Abstract
We describe a double-loop-knot technique for repositioning a displaced posterior chamber intraocular lens (IOL) that facilitates placement of scleral fixation sutures around the haptic for IOL stabilization. The technique minimizes the intraocular manipulations necessary to create a suture loop around the haptic of a dislocated IOL as well as scleral incisions required for IOL exchange.
Notice en format standard (ISO 2709)
Pour connaître la documentation sur le format Inist Standard.
pA |
|
---|
Format Inist (serveur)
NO : | PASCAL 04-0400749 INIST |
---|---|
ET : | Transscleral suture technique for fixation of a dislocated posterior chamber intraocular lens |
AU : | HAN (Quan-Hong); LIN WANG; HUI (Yan-Nian) |
AF : | Department of Ophthalmology, Xijing Hospital, The Fourth Military Medical University/Xi'an, Shaanxi/Chine (1 aut., 2 aut., 3 aut.) |
DT : | Publication en série; Niveau analytique |
SO : | Journal of cataract and refractive surgery; ISSN 0886-3350; Coden JCSUEV; Etats-Unis; Da. 2004; Vol. 30; No. 7; Pp. 1396-1400; Bibl. 24 ref. |
LA : | Anglais |
EA : | We describe a double-loop-knot technique for repositioning a displaced posterior chamber intraocular lens (IOL) that facilitates placement of scleral fixation sutures around the haptic for IOL stabilization. The technique minimizes the intraocular manipulations necessary to create a suture loop around the haptic of a dislocated IOL as well as scleral incisions required for IOL exchange. |
CC : | 002B25B |
FD : | Sclérotique; Suture chirurgicale; Technique; Fixation; Lentille intraoculaire; Intraoculaire; Chirurgie; Ophtalmologie; Traitement |
ED : | Sclera; Suturation; Technique; Fixation; Intraocular lens; Intraocular; Surgery; Ophthalmology; Treatment |
SD : | Esclerótica; Sutura quirúrgica; Técnica; Fijación; Lente intraocular; Intraocular; Cirugía; Oftalmología; Tratamiento |
LO : | INIST-20937.354000112151500010 |
ID : | 04-0400749 |
Links to Exploration step
Pascal:04-0400749Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en" level="a">Transscleral suture technique for fixation of a dislocated posterior chamber intraocular lens</title>
<author><name sortKey="Han, Quan Hong" sort="Han, Quan Hong" uniqKey="Han Q" first="Quan-Hong" last="Han">Quan-Hong Han</name>
<affiliation><inist:fA14 i1="01"><s1>Department of Ophthalmology, Xijing Hospital, The Fourth Military Medical University</s1>
<s2>Xi'an, Shaanxi</s2>
<s3>CHN</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
<sZ>3 aut.</sZ>
</inist:fA14>
</affiliation>
</author>
<author><name sortKey="Lin Wang" sort="Lin Wang" uniqKey="Lin Wang" last="Lin Wang">LIN WANG</name>
<affiliation><inist:fA14 i1="01"><s1>Department of Ophthalmology, Xijing Hospital, The Fourth Military Medical University</s1>
<s2>Xi'an, Shaanxi</s2>
<s3>CHN</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
<sZ>3 aut.</sZ>
</inist:fA14>
</affiliation>
</author>
<author><name sortKey="Hui, Yan Nian" sort="Hui, Yan Nian" uniqKey="Hui Y" first="Yan-Nian" last="Hui">Yan-Nian Hui</name>
<affiliation><inist:fA14 i1="01"><s1>Department of Ophthalmology, Xijing Hospital, The Fourth Military Medical University</s1>
<s2>Xi'an, Shaanxi</s2>
<s3>CHN</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
<sZ>3 aut.</sZ>
</inist:fA14>
</affiliation>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">INIST</idno>
<idno type="inist">04-0400749</idno>
<date when="2004">2004</date>
<idno type="stanalyst">PASCAL 04-0400749 INIST</idno>
<idno type="RBID">Pascal:04-0400749</idno>
<idno type="wicri:Area/PascalFrancis/Corpus">000F66</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en" level="a">Transscleral suture technique for fixation of a dislocated posterior chamber intraocular lens</title>
<author><name sortKey="Han, Quan Hong" sort="Han, Quan Hong" uniqKey="Han Q" first="Quan-Hong" last="Han">Quan-Hong Han</name>
<affiliation><inist:fA14 i1="01"><s1>Department of Ophthalmology, Xijing Hospital, The Fourth Military Medical University</s1>
<s2>Xi'an, Shaanxi</s2>
<s3>CHN</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
<sZ>3 aut.</sZ>
</inist:fA14>
</affiliation>
</author>
<author><name sortKey="Lin Wang" sort="Lin Wang" uniqKey="Lin Wang" last="Lin Wang">LIN WANG</name>
<affiliation><inist:fA14 i1="01"><s1>Department of Ophthalmology, Xijing Hospital, The Fourth Military Medical University</s1>
<s2>Xi'an, Shaanxi</s2>
<s3>CHN</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
<sZ>3 aut.</sZ>
</inist:fA14>
</affiliation>
</author>
<author><name sortKey="Hui, Yan Nian" sort="Hui, Yan Nian" uniqKey="Hui Y" first="Yan-Nian" last="Hui">Yan-Nian Hui</name>
<affiliation><inist:fA14 i1="01"><s1>Department of Ophthalmology, Xijing Hospital, The Fourth Military Medical University</s1>
<s2>Xi'an, Shaanxi</s2>
<s3>CHN</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
<sZ>3 aut.</sZ>
</inist:fA14>
</affiliation>
</author>
</analytic>
<series><title level="j" type="main">Journal of cataract and refractive surgery</title>
<title level="j" type="abbreviated">J. cataract refractive surg.</title>
<idno type="ISSN">0886-3350</idno>
<imprint><date when="2004">2004</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt><title level="j" type="main">Journal of cataract and refractive surgery</title>
<title level="j" type="abbreviated">J. cataract refractive surg.</title>
<idno type="ISSN">0886-3350</idno>
</seriesStmt>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Fixation</term>
<term>Intraocular</term>
<term>Intraocular lens</term>
<term>Ophthalmology</term>
<term>Sclera</term>
<term>Surgery</term>
<term>Suturation</term>
<term>Technique</term>
<term>Treatment</term>
</keywords>
<keywords scheme="Pascal" xml:lang="fr"><term>Sclérotique</term>
<term>Suture chirurgicale</term>
<term>Technique</term>
<term>Fixation</term>
<term>Lentille intraoculaire</term>
<term>Intraoculaire</term>
<term>Chirurgie</term>
<term>Ophtalmologie</term>
<term>Traitement</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">We describe a double-loop-knot technique for repositioning a displaced posterior chamber intraocular lens (IOL) that facilitates placement of scleral fixation sutures around the haptic for IOL stabilization. The technique minimizes the intraocular manipulations necessary to create a suture loop around the haptic of a dislocated IOL as well as scleral incisions required for IOL exchange.</div>
</front>
</TEI>
<inist><standard h6="B"><pA><fA01 i1="01" i2="1"><s0>0886-3350</s0>
</fA01>
<fA02 i1="01"><s0>JCSUEV</s0>
</fA02>
<fA03 i2="1"><s0>J. cataract refractive surg.</s0>
</fA03>
<fA05><s2>30</s2>
</fA05>
<fA06><s2>7</s2>
</fA06>
<fA08 i1="01" i2="1" l="ENG"><s1>Transscleral suture technique for fixation of a dislocated posterior chamber intraocular lens</s1>
</fA08>
<fA11 i1="01" i2="1"><s1>HAN (Quan-Hong)</s1>
</fA11>
<fA11 i1="02" i2="1"><s1>LIN WANG</s1>
</fA11>
<fA11 i1="03" i2="1"><s1>HUI (Yan-Nian)</s1>
</fA11>
<fA14 i1="01"><s1>Department of Ophthalmology, Xijing Hospital, The Fourth Military Medical University</s1>
<s2>Xi'an, Shaanxi</s2>
<s3>CHN</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
<sZ>3 aut.</sZ>
</fA14>
<fA20><s1>1396-1400</s1>
</fA20>
<fA21><s1>2004</s1>
</fA21>
<fA23 i1="01"><s0>ENG</s0>
</fA23>
<fA43 i1="01"><s1>INIST</s1>
<s2>20937</s2>
<s5>354000112151500010</s5>
</fA43>
<fA44><s0>0000</s0>
<s1>© 2004 INIST-CNRS. All rights reserved.</s1>
</fA44>
<fA45><s0>24 ref.</s0>
</fA45>
<fA47 i1="01" i2="1"><s0>04-0400749</s0>
</fA47>
<fA60><s1>P</s1>
</fA60>
<fA61><s0>A</s0>
</fA61>
<fA64 i1="01" i2="1"><s0>Journal of cataract and refractive surgery</s0>
</fA64>
<fA66 i1="01"><s0>USA</s0>
</fA66>
<fC01 i1="01" l="ENG"><s0>We describe a double-loop-knot technique for repositioning a displaced posterior chamber intraocular lens (IOL) that facilitates placement of scleral fixation sutures around the haptic for IOL stabilization. The technique minimizes the intraocular manipulations necessary to create a suture loop around the haptic of a dislocated IOL as well as scleral incisions required for IOL exchange.</s0>
</fC01>
<fC02 i1="01" i2="X"><s0>002B25B</s0>
</fC02>
<fC03 i1="01" i2="X" l="FRE"><s0>Sclérotique</s0>
<s5>02</s5>
</fC03>
<fC03 i1="01" i2="X" l="ENG"><s0>Sclera</s0>
<s5>02</s5>
</fC03>
<fC03 i1="01" i2="X" l="SPA"><s0>Esclerótica</s0>
<s5>02</s5>
</fC03>
<fC03 i1="02" i2="X" l="FRE"><s0>Suture chirurgicale</s0>
<s5>03</s5>
</fC03>
<fC03 i1="02" i2="X" l="ENG"><s0>Suturation</s0>
<s5>03</s5>
</fC03>
<fC03 i1="02" i2="X" l="SPA"><s0>Sutura quirúrgica</s0>
<s5>03</s5>
</fC03>
<fC03 i1="03" i2="X" l="FRE"><s0>Technique</s0>
<s5>05</s5>
</fC03>
<fC03 i1="03" i2="X" l="ENG"><s0>Technique</s0>
<s5>05</s5>
</fC03>
<fC03 i1="03" i2="X" l="SPA"><s0>Técnica</s0>
<s5>05</s5>
</fC03>
<fC03 i1="04" i2="X" l="FRE"><s0>Fixation</s0>
<s5>06</s5>
</fC03>
<fC03 i1="04" i2="X" l="ENG"><s0>Fixation</s0>
<s5>06</s5>
</fC03>
<fC03 i1="04" i2="X" l="SPA"><s0>Fijación</s0>
<s5>06</s5>
</fC03>
<fC03 i1="05" i2="X" l="FRE"><s0>Lentille intraoculaire</s0>
<s5>08</s5>
</fC03>
<fC03 i1="05" i2="X" l="ENG"><s0>Intraocular lens</s0>
<s5>08</s5>
</fC03>
<fC03 i1="05" i2="X" l="SPA"><s0>Lente intraocular</s0>
<s5>08</s5>
</fC03>
<fC03 i1="06" i2="X" l="FRE"><s0>Intraoculaire</s0>
<s5>09</s5>
</fC03>
<fC03 i1="06" i2="X" l="ENG"><s0>Intraocular</s0>
<s5>09</s5>
</fC03>
<fC03 i1="06" i2="X" l="SPA"><s0>Intraocular</s0>
<s5>09</s5>
</fC03>
<fC03 i1="07" i2="X" l="FRE"><s0>Chirurgie</s0>
<s5>11</s5>
</fC03>
<fC03 i1="07" i2="X" l="ENG"><s0>Surgery</s0>
<s5>11</s5>
</fC03>
<fC03 i1="07" i2="X" l="SPA"><s0>Cirugía</s0>
<s5>11</s5>
</fC03>
<fC03 i1="08" i2="X" l="FRE"><s0>Ophtalmologie</s0>
<s5>12</s5>
</fC03>
<fC03 i1="08" i2="X" l="ENG"><s0>Ophthalmology</s0>
<s5>12</s5>
</fC03>
<fC03 i1="08" i2="X" l="SPA"><s0>Oftalmología</s0>
<s5>12</s5>
</fC03>
<fC03 i1="09" i2="X" l="FRE"><s0>Traitement</s0>
<s5>25</s5>
</fC03>
<fC03 i1="09" i2="X" l="ENG"><s0>Treatment</s0>
<s5>25</s5>
</fC03>
<fC03 i1="09" i2="X" l="SPA"><s0>Tratamiento</s0>
<s5>25</s5>
</fC03>
<fN21><s1>229</s1>
</fN21>
<fN44 i1="01"><s1>OTO</s1>
</fN44>
<fN82><s1>OTO</s1>
</fN82>
</pA>
</standard>
<server><NO>PASCAL 04-0400749 INIST</NO>
<ET>Transscleral suture technique for fixation of a dislocated posterior chamber intraocular lens</ET>
<AU>HAN (Quan-Hong); LIN WANG; HUI (Yan-Nian)</AU>
<AF>Department of Ophthalmology, Xijing Hospital, The Fourth Military Medical University/Xi'an, Shaanxi/Chine (1 aut., 2 aut., 3 aut.)</AF>
<DT>Publication en série; Niveau analytique</DT>
<SO>Journal of cataract and refractive surgery; ISSN 0886-3350; Coden JCSUEV; Etats-Unis; Da. 2004; Vol. 30; No. 7; Pp. 1396-1400; Bibl. 24 ref.</SO>
<LA>Anglais</LA>
<EA>We describe a double-loop-knot technique for repositioning a displaced posterior chamber intraocular lens (IOL) that facilitates placement of scleral fixation sutures around the haptic for IOL stabilization. The technique minimizes the intraocular manipulations necessary to create a suture loop around the haptic of a dislocated IOL as well as scleral incisions required for IOL exchange.</EA>
<CC>002B25B</CC>
<FD>Sclérotique; Suture chirurgicale; Technique; Fixation; Lentille intraoculaire; Intraoculaire; Chirurgie; Ophtalmologie; Traitement</FD>
<ED>Sclera; Suturation; Technique; Fixation; Intraocular lens; Intraocular; Surgery; Ophthalmology; Treatment</ED>
<SD>Esclerótica; Sutura quirúrgica; Técnica; Fijación; Lente intraocular; Intraocular; Cirugía; Oftalmología; Tratamiento</SD>
<LO>INIST-20937.354000112151500010</LO>
<ID>04-0400749</ID>
</server>
</inist>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PascalFrancis/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000F66 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/PascalFrancis/Corpus/biblio.hfd -nk 000F66 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Ticri/CIDE |area= HapticV1 |flux= PascalFrancis |étape= Corpus |type= RBID |clé= Pascal:04-0400749 |texte= Transscleral suture technique for fixation of a dislocated posterior chamber intraocular lens }}
![]() | This area was generated with Dilib version V0.6.23. | ![]() |