Incision width after phacoemulsification with foldable intraocular lens implantation

Identifieur interne : 001496 ( PascalFrancis/Corpus ); précédent : 001495; suivant : 001497

Incision width after phacoemulsification with foldable intraocular lens implantation

Auteurs : N. Mamalis

Source :

RBID : Pascal:00-0125695

Descripteurs français

English descriptors

Abstract

Purpose: To determine the incision size after insertion of foldable intraocular lenses (lOLs) using both a forceps and injectors. Setting: Intermountain Ocular Research Center, Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. Methods: One hundred patients had phacoemulsification through a clear corneal wound. The incision width was measured before and after IOL implantation. A 3-piece silicone IOL and a 3-piece acrylic IOL (both with an optic diameter of 5.5 mm) were inserted using a forceps. A plate-haptic silicone lens and a 3-piece silicone lens with a 6.0 mm diameter optic were inserted using an injector. Results: The wound size in the group with the 3-piece silicone lens inserted with a forceps enlarged 4.4% (3.23 to 3.38 mm) in the low-power IOL group (15.0 to 20.0 diopters [D]) and 6.2% (3.24 to 3.44 mm) in the high-power IOL group (20.5 to 25.0 D). Similarly, the acrylic IOL wound enlarged 5% (3.21 to 3.37 mm) in the low-power IOL group and 6% (3.25 to 3.44 mm) in the high-power IOL group when a forceps was used. The 3-piece silicone and plate silicone lenses inserted using an injector enlarged the wound 3.2% and 3.3% (3.02 to 3.11 mm and 3.05 to 3.15 mm), respectively. There was no difference in the wound size with higher IOL powers in eyes with injected lenses. Conclusions: Clear corneal incisions enlarge after insertion of foldable lOLs in a predictable manner, with a forceps-inserted IOL enlarging the wound diameter more than lenses inserted with an injector. The forceps-inserted lens group also showed a difference in wound size related to IOL power.

Notice en format standard (ISO 2709)

Pour connaître la documentation sur le format Inist Standard.

pA  
A01 01  1    @0 0886-3350
A02 01      @0 JCSUEV
A03   1    @0 J. cataract refractive surg.
A05       @2 26
A06       @2 2
A08 01  1  ENG  @1 Incision width after phacoemulsification with foldable intraocular lens implantation
A11 01  1    @1 MAMALIS (N.)
A14 01      @1 John A. Moran Eye Center, University of Utah @2 Salt Lake City, Utah @3 USA @Z 1 aut.
A20       @1 237-241
A21       @1 2000
A23 01      @0 ENG
A43 01      @1 INIST @2 20937 @5 354000081903090100
A44       @0 0000 @1 © 2000 INIST-CNRS. All rights reserved.
A45       @0 13 ref.
A47 01  1    @0 00-0125695
A60       @1 P
A61       @0 A
A64 01  1    @0 Journal of cataract and refractive surgery
A66 01      @0 USA
C01 01    ENG  @0 Purpose: To determine the incision size after insertion of foldable intraocular lenses (lOLs) using both a forceps and injectors. Setting: Intermountain Ocular Research Center, Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. Methods: One hundred patients had phacoemulsification through a clear corneal wound. The incision width was measured before and after IOL implantation. A 3-piece silicone IOL and a 3-piece acrylic IOL (both with an optic diameter of 5.5 mm) were inserted using a forceps. A plate-haptic silicone lens and a 3-piece silicone lens with a 6.0 mm diameter optic were inserted using an injector. Results: The wound size in the group with the 3-piece silicone lens inserted with a forceps enlarged 4.4% (3.23 to 3.38 mm) in the low-power IOL group (15.0 to 20.0 diopters [D]) and 6.2% (3.24 to 3.44 mm) in the high-power IOL group (20.5 to 25.0 D). Similarly, the acrylic IOL wound enlarged 5% (3.21 to 3.37 mm) in the low-power IOL group and 6% (3.25 to 3.44 mm) in the high-power IOL group when a forceps was used. The 3-piece silicone and plate silicone lenses inserted using an injector enlarged the wound 3.2% and 3.3% (3.02 to 3.11 mm and 3.05 to 3.15 mm), respectively. There was no difference in the wound size with higher IOL powers in eyes with injected lenses. Conclusions: Clear corneal incisions enlarge after insertion of foldable lOLs in a predictable manner, with a forceps-inserted IOL enlarging the wound diameter more than lenses inserted with an injector. The forceps-inserted lens group also showed a difference in wound size related to IOL power.
C02 01  X    @0 002B25B
C03 01  X  FRE  @0 Phacoémulsification @5 01
C03 01  X  ENG  @0 Phacoemulsification @5 01
C03 01  X  SPA  @0 Facoemulsificación @5 01
C03 02  X  FRE  @0 Cristallin @5 02
C03 02  X  ENG  @0 Lens @5 02
C03 02  X  SPA  @0 Cristalino @5 02
C03 03  X  FRE  @0 Oeil @5 03
C03 03  X  ENG  @0 Eye @5 03
C03 03  X  SPA  @0 Ojo @5 03
C03 04  X  FRE  @0 Lentille intraoculaire @5 04
C03 04  X  ENG  @0 Intraocular lens @5 04
C03 04  X  SPA  @0 Lente intraocular @5 04
C03 05  X  FRE  @0 Implantation @5 05
C03 05  X  ENG  @0 Implantation @5 05
C03 05  X  SPA  @0 Implantación @5 05
C03 06  X  FRE  @0 Incision chirurgicale @5 07
C03 06  X  ENG  @0 Surgical incision @5 07
C03 06  X  SPA  @0 Incisión quirúrgica @5 07
C03 07  X  FRE  @0 Taille @5 08
C03 07  X  ENG  @0 Size @5 08
C03 07  X  SPA  @0 Talla @5 08
C03 08  X  FRE  @0 Homme @5 10
C03 08  X  ENG  @0 Human @5 10
C03 08  X  SPA  @0 Hombre @5 10
C07 01  X  FRE  @0 Chirurgie @5 37
C07 01  X  ENG  @0 Surgery @5 37
C07 01  X  SPA  @0 Cirugía @5 37
N21       @1 094

Format Inist (serveur)

NO : PASCAL 00-0125695 INIST
ET : Incision width after phacoemulsification with foldable intraocular lens implantation
AU : MAMALIS (N.)
AF : John A. Moran Eye Center, University of Utah/Salt Lake City, Utah/Etats-Unis (1 aut.)
DT : Publication en série; Niveau analytique
SO : Journal of cataract and refractive surgery; ISSN 0886-3350; Coden JCSUEV; Etats-Unis; Da. 2000; Vol. 26; No. 2; Pp. 237-241; Bibl. 13 ref.
LA : Anglais
EA : Purpose: To determine the incision size after insertion of foldable intraocular lenses (lOLs) using both a forceps and injectors. Setting: Intermountain Ocular Research Center, Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. Methods: One hundred patients had phacoemulsification through a clear corneal wound. The incision width was measured before and after IOL implantation. A 3-piece silicone IOL and a 3-piece acrylic IOL (both with an optic diameter of 5.5 mm) were inserted using a forceps. A plate-haptic silicone lens and a 3-piece silicone lens with a 6.0 mm diameter optic were inserted using an injector. Results: The wound size in the group with the 3-piece silicone lens inserted with a forceps enlarged 4.4% (3.23 to 3.38 mm) in the low-power IOL group (15.0 to 20.0 diopters [D]) and 6.2% (3.24 to 3.44 mm) in the high-power IOL group (20.5 to 25.0 D). Similarly, the acrylic IOL wound enlarged 5% (3.21 to 3.37 mm) in the low-power IOL group and 6% (3.25 to 3.44 mm) in the high-power IOL group when a forceps was used. The 3-piece silicone and plate silicone lenses inserted using an injector enlarged the wound 3.2% and 3.3% (3.02 to 3.11 mm and 3.05 to 3.15 mm), respectively. There was no difference in the wound size with higher IOL powers in eyes with injected lenses. Conclusions: Clear corneal incisions enlarge after insertion of foldable lOLs in a predictable manner, with a forceps-inserted IOL enlarging the wound diameter more than lenses inserted with an injector. The forceps-inserted lens group also showed a difference in wound size related to IOL power.
CC : 002B25B
FD : Phacoémulsification; Cristallin; Oeil; Lentille intraoculaire; Implantation; Incision chirurgicale; Taille; Homme
FG : Chirurgie
ED : Phacoemulsification; Lens; Eye; Intraocular lens; Implantation; Surgical incision; Size; Human
EG : Surgery
SD : Facoemulsificación; Cristalino; Ojo; Lente intraocular; Implantación; Incisión quirúrgica; Talla; Hombre
LO : INIST-20937.354000081903090100
ID : 00-0125695

Links to Exploration step

Pascal:00-0125695

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en" level="a">Incision width after phacoemulsification with foldable intraocular lens implantation</title>
<author>
<name sortKey="Mamalis, N" sort="Mamalis, N" uniqKey="Mamalis N" first="N." last="Mamalis">N. Mamalis</name>
<affiliation>
<inist:fA14 i1="01">
<s1>John A. Moran Eye Center, University of Utah</s1>
<s2>Salt Lake City, Utah</s2>
<s3>USA</s3>
<sZ>1 aut.</sZ>
</inist:fA14>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">INIST</idno>
<idno type="inist">00-0125695</idno>
<date when="2000">2000</date>
<idno type="stanalyst">PASCAL 00-0125695 INIST</idno>
<idno type="RBID">Pascal:00-0125695</idno>
<idno type="wicri:Area/PascalFrancis/Corpus">001496</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a">Incision width after phacoemulsification with foldable intraocular lens implantation</title>
<author>
<name sortKey="Mamalis, N" sort="Mamalis, N" uniqKey="Mamalis N" first="N." last="Mamalis">N. Mamalis</name>
<affiliation>
<inist:fA14 i1="01">
<s1>John A. Moran Eye Center, University of Utah</s1>
<s2>Salt Lake City, Utah</s2>
<s3>USA</s3>
<sZ>1 aut.</sZ>
</inist:fA14>
</affiliation>
</author>
</analytic>
<series>
<title level="j" type="main">Journal of cataract and refractive surgery</title>
<title level="j" type="abbreviated">J. cataract refractive surg.</title>
<idno type="ISSN">0886-3350</idno>
<imprint>
<date when="2000">2000</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt>
<title level="j" type="main">Journal of cataract and refractive surgery</title>
<title level="j" type="abbreviated">J. cataract refractive surg.</title>
<idno type="ISSN">0886-3350</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Eye</term>
<term>Human</term>
<term>Implantation</term>
<term>Intraocular lens</term>
<term>Lens</term>
<term>Phacoemulsification</term>
<term>Size</term>
<term>Surgical incision</term>
</keywords>
<keywords scheme="Pascal" xml:lang="fr">
<term>Phacoémulsification</term>
<term>Cristallin</term>
<term>Oeil</term>
<term>Lentille intraoculaire</term>
<term>Implantation</term>
<term>Incision chirurgicale</term>
<term>Taille</term>
<term>Homme</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Purpose: To determine the incision size after insertion of foldable intraocular lenses (lOLs) using both a forceps and injectors. Setting: Intermountain Ocular Research Center, Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. Methods: One hundred patients had phacoemulsification through a clear corneal wound. The incision width was measured before and after IOL implantation. A 3-piece silicone IOL and a 3-piece acrylic IOL (both with an optic diameter of 5.5 mm) were inserted using a forceps. A plate-haptic silicone lens and a 3-piece silicone lens with a 6.0 mm diameter optic were inserted using an injector. Results: The wound size in the group with the 3-piece silicone lens inserted with a forceps enlarged 4.4% (3.23 to 3.38 mm) in the low-power IOL group (15.0 to 20.0 diopters [D]) and 6.2% (3.24 to 3.44 mm) in the high-power IOL group (20.5 to 25.0 D). Similarly, the acrylic IOL wound enlarged 5% (3.21 to 3.37 mm) in the low-power IOL group and 6% (3.25 to 3.44 mm) in the high-power IOL group when a forceps was used. The 3-piece silicone and plate silicone lenses inserted using an injector enlarged the wound 3.2% and 3.3% (3.02 to 3.11 mm and 3.05 to 3.15 mm), respectively. There was no difference in the wound size with higher IOL powers in eyes with injected lenses. Conclusions: Clear corneal incisions enlarge after insertion of foldable lOLs in a predictable manner, with a forceps-inserted IOL enlarging the wound diameter more than lenses inserted with an injector. The forceps-inserted lens group also showed a difference in wound size related to IOL power.</div>
</front>
</TEI>
<inist>
<standard h6="B">
<pA>
<fA01 i1="01" i2="1">
<s0>0886-3350</s0>
</fA01>
<fA02 i1="01">
<s0>JCSUEV</s0>
</fA02>
<fA03 i2="1">
<s0>J. cataract refractive surg.</s0>
</fA03>
<fA05>
<s2>26</s2>
</fA05>
<fA06>
<s2>2</s2>
</fA06>
<fA08 i1="01" i2="1" l="ENG">
<s1>Incision width after phacoemulsification with foldable intraocular lens implantation</s1>
</fA08>
<fA11 i1="01" i2="1">
<s1>MAMALIS (N.)</s1>
</fA11>
<fA14 i1="01">
<s1>John A. Moran Eye Center, University of Utah</s1>
<s2>Salt Lake City, Utah</s2>
<s3>USA</s3>
<sZ>1 aut.</sZ>
</fA14>
<fA20>
<s1>237-241</s1>
</fA20>
<fA21>
<s1>2000</s1>
</fA21>
<fA23 i1="01">
<s0>ENG</s0>
</fA23>
<fA43 i1="01">
<s1>INIST</s1>
<s2>20937</s2>
<s5>354000081903090100</s5>
</fA43>
<fA44>
<s0>0000</s0>
<s1>© 2000 INIST-CNRS. All rights reserved.</s1>
</fA44>
<fA45>
<s0>13 ref.</s0>
</fA45>
<fA47 i1="01" i2="1">
<s0>00-0125695</s0>
</fA47>
<fA60>
<s1>P</s1>
</fA60>
<fA61>
<s0>A</s0>
</fA61>
<fA64 i1="01" i2="1">
<s0>Journal of cataract and refractive surgery</s0>
</fA64>
<fA66 i1="01">
<s0>USA</s0>
</fA66>
<fC01 i1="01" l="ENG">
<s0>Purpose: To determine the incision size after insertion of foldable intraocular lenses (lOLs) using both a forceps and injectors. Setting: Intermountain Ocular Research Center, Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. Methods: One hundred patients had phacoemulsification through a clear corneal wound. The incision width was measured before and after IOL implantation. A 3-piece silicone IOL and a 3-piece acrylic IOL (both with an optic diameter of 5.5 mm) were inserted using a forceps. A plate-haptic silicone lens and a 3-piece silicone lens with a 6.0 mm diameter optic were inserted using an injector. Results: The wound size in the group with the 3-piece silicone lens inserted with a forceps enlarged 4.4% (3.23 to 3.38 mm) in the low-power IOL group (15.0 to 20.0 diopters [D]) and 6.2% (3.24 to 3.44 mm) in the high-power IOL group (20.5 to 25.0 D). Similarly, the acrylic IOL wound enlarged 5% (3.21 to 3.37 mm) in the low-power IOL group and 6% (3.25 to 3.44 mm) in the high-power IOL group when a forceps was used. The 3-piece silicone and plate silicone lenses inserted using an injector enlarged the wound 3.2% and 3.3% (3.02 to 3.11 mm and 3.05 to 3.15 mm), respectively. There was no difference in the wound size with higher IOL powers in eyes with injected lenses. Conclusions: Clear corneal incisions enlarge after insertion of foldable lOLs in a predictable manner, with a forceps-inserted IOL enlarging the wound diameter more than lenses inserted with an injector. The forceps-inserted lens group also showed a difference in wound size related to IOL power.</s0>
</fC01>
<fC02 i1="01" i2="X">
<s0>002B25B</s0>
</fC02>
<fC03 i1="01" i2="X" l="FRE">
<s0>Phacoémulsification</s0>
<s5>01</s5>
</fC03>
<fC03 i1="01" i2="X" l="ENG">
<s0>Phacoemulsification</s0>
<s5>01</s5>
</fC03>
<fC03 i1="01" i2="X" l="SPA">
<s0>Facoemulsificación</s0>
<s5>01</s5>
</fC03>
<fC03 i1="02" i2="X" l="FRE">
<s0>Cristallin</s0>
<s5>02</s5>
</fC03>
<fC03 i1="02" i2="X" l="ENG">
<s0>Lens</s0>
<s5>02</s5>
</fC03>
<fC03 i1="02" i2="X" l="SPA">
<s0>Cristalino</s0>
<s5>02</s5>
</fC03>
<fC03 i1="03" i2="X" l="FRE">
<s0>Oeil</s0>
<s5>03</s5>
</fC03>
<fC03 i1="03" i2="X" l="ENG">
<s0>Eye</s0>
<s5>03</s5>
</fC03>
<fC03 i1="03" i2="X" l="SPA">
<s0>Ojo</s0>
<s5>03</s5>
</fC03>
<fC03 i1="04" i2="X" l="FRE">
<s0>Lentille intraoculaire</s0>
<s5>04</s5>
</fC03>
<fC03 i1="04" i2="X" l="ENG">
<s0>Intraocular lens</s0>
<s5>04</s5>
</fC03>
<fC03 i1="04" i2="X" l="SPA">
<s0>Lente intraocular</s0>
<s5>04</s5>
</fC03>
<fC03 i1="05" i2="X" l="FRE">
<s0>Implantation</s0>
<s5>05</s5>
</fC03>
<fC03 i1="05" i2="X" l="ENG">
<s0>Implantation</s0>
<s5>05</s5>
</fC03>
<fC03 i1="05" i2="X" l="SPA">
<s0>Implantación</s0>
<s5>05</s5>
</fC03>
<fC03 i1="06" i2="X" l="FRE">
<s0>Incision chirurgicale</s0>
<s5>07</s5>
</fC03>
<fC03 i1="06" i2="X" l="ENG">
<s0>Surgical incision</s0>
<s5>07</s5>
</fC03>
<fC03 i1="06" i2="X" l="SPA">
<s0>Incisión quirúrgica</s0>
<s5>07</s5>
</fC03>
<fC03 i1="07" i2="X" l="FRE">
<s0>Taille</s0>
<s5>08</s5>
</fC03>
<fC03 i1="07" i2="X" l="ENG">
<s0>Size</s0>
<s5>08</s5>
</fC03>
<fC03 i1="07" i2="X" l="SPA">
<s0>Talla</s0>
<s5>08</s5>
</fC03>
<fC03 i1="08" i2="X" l="FRE">
<s0>Homme</s0>
<s5>10</s5>
</fC03>
<fC03 i1="08" i2="X" l="ENG">
<s0>Human</s0>
<s5>10</s5>
</fC03>
<fC03 i1="08" i2="X" l="SPA">
<s0>Hombre</s0>
<s5>10</s5>
</fC03>
<fC07 i1="01" i2="X" l="FRE">
<s0>Chirurgie</s0>
<s5>37</s5>
</fC07>
<fC07 i1="01" i2="X" l="ENG">
<s0>Surgery</s0>
<s5>37</s5>
</fC07>
<fC07 i1="01" i2="X" l="SPA">
<s0>Cirugía</s0>
<s5>37</s5>
</fC07>
<fN21>
<s1>094</s1>
</fN21>
</pA>
</standard>
<server>
<NO>PASCAL 00-0125695 INIST</NO>
<ET>Incision width after phacoemulsification with foldable intraocular lens implantation</ET>
<AU>MAMALIS (N.)</AU>
<AF>John A. Moran Eye Center, University of Utah/Salt Lake City, Utah/Etats-Unis (1 aut.)</AF>
<DT>Publication en série; Niveau analytique</DT>
<SO>Journal of cataract and refractive surgery; ISSN 0886-3350; Coden JCSUEV; Etats-Unis; Da. 2000; Vol. 26; No. 2; Pp. 237-241; Bibl. 13 ref.</SO>
<LA>Anglais</LA>
<EA>Purpose: To determine the incision size after insertion of foldable intraocular lenses (lOLs) using both a forceps and injectors. Setting: Intermountain Ocular Research Center, Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. Methods: One hundred patients had phacoemulsification through a clear corneal wound. The incision width was measured before and after IOL implantation. A 3-piece silicone IOL and a 3-piece acrylic IOL (both with an optic diameter of 5.5 mm) were inserted using a forceps. A plate-haptic silicone lens and a 3-piece silicone lens with a 6.0 mm diameter optic were inserted using an injector. Results: The wound size in the group with the 3-piece silicone lens inserted with a forceps enlarged 4.4% (3.23 to 3.38 mm) in the low-power IOL group (15.0 to 20.0 diopters [D]) and 6.2% (3.24 to 3.44 mm) in the high-power IOL group (20.5 to 25.0 D). Similarly, the acrylic IOL wound enlarged 5% (3.21 to 3.37 mm) in the low-power IOL group and 6% (3.25 to 3.44 mm) in the high-power IOL group when a forceps was used. The 3-piece silicone and plate silicone lenses inserted using an injector enlarged the wound 3.2% and 3.3% (3.02 to 3.11 mm and 3.05 to 3.15 mm), respectively. There was no difference in the wound size with higher IOL powers in eyes with injected lenses. Conclusions: Clear corneal incisions enlarge after insertion of foldable lOLs in a predictable manner, with a forceps-inserted IOL enlarging the wound diameter more than lenses inserted with an injector. The forceps-inserted lens group also showed a difference in wound size related to IOL power.</EA>
<CC>002B25B</CC>
<FD>Phacoémulsification; Cristallin; Oeil; Lentille intraoculaire; Implantation; Incision chirurgicale; Taille; Homme</FD>
<FG>Chirurgie</FG>
<ED>Phacoemulsification; Lens; Eye; Intraocular lens; Implantation; Surgical incision; Size; Human</ED>
<EG>Surgery</EG>
<SD>Facoemulsificación; Cristalino; Ojo; Lente intraocular; Implantación; Incisión quirúrgica; Talla; Hombre</SD>
<LO>INIST-20937.354000081903090100</LO>
<ID>00-0125695</ID>
</server>
</inist>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PascalFrancis/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001496 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PascalFrancis/Corpus/biblio.hfd -nk 001496 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    PascalFrancis
   |étape=   Corpus
   |type=    RBID
   |clé=     Pascal:00-0125695
   |texte=   Incision width after phacoemulsification with foldable intraocular lens implantation
}}

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024