Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

[Refractive predictability and stability of three-piece versus single-piece intraocular lenses in patients with high axial myopia].

Identifieur interne : 000C04 ( PubMed/Corpus ); précédent : 000C03; suivant : 000C05

[Refractive predictability and stability of three-piece versus single-piece intraocular lenses in patients with high axial myopia].

Auteurs : A. Frings ; I. Steinbrugger ; E. Wissiak ; B. Vidic ; Y. El-Shabrawi ; N. Ardjomand

Source :

RBID : pubmed:22547125

English descriptors

Abstract

Based on previous data on single-piece and three-piece intraocular lenses (IOLs) there is no evidence for significant differences in decentration, tilt and refractive shift. The purpose of the current study was to compare single-piece and three-piece IOLs in patients with high axial myopia.

DOI: 10.1007/s00347-012-2556-5
PubMed: 22547125

Links to Exploration step

pubmed:22547125

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">[Refractive predictability and stability of three-piece versus single-piece intraocular lenses in patients with high axial myopia].</title>
<author>
<name sortKey="Frings, A" sort="Frings, A" uniqKey="Frings A" first="A" last="Frings">A. Frings</name>
<affiliation>
<nlm:affiliation>Universitäts-Augenklinik Graz, Medizinische Universität Graz, Auenbruggerplatz 4, 8036, Graz, Österreich.</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Steinbrugger, I" sort="Steinbrugger, I" uniqKey="Steinbrugger I" first="I" last="Steinbrugger">I. Steinbrugger</name>
</author>
<author>
<name sortKey="Wissiak, E" sort="Wissiak, E" uniqKey="Wissiak E" first="E" last="Wissiak">E. Wissiak</name>
</author>
<author>
<name sortKey="Vidic, B" sort="Vidic, B" uniqKey="Vidic B" first="B" last="Vidic">B. Vidic</name>
</author>
<author>
<name sortKey="El Shabrawi, Y" sort="El Shabrawi, Y" uniqKey="El Shabrawi Y" first="Y" last="El-Shabrawi">Y. El-Shabrawi</name>
</author>
<author>
<name sortKey="Ardjomand, N" sort="Ardjomand, N" uniqKey="Ardjomand N" first="N" last="Ardjomand">N. Ardjomand</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2012">2012</date>
<idno type="doi">10.1007/s00347-012-2556-5</idno>
<idno type="RBID">pubmed:22547125</idno>
<idno type="pmid">22547125</idno>
<idno type="wicri:Area/PubMed/Corpus">000C04</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">[Refractive predictability and stability of three-piece versus single-piece intraocular lenses in patients with high axial myopia].</title>
<author>
<name sortKey="Frings, A" sort="Frings, A" uniqKey="Frings A" first="A" last="Frings">A. Frings</name>
<affiliation>
<nlm:affiliation>Universitäts-Augenklinik Graz, Medizinische Universität Graz, Auenbruggerplatz 4, 8036, Graz, Österreich.</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Steinbrugger, I" sort="Steinbrugger, I" uniqKey="Steinbrugger I" first="I" last="Steinbrugger">I. Steinbrugger</name>
</author>
<author>
<name sortKey="Wissiak, E" sort="Wissiak, E" uniqKey="Wissiak E" first="E" last="Wissiak">E. Wissiak</name>
</author>
<author>
<name sortKey="Vidic, B" sort="Vidic, B" uniqKey="Vidic B" first="B" last="Vidic">B. Vidic</name>
</author>
<author>
<name sortKey="El Shabrawi, Y" sort="El Shabrawi, Y" uniqKey="El Shabrawi Y" first="Y" last="El-Shabrawi">Y. El-Shabrawi</name>
</author>
<author>
<name sortKey="Ardjomand, N" sort="Ardjomand, N" uniqKey="Ardjomand N" first="N" last="Ardjomand">N. Ardjomand</name>
</author>
</analytic>
<series>
<title level="j">Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft</title>
<idno type="eISSN">1433-0423</idno>
<imprint>
<date when="2012" type="published">2012</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Adult</term>
<term>Aged</term>
<term>Equipment Failure Analysis</term>
<term>Humans</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Myopia (complications)</term>
<term>Myopia (diagnosis)</term>
<term>Myopia (rehabilitation)</term>
<term>Prosthesis Design</term>
<term>Refractive Errors (diagnosis)</term>
<term>Refractive Errors (rehabilitation)</term>
<term>Treatment Outcome</term>
<term>Visual Acuity</term>
</keywords>
<keywords scheme="MESH" qualifier="complications" xml:lang="en">
<term>Myopia</term>
</keywords>
<keywords scheme="MESH" qualifier="diagnosis" xml:lang="en">
<term>Myopia</term>
<term>Refractive Errors</term>
</keywords>
<keywords scheme="MESH" qualifier="rehabilitation" xml:lang="en">
<term>Myopia</term>
<term>Refractive Errors</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Adult</term>
<term>Aged</term>
<term>Equipment Failure Analysis</term>
<term>Humans</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Prosthesis Design</term>
<term>Treatment Outcome</term>
<term>Visual Acuity</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Based on previous data on single-piece and three-piece intraocular lenses (IOLs) there is no evidence for significant differences in decentration, tilt and refractive shift. The purpose of the current study was to compare single-piece and three-piece IOLs in patients with high axial myopia.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="MEDLINE">
<PMID Version="1">22547125</PMID>
<DateCreated>
<Year>2012</Year>
<Month>06</Month>
<Day>15</Day>
</DateCreated>
<DateCompleted>
<Year>2012</Year>
<Month>11</Month>
<Day>09</Day>
</DateCompleted>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Electronic">1433-0423</ISSN>
<JournalIssue CitedMedium="Internet">
<Volume>109</Volume>
<Issue>6</Issue>
<PubDate>
<Year>2012</Year>
<Month>Jun</Month>
</PubDate>
</JournalIssue>
<Title>Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft</Title>
<ISOAbbreviation>Ophthalmologe</ISOAbbreviation>
</Journal>
<ArticleTitle>[Refractive predictability and stability of three-piece versus single-piece intraocular lenses in patients with high axial myopia].</ArticleTitle>
<Pagination>
<MedlinePgn>591-4</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1007/s00347-012-2556-5</ELocationID>
<Abstract>
<AbstractText Label="BACKGROUND" NlmCategory="BACKGROUND">Based on previous data on single-piece and three-piece intraocular lenses (IOLs) there is no evidence for significant differences in decentration, tilt and refractive shift. The purpose of the current study was to compare single-piece and three-piece IOLs in patients with high axial myopia.</AbstractText>
<AbstractText Label="MATERIAL AND METHODS" NlmCategory="METHODS">A total of 68 eyes of 50 patients with high axial myopia (axis length ≥ 28.00 mm) with and without cataract who underwent complication-free phacoemulsification and IOL implantation were retrospectively examined. To compare single-piece and three-piece IOLs, the patients were retrospectively grouped depending on IOL type: group 1 acrylic single-piece IOL (n = 37; ACR6D SE, Corneal, France) and group 2 acrylic three-piece IOL with fixed haptic frame (n = 31; AF-1 UY, Hoya, Japan). Patient files were analyzed regarding best spectacle-corrected visual acuity (BSCVA), refractive predictability and stability.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">In this study the mean BSCVA was determined as 0.22 ± 0.12 logMAR and 0.13 ± 0.11 logMAR 6 months postoperatively for the ACR6D SE group and the AF-1 UV group, respectively (p = 0.09). Refractive predictability was less accurate in the ACR6D SE (+ 1.75 ± 2.2 dpt) compared to the AF-1 UV (- 0.37 ± 1.1) treated eyes (p = 0.001). Refractive stability, defined as the difference in diopters between the first week and the sixth month after surgery, resulted in  + 0.40 ± 1.7 dpt and -0.16 ± 1.2 dpt for the ACR6D SE and the AF-1 UV, respectively (p = 0.022).</AbstractText>
<AbstractText Label="CONCLUSIONS" NlmCategory="CONCLUSIONS">The three-piece AF-1 UV showed satisfactory refractive predictability and stability in patients with high axial myopia. The ACR6D SE has a high refractive unpredictability and should not be used in eyes with high axial myopia.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Frings</LastName>
<ForeName>A</ForeName>
<Initials>A</Initials>
<AffiliationInfo>
<Affiliation>Universitäts-Augenklinik Graz, Medizinische Universität Graz, Auenbruggerplatz 4, 8036, Graz, Österreich.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Steinbrugger</LastName>
<ForeName>I</ForeName>
<Initials>I</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Wissiak</LastName>
<ForeName>E</ForeName>
<Initials>E</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Vidic</LastName>
<ForeName>B</ForeName>
<Initials>B</Initials>
</Author>
<Author ValidYN="Y">
<LastName>El-Shabrawi</LastName>
<ForeName>Y</ForeName>
<Initials>Y</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Ardjomand</LastName>
<ForeName>N</ForeName>
<Initials>N</Initials>
</Author>
</AuthorList>
<Language>ger</Language>
<PublicationTypeList>
<PublicationType UI="D003160">Comparative Study</PublicationType>
<PublicationType UI="D018848">Controlled Clinical Trial</PublicationType>
<PublicationType UI="D004740">English Abstract</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
<VernacularTitle>Refraktive Vorhersagbarkeit und Stabilität von 3-teiligen vs. 1-teiligen Intraokularlinsen bei hoher Achsenmyopie.</VernacularTitle>
</Article>
<MedlineJournalInfo>
<Country>Germany</Country>
<MedlineTA>Ophthalmologe</MedlineTA>
<NlmUniqueID>9206148</NlmUniqueID>
<ISSNLinking>0941-293X</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000328">Adult</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000368">Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D019544">Equipment Failure Analysis</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D007910">Lenses, Intraocular</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D008297">Male</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D008875">Middle Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D009216">Myopia</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000150">complications</QualifierName>
<QualifierName MajorTopicYN="Y" UI="Q000175">diagnosis</QualifierName>
<QualifierName MajorTopicYN="Y" UI="Q000534">rehabilitation</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D011474">Prosthesis Design</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D012030">Refractive Errors</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000175">diagnosis</QualifierName>
<QualifierName MajorTopicYN="Y" UI="Q000534">rehabilitation</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D016896">Treatment Outcome</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D014792">Visual Acuity</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="entrez">
<Year>2012</Year>
<Month>5</Month>
<Day>2</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2012</Year>
<Month>5</Month>
<Day>2</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2012</Year>
<Month>11</Month>
<Day>10</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="doi">10.1007/s00347-012-2556-5</ArticleId>
<ArticleId IdType="pubmed">22547125</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000C04 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 000C04 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    PubMed
   |étape=   Corpus
   |type=    RBID
   |clé=     pubmed:22547125
   |texte=   [Refractive predictability and stability of three-piece versus single-piece intraocular lenses in patients with high axial myopia].
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i   -Sk "pubmed:22547125" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024