Forearm electromyographic changes with the use of a haptic force-feedback computer mouse
Identifieur interne : 006096 ( Main/Exploration ); précédent : 006095; suivant : 006097Forearm electromyographic changes with the use of a haptic force-feedback computer mouse
Auteurs : Jack T. Dennerlein [États-Unis] ; Maria-Helena J. Dimarino [États-Unis]Source :
- Human factors [ 0018-7208 ] ; 2006.
Descripteurs français
- Pascal (Inist)
- Wicri :
English descriptors
- KwdEn :
- Adult, Biomechanics, Computer hardware, Electromyography, Ergonomics, Feedback, Female, Forearm, Forearm (innervation), Human, Humans, Input output equipment, Male, Man machine relation, Manual task, Massachusetts, Motor control, Mouse (computer peripheral), Performance, Striated muscle, Touch, User interface, User-Computer Interface.
- MESH :
- geographic : Massachusetts.
- innervation : Forearm.
- Adult, Electromyography, Feedback, Female, Humans, Male, Touch, User-Computer Interface.
Abstract
Objective: To examine changes in biomechanical and motor control associated with a force-feedback computer mouse. Background: Haptic computer mice can improve the movement times for point-and-click tasks; however, changes in upper extremity biomechanics and motor control are unknown. Method: Eighteen people (ages 22-37 years) performed a point-and-click task 80 times using a force-feedback computer mouse across three different conditions: (a) no force feedback, emulating a conventional mouse; (b) a single attractive force field at the desired target that pulls the mouse to the center of the target; and (c) an attractive force field at the desired target as well as others between the two possible targets, distracting the user from the intended target. Cursor kinematics, wrist posture, and electromyographic (EMG) forearm muscle activity were recorded. Results: The point-and-click movements were 30% faster with the addition of a single force field and 3% faster with the addition of multiple force fields. The Fitts' law index of performance metrics improved from 2.9 bits/response to 4.1 bits/response for multiple attractive fields and to 6.0 bits/response for a single force field. For the distracting force fields, the cursor maximum velocities were over 50% faster. EMG amplitude values were largest for the distracting force fields. These data suggest that the operator uses increased muscle activity to accelerate the mouse through the distracting force fields. Conclusion: When implementing attractive haptic force fields, one needs to consider how to reduce these observed effects of potential distracting force fields. Application: Applications include human-computer interface design for pointing devices extensively used for the graphical user interface.
Affiliations:
Links toward previous steps (curation, corpus...)
- to stream PascalFrancis, to step Corpus: 000B86
- to stream PascalFrancis, to step Curation: 000909
- to stream PascalFrancis, to step Checkpoint: 000A01
- to stream Main, to step Merge: 006358
- to stream PubMed, to step Corpus: 001794
- to stream PubMed, to step Curation: 001794
- to stream PubMed, to step Checkpoint: 001601
- to stream Ncbi, to step Merge: 000928
- to stream Ncbi, to step Curation: 000928
- to stream Ncbi, to step Checkpoint: 000928
- to stream Main, to step Merge: 005E27
- to stream Main, to step Curation: 006096
Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en" level="a">Forearm electromyographic changes with the use of a haptic force-feedback computer mouse</title>
<author><name sortKey="Dennerlein, Jack T" sort="Dennerlein, Jack T" uniqKey="Dennerlein J" first="Jack T." last="Dennerlein">Jack T. Dennerlein</name>
<affiliation wicri:level="2"><inist:fA14 i1="01"><s1>Harvard School of Public Health</s1>
<s2>Boston, Massachusetts</s2>
<s3>USA</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
</inist:fA14>
<country>États-Unis</country>
<placeName><region type="state">Massachusetts</region>
</placeName>
</affiliation>
</author>
<author><name sortKey="Dimarino, Maria Helena J" sort="Dimarino, Maria Helena J" uniqKey="Dimarino M" first="Maria-Helena J." last="Dimarino">Maria-Helena J. Dimarino</name>
<affiliation wicri:level="2"><inist:fA14 i1="01"><s1>Harvard School of Public Health</s1>
<s2>Boston, Massachusetts</s2>
<s3>USA</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
</inist:fA14>
<country>États-Unis</country>
<placeName><region type="state">Massachusetts</region>
</placeName>
</affiliation>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">INIST</idno>
<idno type="inist">07-0115945</idno>
<date when="2006">2006</date>
<idno type="stanalyst">PASCAL 07-0115945 INIST</idno>
<idno type="RBID">Pascal:07-0115945</idno>
<idno type="wicri:Area/PascalFrancis/Corpus">000B86</idno>
<idno type="wicri:Area/PascalFrancis/Curation">000909</idno>
<idno type="wicri:Area/PascalFrancis/Checkpoint">000A01</idno>
<idno type="wicri:doubleKey">0018-7208:2006:Dennerlein J:forearm:electromyographic:changes</idno>
<idno type="wicri:Area/Main/Merge">006358</idno>
<idno type="wicri:source">PubMed</idno>
<idno type="RBID">pubmed:16696263</idno>
<idno type="wicri:Area/PubMed/Corpus">001794</idno>
<idno type="wicri:Area/PubMed/Curation">001794</idno>
<idno type="wicri:Area/PubMed/Checkpoint">001601</idno>
<idno type="wicri:Area/Ncbi/Merge">000928</idno>
<idno type="wicri:Area/Ncbi/Curation">000928</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">000928</idno>
<idno type="wicri:doubleKey">0018-7208:2006:Dennerlein J:forearm:electromyographic:changes</idno>
<idno type="wicri:Area/Main/Merge">005E27</idno>
<idno type="wicri:Area/Main/Curation">006096</idno>
<idno type="wicri:Area/Main/Exploration">006096</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en" level="a">Forearm electromyographic changes with the use of a haptic force-feedback computer mouse</title>
<author><name sortKey="Dennerlein, Jack T" sort="Dennerlein, Jack T" uniqKey="Dennerlein J" first="Jack T." last="Dennerlein">Jack T. Dennerlein</name>
<affiliation wicri:level="2"><inist:fA14 i1="01"><s1>Harvard School of Public Health</s1>
<s2>Boston, Massachusetts</s2>
<s3>USA</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
</inist:fA14>
<country>États-Unis</country>
<placeName><region type="state">Massachusetts</region>
</placeName>
</affiliation>
</author>
<author><name sortKey="Dimarino, Maria Helena J" sort="Dimarino, Maria Helena J" uniqKey="Dimarino M" first="Maria-Helena J." last="Dimarino">Maria-Helena J. Dimarino</name>
<affiliation wicri:level="2"><inist:fA14 i1="01"><s1>Harvard School of Public Health</s1>
<s2>Boston, Massachusetts</s2>
<s3>USA</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
</inist:fA14>
<country>États-Unis</country>
<placeName><region type="state">Massachusetts</region>
</placeName>
</affiliation>
</author>
</analytic>
<series><title level="j" type="main">Human factors</title>
<title level="j" type="abbreviated">Hum. factors</title>
<idno type="ISSN">0018-7208</idno>
<imprint><date when="2006">2006</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt><title level="j" type="main">Human factors</title>
<title level="j" type="abbreviated">Hum. factors</title>
<idno type="ISSN">0018-7208</idno>
</seriesStmt>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Adult</term>
<term>Biomechanics</term>
<term>Computer hardware</term>
<term>Electromyography</term>
<term>Ergonomics</term>
<term>Feedback</term>
<term>Female</term>
<term>Forearm</term>
<term>Forearm (innervation)</term>
<term>Human</term>
<term>Humans</term>
<term>Input output equipment</term>
<term>Male</term>
<term>Man machine relation</term>
<term>Manual task</term>
<term>Massachusetts</term>
<term>Motor control</term>
<term>Mouse (computer peripheral)</term>
<term>Performance</term>
<term>Striated muscle</term>
<term>Touch</term>
<term>User interface</term>
<term>User-Computer Interface</term>
</keywords>
<keywords scheme="MESH" type="geographic" xml:lang="en"><term>Massachusetts</term>
</keywords>
<keywords scheme="MESH" qualifier="innervation" xml:lang="en"><term>Forearm</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Adult</term>
<term>Electromyography</term>
<term>Feedback</term>
<term>Female</term>
<term>Humans</term>
<term>Male</term>
<term>Touch</term>
<term>User-Computer Interface</term>
</keywords>
<keywords scheme="Pascal" xml:lang="fr"><term>Homme</term>
<term>Ergonomie</term>
<term>Souris (ordinateur)</term>
<term>Equipement entrée sortie</term>
<term>Matériel informatique</term>
<term>Avant bras</term>
<term>Electromyographie</term>
<term>Biomécanique</term>
<term>Contrôle moteur</term>
<term>Boucle réaction</term>
<term>Interface utilisateur</term>
<term>Relation homme machine</term>
<term>Muscle strié</term>
<term>Performance</term>
<term>Tâche manuelle</term>
</keywords>
<keywords scheme="Wicri" type="topic" xml:lang="fr"><term>Homme</term>
<term>Ergonomie</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">Objective: To examine changes in biomechanical and motor control associated with a force-feedback computer mouse. Background: Haptic computer mice can improve the movement times for point-and-click tasks; however, changes in upper extremity biomechanics and motor control are unknown. Method: Eighteen people (ages 22-37 years) performed a point-and-click task 80 times using a force-feedback computer mouse across three different conditions: (a) no force feedback, emulating a conventional mouse; (b) a single attractive force field at the desired target that pulls the mouse to the center of the target; and (c) an attractive force field at the desired target as well as others between the two possible targets, distracting the user from the intended target. Cursor kinematics, wrist posture, and electromyographic (EMG) forearm muscle activity were recorded. Results: The point-and-click movements were 30% faster with the addition of a single force field and 3% faster with the addition of multiple force fields. The Fitts' law index of performance metrics improved from 2.9 bits/response to 4.1 bits/response for multiple attractive fields and to 6.0 bits/response for a single force field. For the distracting force fields, the cursor maximum velocities were over 50% faster. EMG amplitude values were largest for the distracting force fields. These data suggest that the operator uses increased muscle activity to accelerate the mouse through the distracting force fields. Conclusion: When implementing attractive haptic force fields, one needs to consider how to reduce these observed effects of potential distracting force fields. Application: Applications include human-computer interface design for pointing devices extensively used for the graphical user interface.</div>
</front>
</TEI>
<affiliations><list><country><li>États-Unis</li>
</country>
<region><li>Massachusetts</li>
</region>
</list>
<tree><country name="États-Unis"><region name="Massachusetts"><name sortKey="Dennerlein, Jack T" sort="Dennerlein, Jack T" uniqKey="Dennerlein J" first="Jack T." last="Dennerlein">Jack T. Dennerlein</name>
</region>
<name sortKey="Dimarino, Maria Helena J" sort="Dimarino, Maria Helena J" uniqKey="Dimarino M" first="Maria-Helena J." last="Dimarino">Maria-Helena J. Dimarino</name>
</country>
</tree>
</affiliations>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 006096 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 006096 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Ticri/CIDE |area= HapticV1 |flux= Main |étape= Exploration |type= RBID |clé= Pascal:07-0115945 |texte= Forearm electromyographic changes with the use of a haptic force-feedback computer mouse }}
This area was generated with Dilib version V0.6.23. |