Face-, expert, and referent validity of the Xitact LS500 Laparoscopy Simulator
Identifieur interne : 007391 ( Main/Exploration ); précédent : 007390; suivant : 007392Face-, expert, and referent validity of the Xitact LS500 Laparoscopy Simulator
Auteurs : M. Schijven [Pays-Bas] ; J. Jakimowicz [Pays-Bas]Source :
- Surgical endoscopy [ 0930-2794 ] ; 2002.
Descripteurs français
- Pascal (Inist)
- Wicri :
English descriptors
- KwdEn :
Abstract
Background: This study was undertaken to establish face-, expert, and referent validity of the Xitact LS500; a virtual reality laparoscopic cholecystectomy simulator. Methods: A four-page, 20-item structured questionnaire was presented to 120 surgeons attending a surgical convention. Participants received an instructed hands-on "tour" on the Xitact simulator. Data were analyzed according to the level of experience of the surgeon, resulting in an "expert group opinion" of 87 surgeons and a "referent group opinion" of 33 surgeons. Results: The majority of respondents believe Xitact has the potential to become a useful tool in teaching (93.1%) and measuring performance assessment (79.3%) in laparoscopic cholecystectomy. Expert- and referent-group opinion does not differ significantly on any of the presented statements. The opinion regarding the realism of the virtual laparoscopic cholecystectomy environment is favorable among both groups, although it is considered not yet perfect. The "haptic feedback" sensation of the Xitact is a parameter that needs further development. Conclusions: Both expert- and referent surgeons value Xitact to be an important and useful tool in the laparoscopic teaching setting. Further studies need to be performed to establish the construct validity of the simulator (e.g., to what extent is the simulator logically encompassed into a theoretical framework of acquiring skills, needed for the laparoscopic cholecystectomy) to measure shortening of learning curves on the laparoscopic cholecystectomy procedure, and ultimately to justify its use in the surgical curriculum.
Affiliations:
Links toward previous steps (curation, corpus...)
- to stream PascalFrancis, to step Corpus: 001204
- to stream PascalFrancis, to step Curation: 000307
- to stream PascalFrancis, to step Checkpoint: 001000
- to stream Main, to step Merge: 007940
- to stream Main, to step Curation: 007391
Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en" level="a">Face-, expert, and referent validity of the Xitact LS500 Laparoscopy Simulator</title>
<author><name sortKey="Schijven, M" sort="Schijven, M" uniqKey="Schijven M" first="M." last="Schijven">M. Schijven</name>
<affiliation wicri:level="1"><inist:fA14 i1="01"><s1>Department of Surgery, Catharina Hospital Eindhoven, Michelangelolaan 2, PO box 1350</s1>
<s2>5602 ZA Eindhoven</s2>
<s3>NLD</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
</inist:fA14>
<country>Pays-Bas</country>
<wicri:noRegion>5602 ZA Eindhoven</wicri:noRegion>
</affiliation>
</author>
<author><name sortKey="Jakimowicz, J" sort="Jakimowicz, J" uniqKey="Jakimowicz J" first="J." last="Jakimowicz">J. Jakimowicz</name>
<affiliation wicri:level="1"><inist:fA14 i1="01"><s1>Department of Surgery, Catharina Hospital Eindhoven, Michelangelolaan 2, PO box 1350</s1>
<s2>5602 ZA Eindhoven</s2>
<s3>NLD</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
</inist:fA14>
<country>Pays-Bas</country>
<wicri:noRegion>5602 ZA Eindhoven</wicri:noRegion>
</affiliation>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">INIST</idno>
<idno type="inist">03-0104962</idno>
<date when="2002">2002</date>
<idno type="stanalyst">PASCAL 03-0104962 INIST</idno>
<idno type="RBID">Pascal:03-0104962</idno>
<idno type="wicri:Area/PascalFrancis/Corpus">001204</idno>
<idno type="wicri:Area/PascalFrancis/Curation">000307</idno>
<idno type="wicri:Area/PascalFrancis/Checkpoint">001000</idno>
<idno type="wicri:doubleKey">0930-2794:2002:Schijven M:face:expert:and</idno>
<idno type="wicri:Area/Main/Merge">007940</idno>
<idno type="wicri:Area/Main/Curation">007391</idno>
<idno type="wicri:Area/Main/Exploration">007391</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en" level="a">Face-, expert, and referent validity of the Xitact LS500 Laparoscopy Simulator</title>
<author><name sortKey="Schijven, M" sort="Schijven, M" uniqKey="Schijven M" first="M." last="Schijven">M. Schijven</name>
<affiliation wicri:level="1"><inist:fA14 i1="01"><s1>Department of Surgery, Catharina Hospital Eindhoven, Michelangelolaan 2, PO box 1350</s1>
<s2>5602 ZA Eindhoven</s2>
<s3>NLD</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
</inist:fA14>
<country>Pays-Bas</country>
<wicri:noRegion>5602 ZA Eindhoven</wicri:noRegion>
</affiliation>
</author>
<author><name sortKey="Jakimowicz, J" sort="Jakimowicz, J" uniqKey="Jakimowicz J" first="J." last="Jakimowicz">J. Jakimowicz</name>
<affiliation wicri:level="1"><inist:fA14 i1="01"><s1>Department of Surgery, Catharina Hospital Eindhoven, Michelangelolaan 2, PO box 1350</s1>
<s2>5602 ZA Eindhoven</s2>
<s3>NLD</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
</inist:fA14>
<country>Pays-Bas</country>
<wicri:noRegion>5602 ZA Eindhoven</wicri:noRegion>
</affiliation>
</author>
</analytic>
<series><title level="j" type="main">Surgical endoscopy</title>
<title level="j" type="abbreviated">Surg. endosc.</title>
<idno type="ISSN">0930-2794</idno>
<imprint><date when="2002">2002</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt><title level="j" type="main">Surgical endoscopy</title>
<title level="j" type="abbreviated">Surg. endosc.</title>
<idno type="ISSN">0930-2794</idno>
</seriesStmt>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Computer simulation</term>
<term>Expertise</term>
<term>Laparoscopy</term>
<term>Objective analysis</term>
<term>Occupational education</term>
<term>Occupational training</term>
<term>Performance evaluation</term>
<term>Quality assurance</term>
<term>Surgeon</term>
<term>Virtual reality</term>
</keywords>
<keywords scheme="Pascal" xml:lang="fr"><term>Formation professionnelle</term>
<term>Enseignement professionnel</term>
<term>Chirurgien</term>
<term>Laparoscopie</term>
<term>Evaluation performance</term>
<term>Simulation ordinateur</term>
<term>Réalité virtuelle</term>
<term>Assurance qualité</term>
<term>Expertise</term>
<term>Analyse objective</term>
</keywords>
<keywords scheme="Wicri" type="topic" xml:lang="fr"><term>Formation professionnelle</term>
<term>Enseignement professionnel</term>
<term>Chirurgien</term>
<term>Réalité virtuelle</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">Background: This study was undertaken to establish face-, expert, and referent validity of the Xitact LS500; a virtual reality laparoscopic cholecystectomy simulator. Methods: A four-page, 20-item structured questionnaire was presented to 120 surgeons attending a surgical convention. Participants received an instructed hands-on "tour" on the Xitact simulator. Data were analyzed according to the level of experience of the surgeon, resulting in an "expert group opinion" of 87 surgeons and a "referent group opinion" of 33 surgeons. Results: The majority of respondents believe Xitact has the potential to become a useful tool in teaching (93.1%) and measuring performance assessment (79.3%) in laparoscopic cholecystectomy. Expert- and referent-group opinion does not differ significantly on any of the presented statements. The opinion regarding the realism of the virtual laparoscopic cholecystectomy environment is favorable among both groups, although it is considered not yet perfect. The "haptic feedback" sensation of the Xitact is a parameter that needs further development. Conclusions: Both expert- and referent surgeons value Xitact to be an important and useful tool in the laparoscopic teaching setting. Further studies need to be performed to establish the construct validity of the simulator (e.g., to what extent is the simulator logically encompassed into a theoretical framework of acquiring skills, needed for the laparoscopic cholecystectomy) to measure shortening of learning curves on the laparoscopic cholecystectomy procedure, and ultimately to justify its use in the surgical curriculum.</div>
</front>
</TEI>
<affiliations><list><country><li>Pays-Bas</li>
</country>
</list>
<tree><country name="Pays-Bas"><noRegion><name sortKey="Schijven, M" sort="Schijven, M" uniqKey="Schijven M" first="M." last="Schijven">M. Schijven</name>
</noRegion>
<name sortKey="Jakimowicz, J" sort="Jakimowicz, J" uniqKey="Jakimowicz J" first="J." last="Jakimowicz">J. Jakimowicz</name>
</country>
</tree>
</affiliations>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 007391 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 007391 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Ticri/CIDE |area= HapticV1 |flux= Main |étape= Exploration |type= RBID |clé= Pascal:03-0104962 |texte= Face-, expert, and referent validity of the Xitact LS500 Laparoscopy Simulator }}
![]() | This area was generated with Dilib version V0.6.23. | ![]() |