lente intraocular</s0>
<s5>01</s5>
</fC03>
<fC03 i1="02" i2="X" l="FRE">
<s0>Méthacrylate de méthyle polymère</s0>
<s2>NK</s2>
<s5>04</s5>
</fC03>
<fC03 i1="02" i2="X" l="ENG">
<s0>Methyl methacrylate polymer</s0>
<s2>NK</s2>
<s5>04</s5>
</fC03>
<fC03 i1="02" i2="X" l="SPA">
<s0>Metacrilato de metilo polímero</s0>
<s2>NK</s2>
<s5>04</s5>
</fC03>
<fC03 i1="03" i2="X" l="FRE">
<s0>Biomatériau</s0>
<s5>05</s5>
</fC03>
<fC03 i1="03" i2="X" l="ENG">
<s0>Biomaterial</s0>
<s5>05</s5>
</fC03>
<fC03 i1="03" i2="X" l="SPA">
<s0>Biomaterial</s0>
<s5>05</s5>
</fC03>
<fC03 i1="04" i2="X" l="FRE">
<s0>Pliage</s0>
<s5>07</s5>
</fC03>
<fC03 i1="04" i2="X" l="ENG">
<s0>Folding</s0>
<s5>07</s5>
</fC03>
<fC03 i1="04" i2="X" l="SPA">
<s0>Doblado</s0>
<s5>07</s5>
</fC03>
<fC03 i1="05" i2="X" l="FRE">
<s0>Axe</s0>
<s5>08</s5>
</fC03>
<fC03 i1="05" i2="X" l="ENG">
<s0>Axis</s0>
<s5>08</s5>
</fC03>
<fC03 i1="05" i2="X" l="SPA">
<s0>Eje</s0>
<s5>08</s5>
</fC03>
<fC03 i1="06" i2="X" l="FRE">
<s0>Technique</s0>
<s5>10</s5>
</fC03>
<fC03 i1="06" i2="X" l="ENG">
<s0>Technique</s0>
<s5>10</s5>
</fC03>
<fC03 i1="06" i2="X" l="SPA">
<s0>Técnica</s0>
<s5>10</s5>
</fC03>
<fC03 i1="07" i2="X" l="FRE">
<s0>Implantation</s0>
<s5>11</s5>
</fC03>
<fC03 i1="07" i2="X" l="ENG">
<s0>Implantation</s0>
<s5>11</s5>
</fC03>
<fC03 i1="07" i2="X" l="SPA">
<s0>Implantación</s0>
<s5>11</s5>
</fC03>
<fC03 i1="08" i2="X" l="FRE">
<s0>Homme</s0>
<s5>13</s5>
</fC03>
<fC03 i1="08" i2="X" l="ENG">
<s0>Human</s0>
<s5>13</s5>
</fC03>
<fC03 i1="08" i2="X" l="SPA">
<s0>Hombre</s0>
<s5>13</s5>
</fC03>
<fC07 i1="01" i2="X" l="FRE">
<s0>Chirurgie</s0>
<s5>37</s5>
</fC07>
<fC07 i1="01" i2="X" l="ENG">
<s0>Surgery</s0>
<s5>37</s5>
</fC07>
<fC07 i1="01" i2="X" l="SPA">
<s0>Cirugía</s0>
<s5>37</s5>
</fC07>
<fN21>
<s1>253</s1>
</fN21>
</pA>
</standard>
<server>
<NO>PASCAL 96-0369123 INIST</NO>
<ET>Optimal folding axis for acrylic intraocular lenses</ET>
<AU>OH (KONG T.); OH (KEAN T.)</AU>
<AF>8110 Market Street, Boardman, Ohio 44512/Etats-Unis (1 aut.)</AF>
<DT>Publication en série; Niveau analytique</DT>
<SO>Journal of cataract and refractive surgery; ISSN 0886-3350; Coden JCSUEV; Etats-Unis; Da. 1996; Vol. 22; No. 6; Pp. 667-670; Bibl. 3 ref.</SO>
<LA>Anglais</LA>
<EA>Acrylic intraocular lenses (lOLs) are easier to insert than foldable lenses of other materials. In addition to material properties, the structure of acrylic lenses allows an optimal folding angle along the 10 to 4 o'clock axis. Folding the IOL along this axis simplifies the manipulation of the leading haptic during insertion and places the trailing haptic within the capsular bag before the folded optic is released.</EA>
<CC>002B25B</CC>
<FD>Lentille intraoculaire; Méthacrylate de méthyle polymère; Biomatériau; Pliage; Axe; Technique; Implantation; Homme</FD>
<FG>Chirurgie</FG>
<ED>Intraocular lens; Methyl methacrylate polymer; Biomaterial; Folding; Axis; Technique; Implantation; Human</ED>
<EG>Surgery</EG>
<SD>Lente intraocular; Metacrilato de metilo polímero; Biomaterial; Doblado; Eje; Técnica; Implantación; Hombre</SD>
<LO>INIST-20937.354000063680480030</LO>
<ID>96-0369123</ID>
</server>
</inist>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PascalFrancis/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001705 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PascalFrancis/Corpus/biblio.hfd -nk 001705 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    PascalFrancis
   |étape=   Corpus
   |type=    RBID
   |clé=     Pascal:96-0369123
   |texte=   Optimal folding axis for acrylic intraocular lenses
}}

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024