Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

The FeTouch project: an application of haptic technologies to obstetrics and gynaecology.

Identifieur interne : 001631 ( PubMed/Corpus ); précédent : 001630; suivant : 001632

The FeTouch project: an application of haptic technologies to obstetrics and gynaecology.

Auteurs : D. Prattichizzo ; B. La Torre ; F. Barbagli ; A. Vicino ; F M Severi ; F. Petraglia

Source :

RBID : pubmed:17520599

English descriptors

Abstract

Ultrasound technologies have been widely used in gynecology and obstetrics. Modern ultrasound systems allow the reconstruction of a 3D model of the subject being scanned, but even though visual interfaces have reached very high standards, the problem of representing a 3D image on a 2D computer screen still exists. Moreover no physical interaction is possible with such a model. The FeTouch system, developed at Siena University in the last two years, partially solves such issues by using stereo visual feedback and haptic devices. While the system can be used with any 3D model obtained from ultrasound scans, its current prime use is to allow mothers to interact with a model of the fetus they are carrying. The system is freely available on the project web page.

DOI: 10.1002/rcs.9
PubMed: 17520599

Links to Exploration step

pubmed:17520599

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">The FeTouch project: an application of haptic technologies to obstetrics and gynaecology.</title>
<author>
<name sortKey="Prattichizzo, D" sort="Prattichizzo, D" uniqKey="Prattichizzo D" first="D" last="Prattichizzo">D. Prattichizzo</name>
<affiliation>
<nlm:affiliation>Dipartimento di Ingegneria dell'Informazione, Università di Siena, Italy. prattichizzo@ing.unisi.it</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="La Torre, B" sort="La Torre, B" uniqKey="La Torre B" first="B" last="La Torre">B. La Torre</name>
</author>
<author>
<name sortKey="Barbagli, F" sort="Barbagli, F" uniqKey="Barbagli F" first="F" last="Barbagli">F. Barbagli</name>
</author>
<author>
<name sortKey="Vicino, A" sort="Vicino, A" uniqKey="Vicino A" first="A" last="Vicino">A. Vicino</name>
</author>
<author>
<name sortKey="Severi, F M" sort="Severi, F M" uniqKey="Severi F" first="F M" last="Severi">F M Severi</name>
</author>
<author>
<name sortKey="Petraglia, F" sort="Petraglia, F" uniqKey="Petraglia F" first="F" last="Petraglia">F. Petraglia</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2004">2004</date>
<idno type="doi">10.1002/rcs.9</idno>
<idno type="RBID">pubmed:17520599</idno>
<idno type="pmid">17520599</idno>
<idno type="wicri:Area/PubMed/Corpus">001631</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">The FeTouch project: an application of haptic technologies to obstetrics and gynaecology.</title>
<author>
<name sortKey="Prattichizzo, D" sort="Prattichizzo, D" uniqKey="Prattichizzo D" first="D" last="Prattichizzo">D. Prattichizzo</name>
<affiliation>
<nlm:affiliation>Dipartimento di Ingegneria dell'Informazione, Università di Siena, Italy. prattichizzo@ing.unisi.it</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="La Torre, B" sort="La Torre, B" uniqKey="La Torre B" first="B" last="La Torre">B. La Torre</name>
</author>
<author>
<name sortKey="Barbagli, F" sort="Barbagli, F" uniqKey="Barbagli F" first="F" last="Barbagli">F. Barbagli</name>
</author>
<author>
<name sortKey="Vicino, A" sort="Vicino, A" uniqKey="Vicino A" first="A" last="Vicino">A. Vicino</name>
</author>
<author>
<name sortKey="Severi, F M" sort="Severi, F M" uniqKey="Severi F" first="F M" last="Severi">F M Severi</name>
</author>
<author>
<name sortKey="Petraglia, F" sort="Petraglia, F" uniqKey="Petraglia F" first="F" last="Petraglia">F. Petraglia</name>
</author>
</analytic>
<series>
<title level="j">The international journal of medical robotics + computer assisted surgery : MRCAS</title>
<idno type="eISSN">1478-596X</idno>
<imprint>
<date when="2004" type="published">2004</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Algorithms</term>
<term>Feedback</term>
<term>Female</term>
<term>Gynecology (methods)</term>
<term>Humans</term>
<term>Image Processing, Computer-Assisted</term>
<term>Imaging, Three-Dimensional</term>
<term>Models, Anatomic</term>
<term>Obstetrics (methods)</term>
<term>Pregnancy</term>
<term>Software</term>
<term>Touch</term>
<term>Ultrasonography</term>
<term>Ultrasonography, Prenatal</term>
<term>User-Computer Interface</term>
<term>Vision, Ocular</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en">
<term>Gynecology</term>
<term>Obstetrics</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Algorithms</term>
<term>Feedback</term>
<term>Female</term>
<term>Humans</term>
<term>Image Processing, Computer-Assisted</term>
<term>Imaging, Three-Dimensional</term>
<term>Models, Anatomic</term>
<term>Pregnancy</term>
<term>Software</term>
<term>Touch</term>
<term>Ultrasonography</term>
<term>Ultrasonography, Prenatal</term>
<term>User-Computer Interface</term>
<term>Vision, Ocular</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Ultrasound technologies have been widely used in gynecology and obstetrics. Modern ultrasound systems allow the reconstruction of a 3D model of the subject being scanned, but even though visual interfaces have reached very high standards, the problem of representing a 3D image on a 2D computer screen still exists. Moreover no physical interaction is possible with such a model. The FeTouch system, developed at Siena University in the last two years, partially solves such issues by using stereo visual feedback and haptic devices. While the system can be used with any 3D model obtained from ultrasound scans, its current prime use is to allow mothers to interact with a model of the fetus they are carrying. The system is freely available on the project web page.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="MEDLINE">
<PMID Version="1">17520599</PMID>
<DateCreated>
<Year>2007</Year>
<Month>05</Month>
<Day>23</Day>
</DateCreated>
<DateCompleted>
<Year>2007</Year>
<Month>06</Month>
<Day>05</Day>
</DateCompleted>
<DateRevised>
<Year>2008</Year>
<Month>11</Month>
<Day>21</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Electronic">1478-596X</ISSN>
<JournalIssue CitedMedium="Internet">
<Volume>1</Volume>
<Issue>1</Issue>
<PubDate>
<Year>2004</Year>
<Month>Jun</Month>
</PubDate>
</JournalIssue>
<Title>The international journal of medical robotics + computer assisted surgery : MRCAS</Title>
<ISOAbbreviation>Int J Med Robot</ISOAbbreviation>
</Journal>
<ArticleTitle>The FeTouch project: an application of haptic technologies to obstetrics and gynaecology.</ArticleTitle>
<Pagination>
<MedlinePgn>83-7</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText>Ultrasound technologies have been widely used in gynecology and obstetrics. Modern ultrasound systems allow the reconstruction of a 3D model of the subject being scanned, but even though visual interfaces have reached very high standards, the problem of representing a 3D image on a 2D computer screen still exists. Moreover no physical interaction is possible with such a model. The FeTouch system, developed at Siena University in the last two years, partially solves such issues by using stereo visual feedback and haptic devices. While the system can be used with any 3D model obtained from ultrasound scans, its current prime use is to allow mothers to interact with a model of the fetus they are carrying. The system is freely available on the project web page.</AbstractText>
<CopyrightInformation>Copyright 2004 Robotic Publications Ltd.</CopyrightInformation>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Prattichizzo</LastName>
<ForeName>D</ForeName>
<Initials>D</Initials>
<AffiliationInfo>
<Affiliation>Dipartimento di Ingegneria dell'Informazione, Università di Siena, Italy. prattichizzo@ing.unisi.it</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>la Torre</LastName>
<ForeName>B</ForeName>
<Initials>B</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Barbagli</LastName>
<ForeName>F</ForeName>
<Initials>F</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Vicino</LastName>
<ForeName>A</ForeName>
<Initials>A</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Severi</LastName>
<ForeName>F M</ForeName>
<Initials>FM</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Petraglia</LastName>
<ForeName>F</ForeName>
<Initials>F</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
<PublicationType UI="D013485">Research Support, Non-U.S. Gov't</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>England</Country>
<MedlineTA>Int J Med Robot</MedlineTA>
<NlmUniqueID>101250764</NlmUniqueID>
<ISSNLinking>1478-5951</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000465">Algorithms</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D005246">Feedback</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D005260">Female</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006176">Gynecology</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000379">methods</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D007091">Image Processing, Computer-Assisted</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D021621">Imaging, Three-Dimensional</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D008953">Models, Anatomic</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D009774">Obstetrics</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000379">methods</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D011247">Pregnancy</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D012984">Software</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D014110">Touch</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D014463">Ultrasonography</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D016216">Ultrasonography, Prenatal</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D014584">User-Computer Interface</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D014785">Vision, Ocular</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="pubmed">
<Year>2007</Year>
<Month>5</Month>
<Day>24</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2007</Year>
<Month>6</Month>
<Day>6</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>2007</Year>
<Month>5</Month>
<Day>24</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="doi">10.1002/rcs.9</ArticleId>
<ArticleId IdType="pubmed">17520599</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001631 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 001631 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    PubMed
   |étape=   Corpus
   |type=    RBID
   |clé=     pubmed:17520599
   |texte=   The FeTouch project: an application of haptic technologies to obstetrics and gynaecology.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i   -Sk "pubmed:17520599" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024