Single-action implantation of a 3-piece acrylic intraocular lens with an injector.
Identifieur interne : 001904 ( PubMed/Checkpoint ); précédent : 001903; suivant : 001905Single-action implantation of a 3-piece acrylic intraocular lens with an injector.
Auteurs : Tetsuji Takeshita [Japon] ; Kazuhiro Yamada ; Hidenobu TaniharaSource :
- Journal of cataract and refractive surgery [ 0886-3350 ] ; 2003.
English descriptors
- KwdEn :
- MESH :
- chemical : Acrylic Resins, Biocompatible Materials.
- instrumentation : Lens Implantation, Intraocular.
- methods : Lens Implantation, Intraocular, Phacoemulsification.
- Aged, Aged, 80 and over, Female, Humans, Lenses, Intraocular, Male, Middle Aged.
Abstract
We report a method to insert a 3-piece AcrySof MA30BA acrylic foldable intraocular lens (IOL) (Alcon) in a single action using a Monarch II (Alcon) injector. The technique was used in 134 eyes. The incision widths ranged from 3.00 to 3.75 mm. The IOLs were successfully inserted in the capsular bag. Complications included cracks in the IOL optic in 3 eyes (3%), haptic damage in 3 eyes (3%), and inadequate self-sealing of the incision in 18 eyes (13%).
PubMed: 12648632
Affiliations:
Links toward previous steps (curation, corpus...)
Links to Exploration step
pubmed:12648632Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">Single-action implantation of a 3-piece acrylic intraocular lens with an injector.</title>
<author><name sortKey="Takeshita, Tetsuji" sort="Takeshita, Tetsuji" uniqKey="Takeshita T" first="Tetsuji" last="Takeshita">Tetsuji Takeshita</name>
<affiliation wicri:level="1"><nlm:affiliation>Department of Ophthalmology, Yamaga City Hospital, Kumamoto, Japan. takeshita@gpo.kumamoto-u.ac.jp</nlm:affiliation>
<country xml:lang="fr">Japon</country>
<wicri:regionArea>Department of Ophthalmology, Yamaga City Hospital, Kumamoto</wicri:regionArea>
<wicri:noRegion>Kumamoto</wicri:noRegion>
</affiliation>
</author>
<author><name sortKey="Yamada, Kazuhiro" sort="Yamada, Kazuhiro" uniqKey="Yamada K" first="Kazuhiro" last="Yamada">Kazuhiro Yamada</name>
</author>
<author><name sortKey="Tanihara, Hidenobu" sort="Tanihara, Hidenobu" uniqKey="Tanihara H" first="Hidenobu" last="Tanihara">Hidenobu Tanihara</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="2003">2003</date>
<idno type="RBID">pubmed:12648632</idno>
<idno type="pmid">12648632</idno>
<idno type="wicri:Area/PubMed/Corpus">001C23</idno>
<idno type="wicri:Area/PubMed/Curation">001C23</idno>
<idno type="wicri:Area/PubMed/Checkpoint">001904</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">Single-action implantation of a 3-piece acrylic intraocular lens with an injector.</title>
<author><name sortKey="Takeshita, Tetsuji" sort="Takeshita, Tetsuji" uniqKey="Takeshita T" first="Tetsuji" last="Takeshita">Tetsuji Takeshita</name>
<affiliation wicri:level="1"><nlm:affiliation>Department of Ophthalmology, Yamaga City Hospital, Kumamoto, Japan. takeshita@gpo.kumamoto-u.ac.jp</nlm:affiliation>
<country xml:lang="fr">Japon</country>
<wicri:regionArea>Department of Ophthalmology, Yamaga City Hospital, Kumamoto</wicri:regionArea>
<wicri:noRegion>Kumamoto</wicri:noRegion>
</affiliation>
</author>
<author><name sortKey="Yamada, Kazuhiro" sort="Yamada, Kazuhiro" uniqKey="Yamada K" first="Kazuhiro" last="Yamada">Kazuhiro Yamada</name>
</author>
<author><name sortKey="Tanihara, Hidenobu" sort="Tanihara, Hidenobu" uniqKey="Tanihara H" first="Hidenobu" last="Tanihara">Hidenobu Tanihara</name>
</author>
</analytic>
<series><title level="j">Journal of cataract and refractive surgery</title>
<idno type="ISSN">0886-3350</idno>
<imprint><date when="2003" type="published">2003</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Acrylic Resins</term>
<term>Aged</term>
<term>Aged, 80 and over</term>
<term>Biocompatible Materials</term>
<term>Female</term>
<term>Humans</term>
<term>Lens Implantation, Intraocular (instrumentation)</term>
<term>Lens Implantation, Intraocular (methods)</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Phacoemulsification (methods)</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en"><term>Acrylic Resins</term>
<term>Biocompatible Materials</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en"><term>Lens Implantation, Intraocular</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en"><term>Lens Implantation, Intraocular</term>
<term>Phacoemulsification</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Aged</term>
<term>Aged, 80 and over</term>
<term>Female</term>
<term>Humans</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Middle Aged</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">We report a method to insert a 3-piece AcrySof MA30BA acrylic foldable intraocular lens (IOL) (Alcon) in a single action using a Monarch II (Alcon) injector. The technique was used in 134 eyes. The incision widths ranged from 3.00 to 3.75 mm. The IOLs were successfully inserted in the capsular bag. Complications included cracks in the IOL optic in 3 eyes (3%), haptic damage in 3 eyes (3%), and inadequate self-sealing of the incision in 18 eyes (13%).</div>
</front>
</TEI>
<pubmed><MedlineCitation Owner="NLM" Status="MEDLINE"><PMID Version="1">12648632</PMID>
<DateCreated><Year>2003</Year>
<Month>03</Month>
<Day>21</Day>
</DateCreated>
<DateCompleted><Year>2003</Year>
<Month>04</Month>
<Day>07</Day>
</DateCompleted>
<DateRevised><Year>2004</Year>
<Month>11</Month>
<Day>17</Day>
</DateRevised>
<Article PubModel="Print"><Journal><ISSN IssnType="Print">0886-3350</ISSN>
<JournalIssue CitedMedium="Print"><Volume>29</Volume>
<Issue>2</Issue>
<PubDate><Year>2003</Year>
<Month>Feb</Month>
</PubDate>
</JournalIssue>
<Title>Journal of cataract and refractive surgery</Title>
<ISOAbbreviation>J Cataract Refract Surg</ISOAbbreviation>
</Journal>
<ArticleTitle>Single-action implantation of a 3-piece acrylic intraocular lens with an injector.</ArticleTitle>
<Pagination><MedlinePgn>246-9</MedlinePgn>
</Pagination>
<Abstract><AbstractText>We report a method to insert a 3-piece AcrySof MA30BA acrylic foldable intraocular lens (IOL) (Alcon) in a single action using a Monarch II (Alcon) injector. The technique was used in 134 eyes. The incision widths ranged from 3.00 to 3.75 mm. The IOLs were successfully inserted in the capsular bag. Complications included cracks in the IOL optic in 3 eyes (3%), haptic damage in 3 eyes (3%), and inadequate self-sealing of the incision in 18 eyes (13%).</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y"><Author ValidYN="Y"><LastName>Takeshita</LastName>
<ForeName>Tetsuji</ForeName>
<Initials>T</Initials>
<AffiliationInfo><Affiliation>Department of Ophthalmology, Yamaga City Hospital, Kumamoto, Japan. takeshita@gpo.kumamoto-u.ac.jp</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y"><LastName>Yamada</LastName>
<ForeName>Kazuhiro</ForeName>
<Initials>K</Initials>
</Author>
<Author ValidYN="Y"><LastName>Tanihara</LastName>
<ForeName>Hidenobu</ForeName>
<Initials>H</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList><PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo><Country>United States</Country>
<MedlineTA>J Cataract Refract Surg</MedlineTA>
<NlmUniqueID>8604171</NlmUniqueID>
<ISSNLinking>0886-3350</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList><Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D000180">Acrylic Resins</NameOfSubstance>
</Chemical>
<Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D001672">Biocompatible Materials</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList><MeshHeading><DescriptorName MajorTopicYN="Y" UI="D000180">Acrylic Resins</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D000368">Aged</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D000369">Aged, 80 and over</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D001672">Biocompatible Materials</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D005260">Female</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D019654">Lens Implantation, Intraocular</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000295">instrumentation</QualifierName>
<QualifierName MajorTopicYN="Y" UI="Q000379">methods</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="Y" UI="D007910">Lenses, Intraocular</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D008297">Male</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D008875">Middle Aged</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D018918">Phacoemulsification</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000379">methods</QualifierName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData><History><PubMedPubDate PubStatus="pubmed"><Year>2003</Year>
<Month>3</Month>
<Day>22</Day>
<Hour>4</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline"><Year>2003</Year>
<Month>4</Month>
<Day>8</Day>
<Hour>5</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez"><Year>2003</Year>
<Month>3</Month>
<Day>22</Day>
<Hour>4</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList><ArticleId IdType="pubmed">12648632</ArticleId>
<ArticleId IdType="pii">S0886335002014578</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
<affiliations><list><country><li>Japon</li>
</country>
</list>
<tree><noCountry><name sortKey="Tanihara, Hidenobu" sort="Tanihara, Hidenobu" uniqKey="Tanihara H" first="Hidenobu" last="Tanihara">Hidenobu Tanihara</name>
<name sortKey="Yamada, Kazuhiro" sort="Yamada, Kazuhiro" uniqKey="Yamada K" first="Kazuhiro" last="Yamada">Kazuhiro Yamada</name>
</noCountry>
<country name="Japon"><noRegion><name sortKey="Takeshita, Tetsuji" sort="Takeshita, Tetsuji" uniqKey="Takeshita T" first="Tetsuji" last="Takeshita">Tetsuji Takeshita</name>
</noRegion>
</country>
</tree>
</affiliations>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Checkpoint
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001904 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/PubMed/Checkpoint/biblio.hfd -nk 001904 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Ticri/CIDE |area= HapticV1 |flux= PubMed |étape= Checkpoint |type= RBID |clé= pubmed:12648632 |texte= Single-action implantation of a 3-piece acrylic intraocular lens with an injector. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Checkpoint/RBID.i -Sk "pubmed:12648632" \ | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Checkpoint/biblio.hfd \ | NlmPubMed2Wicri -a HapticV1
This area was generated with Dilib version V0.6.23. |