A prototype haptic feedback system for lower-limb prostheses and sensory neuropathy.

Identifieur interne : 001336 ( PubMed/Checkpoint ); précédent : 001335; suivant : 001337

A prototype haptic feedback system for lower-limb prostheses and sensory neuropathy.

Auteurs : Richard E. Fan [États-Unis] ; Martin O. Culjat ; Chih-Hung King ; Miguel L. Franco ; Mark Sedrak ; James W. Bisley ; Erik P. Dutson ; Warren S. Grundfest

Source :

RBID : pubmed:18391269

Descripteurs français

English descriptors

Abstract

Lower-limb sensory loss as a result of peripheral neuropathy or amputation results in sub-optimal movement and an increased incidence of injury. While the adoption of lower-limb prostheses and therapeutic footwear can reduce tissue injury and support movement, the fundamental problem of sensory loss continues to exist. A prototype haptic feedback system has been developed to aid in the recovery of lower-limb sensation due to these causes. Thin-film force sensors placed at the critical points for gait and balance functions collect essential force data, which is delivered to the user via pneumatically controlled balloon inflation. It is postulated that the use of this system will increase the tactile awareness of a patient's lower-limb or prosthesis, and when used in concert with modern rehabilitation techniques will create a method that will reduce the duration and improve the quality of lower-limb rehabilitation, especially in gait and balance functions.

PubMed: 18391269


Affiliations:


Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:18391269

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">A prototype haptic feedback system for lower-limb prostheses and sensory neuropathy.</title>
<author>
<name sortKey="Fan, Richard E" sort="Fan, Richard E" uniqKey="Fan R" first="Richard E" last="Fan">Richard E. Fan</name>
<affiliation wicri:level="1">
<nlm:affiliation>Center for Advanced Surgical and Interventional Technology (CASIT), USA. rfan@ucla.edu</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Center for Advanced Surgical and Interventional Technology (CASIT)</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Culjat, Martin O" sort="Culjat, Martin O" uniqKey="Culjat M" first="Martin O" last="Culjat">Martin O. Culjat</name>
</author>
<author>
<name sortKey="King, Chih Hung" sort="King, Chih Hung" uniqKey="King C" first="Chih-Hung" last="King">Chih-Hung King</name>
</author>
<author>
<name sortKey="Franco, Miguel L" sort="Franco, Miguel L" uniqKey="Franco M" first="Miguel L" last="Franco">Miguel L. Franco</name>
</author>
<author>
<name sortKey="Sedrak, Mark" sort="Sedrak, Mark" uniqKey="Sedrak M" first="Mark" last="Sedrak">Mark Sedrak</name>
</author>
<author>
<name sortKey="Bisley, James W" sort="Bisley, James W" uniqKey="Bisley J" first="James W" last="Bisley">James W. Bisley</name>
</author>
<author>
<name sortKey="Dutson, Erik P" sort="Dutson, Erik P" uniqKey="Dutson E" first="Erik P" last="Dutson">Erik P. Dutson</name>
</author>
<author>
<name sortKey="Grundfest, Warren S" sort="Grundfest, Warren S" uniqKey="Grundfest W" first="Warren S" last="Grundfest">Warren S. Grundfest</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2008">2008</date>
<idno type="RBID">pubmed:18391269</idno>
<idno type="pmid">18391269</idno>
<idno type="wicri:Area/PubMed/Corpus">001483</idno>
<idno type="wicri:Area/PubMed/Curation">001483</idno>
<idno type="wicri:Area/PubMed/Checkpoint">001336</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">A prototype haptic feedback system for lower-limb prostheses and sensory neuropathy.</title>
<author>
<name sortKey="Fan, Richard E" sort="Fan, Richard E" uniqKey="Fan R" first="Richard E" last="Fan">Richard E. Fan</name>
<affiliation wicri:level="1">
<nlm:affiliation>Center for Advanced Surgical and Interventional Technology (CASIT), USA. rfan@ucla.edu</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Center for Advanced Surgical and Interventional Technology (CASIT)</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Culjat, Martin O" sort="Culjat, Martin O" uniqKey="Culjat M" first="Martin O" last="Culjat">Martin O. Culjat</name>
</author>
<author>
<name sortKey="King, Chih Hung" sort="King, Chih Hung" uniqKey="King C" first="Chih-Hung" last="King">Chih-Hung King</name>
</author>
<author>
<name sortKey="Franco, Miguel L" sort="Franco, Miguel L" uniqKey="Franco M" first="Miguel L" last="Franco">Miguel L. Franco</name>
</author>
<author>
<name sortKey="Sedrak, Mark" sort="Sedrak, Mark" uniqKey="Sedrak M" first="Mark" last="Sedrak">Mark Sedrak</name>
</author>
<author>
<name sortKey="Bisley, James W" sort="Bisley, James W" uniqKey="Bisley J" first="James W" last="Bisley">James W. Bisley</name>
</author>
<author>
<name sortKey="Dutson, Erik P" sort="Dutson, Erik P" uniqKey="Dutson E" first="Erik P" last="Dutson">Erik P. Dutson</name>
</author>
<author>
<name sortKey="Grundfest, Warren S" sort="Grundfest, Warren S" uniqKey="Grundfest W" first="Warren S" last="Grundfest">Warren S. Grundfest</name>
</author>
</analytic>
<series>
<title level="j">Studies in health technology and informatics</title>
<idno type="ISSN">0926-9630</idno>
<imprint>
<date when="2008" type="published">2008</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Equipment Design</term>
<term>Humans</term>
<term>Lower Extremity (innervation)</term>
<term>Lower Extremity (physiopathology)</term>
<term>Prostheses and Implants</term>
<term>Psychomotor Performance (physiology)</term>
<term>Touch</term>
<term>United States</term>
<term>User-Computer Interface</term>
</keywords>
<keywords scheme="MESH" type="geographic" xml:lang="en">
<term>United States</term>
</keywords>
<keywords scheme="MESH" qualifier="innervation" xml:lang="en">
<term>Lower Extremity</term>
</keywords>
<keywords scheme="MESH" qualifier="physiology" xml:lang="en">
<term>Psychomotor Performance</term>
</keywords>
<keywords scheme="MESH" qualifier="physiopathology" xml:lang="en">
<term>Lower Extremity</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Equipment Design</term>
<term>Humans</term>
<term>Prostheses and Implants</term>
<term>Touch</term>
<term>User-Computer Interface</term>
</keywords>
<keywords scheme="Wicri" type="geographic" xml:lang="fr">
<term>États-Unis</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Lower-limb sensory loss as a result of peripheral neuropathy or amputation results in sub-optimal movement and an increased incidence of injury. While the adoption of lower-limb prostheses and therapeutic footwear can reduce tissue injury and support movement, the fundamental problem of sensory loss continues to exist. A prototype haptic feedback system has been developed to aid in the recovery of lower-limb sensation due to these causes. Thin-film force sensors placed at the critical points for gait and balance functions collect essential force data, which is delivered to the user via pneumatically controlled balloon inflation. It is postulated that the use of this system will increase the tactile awareness of a patient's lower-limb or prosthesis, and when used in concert with modern rehabilitation techniques will create a method that will reduce the duration and improve the quality of lower-limb rehabilitation, especially in gait and balance functions.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="MEDLINE">
<PMID Version="1">18391269</PMID>
<DateCreated>
<Year>2008</Year>
<Month>04</Month>
<Day>08</Day>
</DateCreated>
<DateCompleted>
<Year>2008</Year>
<Month>05</Month>
<Day>27</Day>
</DateCompleted>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">0926-9630</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>132</Volume>
<PubDate>
<Year>2008</Year>
</PubDate>
</JournalIssue>
<Title>Studies in health technology and informatics</Title>
<ISOAbbreviation>Stud Health Technol Inform</ISOAbbreviation>
</Journal>
<ArticleTitle>A prototype haptic feedback system for lower-limb prostheses and sensory neuropathy.</ArticleTitle>
<Pagination>
<MedlinePgn>115-9</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText>Lower-limb sensory loss as a result of peripheral neuropathy or amputation results in sub-optimal movement and an increased incidence of injury. While the adoption of lower-limb prostheses and therapeutic footwear can reduce tissue injury and support movement, the fundamental problem of sensory loss continues to exist. A prototype haptic feedback system has been developed to aid in the recovery of lower-limb sensation due to these causes. Thin-film force sensors placed at the critical points for gait and balance functions collect essential force data, which is delivered to the user via pneumatically controlled balloon inflation. It is postulated that the use of this system will increase the tactile awareness of a patient's lower-limb or prosthesis, and when used in concert with modern rehabilitation techniques will create a method that will reduce the duration and improve the quality of lower-limb rehabilitation, especially in gait and balance functions.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Fan</LastName>
<ForeName>Richard E</ForeName>
<Initials>RE</Initials>
<AffiliationInfo>
<Affiliation>Center for Advanced Surgical and Interventional Technology (CASIT), USA. rfan@ucla.edu</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Culjat</LastName>
<ForeName>Martin O</ForeName>
<Initials>MO</Initials>
</Author>
<Author ValidYN="Y">
<LastName>King</LastName>
<ForeName>Chih-Hung</ForeName>
<Initials>CH</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Franco</LastName>
<ForeName>Miguel L</ForeName>
<Initials>ML</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Sedrak</LastName>
<ForeName>Mark</ForeName>
<Initials>M</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Bisley</LastName>
<ForeName>James W</ForeName>
<Initials>JW</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Dutson</LastName>
<ForeName>Erik P</ForeName>
<Initials>EP</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Grundfest</LastName>
<ForeName>Warren S</ForeName>
<Initials>WS</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
<PublicationType UI="D013485">Research Support, Non-U.S. Gov't</PublicationType>
<PublicationType UI="D013486">Research Support, U.S. Gov't, Non-P.H.S.</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>Netherlands</Country>
<MedlineTA>Stud Health Technol Inform</MedlineTA>
<NlmUniqueID>9214582</NlmUniqueID>
<ISSNLinking>0926-9630</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>T</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D004867">Equipment Design</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D035002">Lower Extremity</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000294">innervation</QualifierName>
<QualifierName MajorTopicYN="N" UI="Q000503">physiopathology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D019736">Prostheses and Implants</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D011597">Psychomotor Performance</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000502">physiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D014110">Touch</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" Type="Geographic" UI="D014481">United States</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D014584">User-Computer Interface</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="pubmed">
<Year>2008</Year>
<Month>4</Month>
<Day>9</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2008</Year>
<Month>5</Month>
<Day>28</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>2008</Year>
<Month>4</Month>
<Day>9</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">18391269</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
<affiliations>
<list>
<country>
<li>États-Unis</li>
</country>
</list>
<tree>
<noCountry>
<name sortKey="Bisley, James W" sort="Bisley, James W" uniqKey="Bisley J" first="James W" last="Bisley">James W. Bisley</name>
<name sortKey="Culjat, Martin O" sort="Culjat, Martin O" uniqKey="Culjat M" first="Martin O" last="Culjat">Martin O. Culjat</name>
<name sortKey="Dutson, Erik P" sort="Dutson, Erik P" uniqKey="Dutson E" first="Erik P" last="Dutson">Erik P. Dutson</name>
<name sortKey="Franco, Miguel L" sort="Franco, Miguel L" uniqKey="Franco M" first="Miguel L" last="Franco">Miguel L. Franco</name>
<name sortKey="Grundfest, Warren S" sort="Grundfest, Warren S" uniqKey="Grundfest W" first="Warren S" last="Grundfest">Warren S. Grundfest</name>
<name sortKey="King, Chih Hung" sort="King, Chih Hung" uniqKey="King C" first="Chih-Hung" last="King">Chih-Hung King</name>
<name sortKey="Sedrak, Mark" sort="Sedrak, Mark" uniqKey="Sedrak M" first="Mark" last="Sedrak">Mark Sedrak</name>
</noCountry>
<country name="États-Unis">
<noRegion>
<name sortKey="Fan, Richard E" sort="Fan, Richard E" uniqKey="Fan R" first="Richard E" last="Fan">Richard E. Fan</name>
</noRegion>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Checkpoint
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001336 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Checkpoint/biblio.hfd -nk 001336 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    PubMed
   |étape=   Checkpoint
   |type=    RBID
   |clé=     pubmed:18391269
   |texte=   A prototype haptic feedback system for lower-limb prostheses and sensory neuropathy.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Checkpoint/RBID.i   -Sk "pubmed:18391269" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Checkpoint/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024