Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Factors influencing the radial-tangential illusion in haptic perception.

Identifieur interne : 001450 ( PubMed/Checkpoint ); précédent : 001449; suivant : 001451

Factors influencing the radial-tangential illusion in haptic perception.

Auteurs : James Mcfarland [États-Unis] ; John F. Soechting

Source :

RBID : pubmed:17053907

English descriptors

Abstract

According to the radial-tangential illusion, in the horizontal plane, arm movements executed in directions radial to the trunk are sensed to be longer than movements of the same length in the orthogonal direction. It has been suggested that the illusion arises from the fact that radially directed movements are executed more slowly and require more effort. These suggestions were tested in a series of experiments, using a robotically controlled manipulandum. In all of the experiments subjects grasped the handle of the manipulandum, in some cases exploring the virtual boundary of a rectangle, while in others being guided along a rectangular contour by the robot. In a two-alternative forced choice design, subjects reported whether the rectangle was wide or narrow. In a control experiment, subjects manifested the radial-tangential illusion. Contrary to the hypothesis, the magnitude of this illusion was not altered when a resistive force was added in the tangential direction or when the ratio of movement times in the tangential and radial directions was changed. However, when the contour was explored in the counterclockwise direction, the illusion was much smaller than when it was explored in the clockwise direction. A second series of experiments, in which subjects only explored two sides (i.e., an L-shape), demonstrated that this effect arose from distortions induced by the serial ordering of the exploratory movements. The illusion was much smaller when the radial segment was explored first. We suggest that this distortion arises from the serial nature of haptic exploration, in which the length of the initial segment decreases as it is stored in working memory for subsequent comparison.

DOI: 10.1007/s00221-006-0727-9
PubMed: 17053907


Affiliations:


Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:17053907

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Factors influencing the radial-tangential illusion in haptic perception.</title>
<author>
<name sortKey="Mcfarland, James" sort="Mcfarland, James" uniqKey="Mcfarland J" first="James" last="Mcfarland">James Mcfarland</name>
<affiliation wicri:level="2">
<nlm:affiliation>Department of Physics, Pomona College, Claremont, CA, USA.</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Department of Physics, Pomona College, Claremont, CA</wicri:regionArea>
<placeName>
<region type="state">Californie</region>
</placeName>
</affiliation>
</author>
<author>
<name sortKey="Soechting, John F" sort="Soechting, John F" uniqKey="Soechting J" first="John F" last="Soechting">John F. Soechting</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2007">2007</date>
<idno type="doi">10.1007/s00221-006-0727-9</idno>
<idno type="RBID">pubmed:17053907</idno>
<idno type="pmid">17053907</idno>
<idno type="wicri:Area/PubMed/Corpus">001741</idno>
<idno type="wicri:Area/PubMed/Curation">001741</idno>
<idno type="wicri:Area/PubMed/Checkpoint">001450</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Factors influencing the radial-tangential illusion in haptic perception.</title>
<author>
<name sortKey="Mcfarland, James" sort="Mcfarland, James" uniqKey="Mcfarland J" first="James" last="Mcfarland">James Mcfarland</name>
<affiliation wicri:level="2">
<nlm:affiliation>Department of Physics, Pomona College, Claremont, CA, USA.</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Department of Physics, Pomona College, Claremont, CA</wicri:regionArea>
<placeName>
<region type="state">Californie</region>
</placeName>
</affiliation>
</author>
<author>
<name sortKey="Soechting, John F" sort="Soechting, John F" uniqKey="Soechting J" first="John F" last="Soechting">John F. Soechting</name>
</author>
</analytic>
<series>
<title level="j">Experimental brain research</title>
<idno type="ISSN">0014-4819</idno>
<imprint>
<date when="2007" type="published">2007</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Attention</term>
<term>Distance Perception</term>
<term>Humans</term>
<term>Illusions</term>
<term>Kinesthesis</term>
<term>Movement (physiology)</term>
<term>Orientation</term>
<term>Perception (physiology)</term>
<term>Psychomotor Performance</term>
<term>Psychophysics</term>
<term>Touch</term>
</keywords>
<keywords scheme="MESH" qualifier="physiology" xml:lang="en">
<term>Movement</term>
<term>Perception</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Attention</term>
<term>Distance Perception</term>
<term>Humans</term>
<term>Illusions</term>
<term>Kinesthesis</term>
<term>Orientation</term>
<term>Psychomotor Performance</term>
<term>Psychophysics</term>
<term>Touch</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">According to the radial-tangential illusion, in the horizontal plane, arm movements executed in directions radial to the trunk are sensed to be longer than movements of the same length in the orthogonal direction. It has been suggested that the illusion arises from the fact that radially directed movements are executed more slowly and require more effort. These suggestions were tested in a series of experiments, using a robotically controlled manipulandum. In all of the experiments subjects grasped the handle of the manipulandum, in some cases exploring the virtual boundary of a rectangle, while in others being guided along a rectangular contour by the robot. In a two-alternative forced choice design, subjects reported whether the rectangle was wide or narrow. In a control experiment, subjects manifested the radial-tangential illusion. Contrary to the hypothesis, the magnitude of this illusion was not altered when a resistive force was added in the tangential direction or when the ratio of movement times in the tangential and radial directions was changed. However, when the contour was explored in the counterclockwise direction, the illusion was much smaller than when it was explored in the clockwise direction. A second series of experiments, in which subjects only explored two sides (i.e., an L-shape), demonstrated that this effect arose from distortions induced by the serial ordering of the exploratory movements. The illusion was much smaller when the radial segment was explored first. We suggest that this distortion arises from the serial nature of haptic exploration, in which the length of the initial segment decreases as it is stored in working memory for subsequent comparison.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="MEDLINE">
<PMID Version="1">17053907</PMID>
<DateCreated>
<Year>2007</Year>
<Month>03</Month>
<Day>19</Day>
</DateCreated>
<DateCompleted>
<Year>2008</Year>
<Month>01</Month>
<Day>04</Day>
</DateCompleted>
<DateRevised>
<Year>2013</Year>
<Month>12</Month>
<Day>13</Day>
</DateRevised>
<Article PubModel="Print-Electronic">
<Journal>
<ISSN IssnType="Print">0014-4819</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>178</Volume>
<Issue>2</Issue>
<PubDate>
<Year>2007</Year>
<Month>Apr</Month>
</PubDate>
</JournalIssue>
<Title>Experimental brain research</Title>
<ISOAbbreviation>Exp Brain Res</ISOAbbreviation>
</Journal>
<ArticleTitle>Factors influencing the radial-tangential illusion in haptic perception.</ArticleTitle>
<Pagination>
<MedlinePgn>216-27</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText>According to the radial-tangential illusion, in the horizontal plane, arm movements executed in directions radial to the trunk are sensed to be longer than movements of the same length in the orthogonal direction. It has been suggested that the illusion arises from the fact that radially directed movements are executed more slowly and require more effort. These suggestions were tested in a series of experiments, using a robotically controlled manipulandum. In all of the experiments subjects grasped the handle of the manipulandum, in some cases exploring the virtual boundary of a rectangle, while in others being guided along a rectangular contour by the robot. In a two-alternative forced choice design, subjects reported whether the rectangle was wide or narrow. In a control experiment, subjects manifested the radial-tangential illusion. Contrary to the hypothesis, the magnitude of this illusion was not altered when a resistive force was added in the tangential direction or when the ratio of movement times in the tangential and radial directions was changed. However, when the contour was explored in the counterclockwise direction, the illusion was much smaller than when it was explored in the clockwise direction. A second series of experiments, in which subjects only explored two sides (i.e., an L-shape), demonstrated that this effect arose from distortions induced by the serial ordering of the exploratory movements. The illusion was much smaller when the radial segment was explored first. We suggest that this distortion arises from the serial nature of haptic exploration, in which the length of the initial segment decreases as it is stored in working memory for subsequent comparison.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>McFarland</LastName>
<ForeName>James</ForeName>
<Initials>J</Initials>
<AffiliationInfo>
<Affiliation>Department of Physics, Pomona College, Claremont, CA, USA.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Soechting</LastName>
<ForeName>John F</ForeName>
<Initials>JF</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<GrantList CompleteYN="Y">
<Grant>
<GrantID>NS15018</GrantID>
<Acronym>NS</Acronym>
<Agency>NINDS NIH HHS</Agency>
<Country>United States</Country>
</Grant>
</GrantList>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
<PublicationType UI="D052061">Research Support, N.I.H., Extramural</PublicationType>
</PublicationTypeList>
<ArticleDate DateType="Electronic">
<Year>2006</Year>
<Month>10</Month>
<Day>12</Day>
</ArticleDate>
</Article>
<MedlineJournalInfo>
<Country>Germany</Country>
<MedlineTA>Exp Brain Res</MedlineTA>
<NlmUniqueID>0043312</NlmUniqueID>
<ISSNLinking>0014-4819</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D001288">Attention</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D004215">Distance Perception</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D007088">Illusions</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D007699">Kinesthesis</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D009068">Movement</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000502">physiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D009949">Orientation</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D010465">Perception</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000502">physiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D011597">Psychomotor Performance</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D011601">Psychophysics</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D014110">Touch</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="received">
<Year>2006</Year>
<Month>5</Month>
<Day>30</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="accepted">
<Year>2006</Year>
<Month>9</Month>
<Day>20</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="aheadofprint">
<Year>2006</Year>
<Month>10</Month>
<Day>12</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2006</Year>
<Month>10</Month>
<Day>21</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2008</Year>
<Month>1</Month>
<Day>5</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>2006</Year>
<Month>10</Month>
<Day>21</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="doi">10.1007/s00221-006-0727-9</ArticleId>
<ArticleId IdType="pubmed">17053907</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
<affiliations>
<list>
<country>
<li>États-Unis</li>
</country>
<region>
<li>Californie</li>
</region>
</list>
<tree>
<noCountry>
<name sortKey="Soechting, John F" sort="Soechting, John F" uniqKey="Soechting J" first="John F" last="Soechting">John F. Soechting</name>
</noCountry>
<country name="États-Unis">
<region name="Californie">
<name sortKey="Mcfarland, James" sort="Mcfarland, James" uniqKey="Mcfarland J" first="James" last="Mcfarland">James Mcfarland</name>
</region>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Checkpoint
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001450 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Checkpoint/biblio.hfd -nk 001450 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    PubMed
   |étape=   Checkpoint
   |type=    RBID
   |clé=     pubmed:17053907
   |texte=   Factors influencing the radial-tangential illusion in haptic perception.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Checkpoint/RBID.i   -Sk "pubmed:17053907" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Checkpoint/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024