THz and mm-Wave Sensing of Corneal Tissue Water Content: In Vivo Sensing and Imaging Results

Identifieur interne : 003A78 ( Ncbi/Curation ); précédent : 003A77; suivant : 003A79

THz and mm-Wave Sensing of Corneal Tissue Water Content: In Vivo Sensing and Imaging Results

Auteurs : Zachary D. Taylor ; James Garritano ; Shijun Sung ; Neha Bajwa ; David B. Bennett ; Bryan Nowroozi ; Priyamvada Tewari ; James W. Sayre ; Jean-Pierre Hubschman ; Sophie X. Deng ; Elliott R. Brown ; Warren S. Grundfest

Source :

RBID : PMC:4493917

Abstract

A pulsed terahertz (THz) imaging system and millimeter-wave reflectometer were used to acquire images and point measurements, respectively, of five rabbit cornea in vivo. These imaging results are the first ever produced of in vivo cornea. A modified version of a standard protocol using a gentle stream of air and a Mylar window was employed to slightly dehydrate healthy cornea. The sensor data and companion central corneal thickness (CCT) measurements were acquired every 10–15 min over the course of two hours using ultrasound pachymmetry.. Statistically significant positive correlations were established between CCT measurements and millimeter wave reflectivity. Local shifts in reflectivity contrast were observed in the THz imagery; however, the THz reflectivity did not display a significant correlation with thickness in the region probed by the 100 GHz and CCT measurements. This is explained in part by a thickness sensitivity at least 10× higher in the mm-wave than the THz systems. Stratified media and effective media modeling suggest that the protocol perturbed the thickness and not the corneal tissue water content (CTWC). To further explore possible etalon effects, an additional rabbit was euthanized and millimeter wave measurements were obtained during death induced edema. These observations represent the first time that the uncoupled sensing of CTWC and CCT have been achieved in vivo.


Url:
DOI: 10.1109/TTHZ.2015.2392628
PubMed: 26161292
PubMed Central: 4493917

Links toward previous steps (curation, corpus...)


Links to Exploration step

PMC:4493917

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">THz and mm-Wave Sensing of Corneal Tissue Water Content:
<italic>In Vivo</italic>
Sensing and Imaging Results</title>
<author>
<name sortKey="Taylor, Zachary D" sort="Taylor, Zachary D" uniqKey="Taylor Z" first="Zachary D." last="Taylor">Zachary D. Taylor</name>
</author>
<author>
<name sortKey="Garritano, James" sort="Garritano, James" uniqKey="Garritano J" first="James" last="Garritano">James Garritano</name>
</author>
<author>
<name sortKey="Sung, Shijun" sort="Sung, Shijun" uniqKey="Sung S" first="Shijun" last="Sung">Shijun Sung</name>
</author>
<author>
<name sortKey="Bajwa, Neha" sort="Bajwa, Neha" uniqKey="Bajwa N" first="Neha" last="Bajwa">Neha Bajwa</name>
</author>
<author>
<name sortKey="Bennett, David B" sort="Bennett, David B" uniqKey="Bennett D" first="David B." last="Bennett">David B. Bennett</name>
</author>
<author>
<name sortKey="Nowroozi, Bryan" sort="Nowroozi, Bryan" uniqKey="Nowroozi B" first="Bryan" last="Nowroozi">Bryan Nowroozi</name>
</author>
<author>
<name sortKey="Tewari, Priyamvada" sort="Tewari, Priyamvada" uniqKey="Tewari P" first="Priyamvada" last="Tewari">Priyamvada Tewari</name>
</author>
<author>
<name sortKey="Sayre, James W" sort="Sayre, James W" uniqKey="Sayre J" first="James W." last="Sayre">James W. Sayre</name>
</author>
<author>
<name sortKey="Hubschman, Jean Pierre" sort="Hubschman, Jean Pierre" uniqKey="Hubschman J" first="Jean-Pierre" last="Hubschman">Jean-Pierre Hubschman</name>
</author>
<author>
<name sortKey="Deng, Sophie X" sort="Deng, Sophie X" uniqKey="Deng S" first="Sophie X." last="Deng">Sophie X. Deng</name>
</author>
<author>
<name sortKey="Brown, Elliott R" sort="Brown, Elliott R" uniqKey="Brown E" first="Elliott R." last="Brown">Elliott R. Brown</name>
</author>
<author>
<name sortKey="Grundfest, Warren S" sort="Grundfest, Warren S" uniqKey="Grundfest W" first="Warren S." last="Grundfest">Warren S. Grundfest</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PMC</idno>
<idno type="pmid">26161292</idno>
<idno type="pmc">4493917</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4493917</idno>
<idno type="RBID">PMC:4493917</idno>
<idno type="doi">10.1109/TTHZ.2015.2392628</idno>
<date when="2015">2015</date>
<idno type="wicri:Area/Pmc/Corpus">001871</idno>
<idno type="wicri:Area/Pmc/Curation">001871</idno>
<idno type="wicri:Area/Pmc/Checkpoint">000302</idno>
<idno type="wicri:Area/Ncbi/Merge">003A78</idno>
<idno type="wicri:Area/Ncbi/Curation">003A78</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a" type="main">THz and mm-Wave Sensing of Corneal Tissue Water Content:
<italic>In Vivo</italic>
Sensing and Imaging Results</title>
<author>
<name sortKey="Taylor, Zachary D" sort="Taylor, Zachary D" uniqKey="Taylor Z" first="Zachary D." last="Taylor">Zachary D. Taylor</name>
</author>
<author>
<name sortKey="Garritano, James" sort="Garritano, James" uniqKey="Garritano J" first="James" last="Garritano">James Garritano</name>
</author>
<author>
<name sortKey="Sung, Shijun" sort="Sung, Shijun" uniqKey="Sung S" first="Shijun" last="Sung">Shijun Sung</name>
</author>
<author>
<name sortKey="Bajwa, Neha" sort="Bajwa, Neha" uniqKey="Bajwa N" first="Neha" last="Bajwa">Neha Bajwa</name>
</author>
<author>
<name sortKey="Bennett, David B" sort="Bennett, David B" uniqKey="Bennett D" first="David B." last="Bennett">David B. Bennett</name>
</author>
<author>
<name sortKey="Nowroozi, Bryan" sort="Nowroozi, Bryan" uniqKey="Nowroozi B" first="Bryan" last="Nowroozi">Bryan Nowroozi</name>
</author>
<author>
<name sortKey="Tewari, Priyamvada" sort="Tewari, Priyamvada" uniqKey="Tewari P" first="Priyamvada" last="Tewari">Priyamvada Tewari</name>
</author>
<author>
<name sortKey="Sayre, James W" sort="Sayre, James W" uniqKey="Sayre J" first="James W." last="Sayre">James W. Sayre</name>
</author>
<author>
<name sortKey="Hubschman, Jean Pierre" sort="Hubschman, Jean Pierre" uniqKey="Hubschman J" first="Jean-Pierre" last="Hubschman">Jean-Pierre Hubschman</name>
</author>
<author>
<name sortKey="Deng, Sophie X" sort="Deng, Sophie X" uniqKey="Deng S" first="Sophie X." last="Deng">Sophie X. Deng</name>
</author>
<author>
<name sortKey="Brown, Elliott R" sort="Brown, Elliott R" uniqKey="Brown E" first="Elliott R." last="Brown">Elliott R. Brown</name>
</author>
<author>
<name sortKey="Grundfest, Warren S" sort="Grundfest, Warren S" uniqKey="Grundfest W" first="Warren S." last="Grundfest">Warren S. Grundfest</name>
</author>
</analytic>
<series>
<title level="j">IEEE transactions on terahertz science and technology</title>
<idno type="ISSN">2156-342X</idno>
<idno type="eISSN">2156-3446</idno>
<imprint>
<date when="2015">2015</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">
<p id="P1">A pulsed terahertz (THz) imaging system and millimeter-wave reflectometer were used to acquire images and point measurements, respectively, of five rabbit cornea
<italic>in vivo</italic>
. These imaging results are the first ever produced of
<italic>in vivo</italic>
cornea. A modified version of a standard protocol using a gentle stream of air and a Mylar window was employed to slightly dehydrate healthy cornea. The sensor data and companion central corneal thickness (CCT) measurements were acquired every 10–15 min over the course of two hours using ultrasound pachymmetry.. Statistically significant positive correlations were established between CCT measurements and millimeter wave reflectivity. Local shifts in reflectivity contrast were observed in the THz imagery; however, the THz reflectivity did not display a significant correlation with thickness in the region probed by the 100 GHz and CCT measurements. This is explained in part by a thickness sensitivity at least 10× higher in the mm-wave than the THz systems. Stratified media and effective media modeling suggest that the protocol perturbed the thickness and not the corneal tissue water content (CTWC). To further explore possible etalon effects, an additional rabbit was euthanized and millimeter wave measurements were obtained during death induced edema. These observations represent the first time that the uncoupled sensing of CTWC and CCT have been achieved
<italic>in vivo</italic>
.</p>
</div>
</front>
</TEI>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Ncbi/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 003A78 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Ncbi/Curation/biblio.hfd -nk 003A78 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Ncbi
   |étape=   Curation
   |type=    RBID
   |clé=     PMC:4493917
   |texte=   THz and mm-Wave Sensing of Corneal Tissue Water Content: In Vivo Sensing and Imaging Results
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Ncbi/Curation/RBID.i   -Sk "pubmed:26161292" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Ncbi/Curation/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024