Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Micro-force Sensing in Robot Assisted Membrane Peeling for Vitreoretinal Surgery

Identifieur interne : 001153 ( Pmc/Corpus ); précédent : 001152; suivant : 001154

Micro-force Sensing in Robot Assisted Membrane Peeling for Vitreoretinal Surgery

Auteurs : Marcin Balicki ; Ali Uneri ; Iulian Iordachita ; James Handa ; Peter Gehlbach ; Russell Taylor

Source :

RBID : PMC:3072686

Abstract

Vitreoretinal surgeons use 0.5mm diameter instruments to manipulate delicate tissue inside the eye while applying imperceptible forces that can cause damage to the retina. We present a system which robotically regulates user-applied forces to the tissue, to minimize the risk of retinal hemorrhage or tear during membrane peeling, a common task in vitreoretinal surgery. Our research platform is based on a cooperatively controlled microsurgery robot. It integrates a custom micro-force sensing surgical pick, which provides conventional surgical function and real time force information. We report the development of a new phantom, which is used to assess robot control, force feedback methods, and our newly implemented auditory sensory substitution to specifically assist membrane peeling. Our findings show that auditory sensory substitution decreased peeling forces in all tests, and that robotic force scaling with audio feedback is the most promising aid in reducing peeling forces and task completion time.


Url:
PubMed: 20879413
PubMed Central: 3072686

Links to Exploration step

PMC:3072686***** Acces problem to record *****\

Le document en format XML


Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Pmc/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001153 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd -nk 001153 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Pmc
   |étape=   Corpus
   |type=    RBID
   |clé=     PMC:3072686
   |texte=   Micro-force Sensing in Robot Assisted Membrane Peeling for Vitreoretinal Surgery
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/RBID.i   -Sk "pubmed:20879413" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024