Egocentric reference frame bias in the palmar haptic perception of surface orientation
Identifieur interne : 001231 ( PascalFrancis/Curation ); précédent : 001230; suivant : 001232Egocentric reference frame bias in the palmar haptic perception of surface orientation
Auteurs : Allison Coleman [États-Unis] ; Frank H. Durgin [États-Unis]Source :
- Psychonomic bulletin & review [ 1069-9384 ] ; 2014.
Descripteurs français
- Pascal (Inist)
- Wicri :
- topic : Homme.
English descriptors
- KwdEn :
Abstract
The effect of egocentric reference frames on palmar haptic perception of orientation was investigated in vertically separated locations in a sagittal plane. Reference stimuli to be haptically matched were presented either haptically (to the contralateral hand) or visually. As in prior investigations of haptic orientation perception, a strong egocentric bias was found, such that haptic orientation matches made in the lower part of personal space were much lower (i.e., were perceived as being higher) than those made at eye level. The same haptic bias was observed both when the reference surface to be matched was observed visually and when bimanual matching was used. These findings support the conclusion that, despite the presence of an unambiguous allocentric (gravitational) reference frame in vertical planes, haptic orientation perception in the sagittal plane reflects an egocentric bias.
pA |
|
---|
Links toward previous steps (curation, corpus...)
- to stream PascalFrancis, to step Corpus: Pour aller vers cette notice dans l'étape Curation :000032
- to stream PascalFrancis, to step Corpus: Pour aller vers cette notice dans l'étape Curation :000113
Links to Exploration step
Pascal:14-0223786Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en" level="a">Egocentric reference frame bias in the palmar haptic perception of surface orientation</title>
<author><name sortKey="Coleman, Allison" sort="Coleman, Allison" uniqKey="Coleman A" first="Allison" last="Coleman">Allison Coleman</name>
<affiliation wicri:level="1"><inist:fA14 i1="01"><s1>Department of Psychology, Swarthmore College, 500 College Avenue</s1>
<s2>Swarthmore, PA 19081</s2>
<s3>USA</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
</inist:fA14>
<country>États-Unis</country>
</affiliation>
</author>
<author><name sortKey="Durgin, Frank H" sort="Durgin, Frank H" uniqKey="Durgin F" first="Frank H." last="Durgin">Frank H. Durgin</name>
<affiliation wicri:level="1"><inist:fA14 i1="01"><s1>Department of Psychology, Swarthmore College, 500 College Avenue</s1>
<s2>Swarthmore, PA 19081</s2>
<s3>USA</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
</inist:fA14>
<country>États-Unis</country>
</affiliation>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">INIST</idno>
<idno type="inist">14-0223786</idno>
<date when="2014">2014</date>
<idno type="stanalyst">PASCAL 14-0223786 INIST</idno>
<idno type="RBID">Pascal:14-0223786</idno>
<idno type="wicri:Area/PascalFrancis/Corpus">000032</idno>
<idno type="stanalyst">FRANCIS 14-0223786 INIST</idno>
<idno type="wicri:Area/PascalFrancis/Corpus">000113</idno>
<idno type="wicri:Area/PascalFrancis/Curation">001231</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en" level="a">Egocentric reference frame bias in the palmar haptic perception of surface orientation</title>
<author><name sortKey="Coleman, Allison" sort="Coleman, Allison" uniqKey="Coleman A" first="Allison" last="Coleman">Allison Coleman</name>
<affiliation wicri:level="1"><inist:fA14 i1="01"><s1>Department of Psychology, Swarthmore College, 500 College Avenue</s1>
<s2>Swarthmore, PA 19081</s2>
<s3>USA</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
</inist:fA14>
<country>États-Unis</country>
</affiliation>
</author>
<author><name sortKey="Durgin, Frank H" sort="Durgin, Frank H" uniqKey="Durgin F" first="Frank H." last="Durgin">Frank H. Durgin</name>
<affiliation wicri:level="1"><inist:fA14 i1="01"><s1>Department of Psychology, Swarthmore College, 500 College Avenue</s1>
<s2>Swarthmore, PA 19081</s2>
<s3>USA</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
</inist:fA14>
<country>États-Unis</country>
</affiliation>
</author>
</analytic>
<series><title level="j" type="main">Psychonomic bulletin & review</title>
<title level="j" type="abbreviated">Psychon. bull. rev.</title>
<idno type="ISSN">1069-9384</idno>
<imprint><date when="2014">2014</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt><title level="j" type="main">Psychonomic bulletin & review</title>
<title level="j" type="abbreviated">Psychon. bull. rev.</title>
<idno type="ISSN">1069-9384</idno>
</seriesStmt>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Experimental study</term>
<term>Frame of reference</term>
<term>Human</term>
<term>Spatial cognition</term>
<term>Spatial orientation</term>
<term>Surface</term>
<term>Tactile sensitivity</term>
<term>Vision</term>
</keywords>
<keywords scheme="Pascal" xml:lang="fr"><term>Cadre de référence</term>
<term>Sensibilité tactile</term>
<term>Orientation spatiale</term>
<term>Surface</term>
<term>Cognition spatiale</term>
<term>Vision</term>
<term>Etude expérimentale</term>
<term>Homme</term>
</keywords>
<keywords scheme="Wicri" type="topic" xml:lang="fr"><term>Homme</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">The effect of egocentric reference frames on palmar haptic perception of orientation was investigated in vertically separated locations in a sagittal plane. Reference stimuli to be haptically matched were presented either haptically (to the contralateral hand) or visually. As in prior investigations of haptic orientation perception, a strong egocentric bias was found, such that haptic orientation matches made in the lower part of personal space were much lower (i.e., were perceived as being higher) than those made at eye level. The same haptic bias was observed both when the reference surface to be matched was observed visually and when bimanual matching was used. These findings support the conclusion that, despite the presence of an unambiguous allocentric (gravitational) reference frame in vertical planes, haptic orientation perception in the sagittal plane reflects an egocentric bias.</div>
</front>
</TEI>
<inist><standard h6="B"><pA><fA01 i1="01" i2="1"><s0>1069-9384</s0>
</fA01>
<fA03 i2="1"><s0>Psychon. bull. rev.</s0>
</fA03>
<fA05><s2>21</s2>
</fA05>
<fA06><s2>4</s2>
</fA06>
<fA08 i1="01" i2="1" l="ENG"><s1>Egocentric reference frame bias in the palmar haptic perception of surface orientation</s1>
</fA08>
<fA11 i1="01" i2="1"><s1>COLEMAN (Allison)</s1>
</fA11>
<fA11 i1="02" i2="1"><s1>DURGIN (Frank H.)</s1>
</fA11>
<fA14 i1="01"><s1>Department of Psychology, Swarthmore College, 500 College Avenue</s1>
<s2>Swarthmore, PA 19081</s2>
<s3>USA</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
</fA14>
<fA20><s1>955-960</s1>
</fA20>
<fA21><s1>2014</s1>
</fA21>
<fA23 i1="01"><s0>ENG</s0>
</fA23>
<fA43 i1="01"><s1>INIST</s1>
<s2>13280C</s2>
<s5>354000504842790070</s5>
</fA43>
<fA44><s0>0000</s0>
<s1>© 2014 INIST-CNRS. All rights reserved.</s1>
</fA44>
<fA45><s0>1/4 p.</s0>
</fA45>
<fA47 i1="01" i2="1"><s0>14-0223786</s0>
</fA47>
<fA60><s1>P</s1>
<s3>CC</s3>
</fA60>
<fA61><s0>A</s0>
</fA61>
<fA64 i1="01" i2="1"><s0>Psychonomic bulletin & review</s0>
</fA64>
<fA66 i1="01"><s0>USA</s0>
</fA66>
<fC01 i1="01" l="ENG"><s0>The effect of egocentric reference frames on palmar haptic perception of orientation was investigated in vertically separated locations in a sagittal plane. Reference stimuli to be haptically matched were presented either haptically (to the contralateral hand) or visually. As in prior investigations of haptic orientation perception, a strong egocentric bias was found, such that haptic orientation matches made in the lower part of personal space were much lower (i.e., were perceived as being higher) than those made at eye level. The same haptic bias was observed both when the reference surface to be matched was observed visually and when bimanual matching was used. These findings support the conclusion that, despite the presence of an unambiguous allocentric (gravitational) reference frame in vertical planes, haptic orientation perception in the sagittal plane reflects an egocentric bias.</s0>
</fC01>
<fC02 i1="01" i2="X"><s0>002A26E05</s0>
</fC02>
<fC02 i1="02" i2="X"><s0>002A26E03</s0>
</fC02>
<fC03 i1="01" i2="X" l="FRE"><s0>Cadre de référence</s0>
<s5>01</s5>
</fC03>
<fC03 i1="01" i2="X" l="ENG"><s0>Frame of reference</s0>
<s5>01</s5>
</fC03>
<fC03 i1="01" i2="X" l="SPA"><s0>Marco de referencia</s0>
<s5>01</s5>
</fC03>
<fC03 i1="02" i2="X" l="FRE"><s0>Sensibilité tactile</s0>
<s5>02</s5>
</fC03>
<fC03 i1="02" i2="X" l="ENG"><s0>Tactile sensitivity</s0>
<s5>02</s5>
</fC03>
<fC03 i1="02" i2="X" l="SPA"><s0>Sensibilidad tactil</s0>
<s5>02</s5>
</fC03>
<fC03 i1="03" i2="X" l="FRE"><s0>Orientation spatiale</s0>
<s5>03</s5>
</fC03>
<fC03 i1="03" i2="X" l="ENG"><s0>Spatial orientation</s0>
<s5>03</s5>
</fC03>
<fC03 i1="03" i2="X" l="SPA"><s0>Orientación espacial</s0>
<s5>03</s5>
</fC03>
<fC03 i1="04" i2="X" l="FRE"><s0>Surface</s0>
<s5>04</s5>
</fC03>
<fC03 i1="04" i2="X" l="ENG"><s0>Surface</s0>
<s5>04</s5>
</fC03>
<fC03 i1="04" i2="X" l="SPA"><s0>Superficie</s0>
<s5>04</s5>
</fC03>
<fC03 i1="05" i2="X" l="FRE"><s0>Cognition spatiale</s0>
<s5>06</s5>
</fC03>
<fC03 i1="05" i2="X" l="ENG"><s0>Spatial cognition</s0>
<s5>06</s5>
</fC03>
<fC03 i1="05" i2="X" l="SPA"><s0>Cognición espacial</s0>
<s5>06</s5>
</fC03>
<fC03 i1="06" i2="X" l="FRE"><s0>Vision</s0>
<s5>07</s5>
</fC03>
<fC03 i1="06" i2="X" l="ENG"><s0>Vision</s0>
<s5>07</s5>
</fC03>
<fC03 i1="06" i2="X" l="SPA"><s0>Visión</s0>
<s5>07</s5>
</fC03>
<fC03 i1="07" i2="X" l="FRE"><s0>Etude expérimentale</s0>
<s5>08</s5>
</fC03>
<fC03 i1="07" i2="X" l="ENG"><s0>Experimental study</s0>
<s5>08</s5>
</fC03>
<fC03 i1="07" i2="X" l="SPA"><s0>Estudio experimental</s0>
<s5>08</s5>
</fC03>
<fC03 i1="08" i2="X" l="FRE"><s0>Homme</s0>
<s5>18</s5>
</fC03>
<fC03 i1="08" i2="X" l="ENG"><s0>Human</s0>
<s5>18</s5>
</fC03>
<fC03 i1="08" i2="X" l="SPA"><s0>Hombre</s0>
<s5>18</s5>
</fC03>
<fC07 i1="01" i2="X" l="FRE"><s0>Perception</s0>
<s5>37</s5>
</fC07>
<fC07 i1="01" i2="X" l="ENG"><s0>Perception</s0>
<s5>37</s5>
</fC07>
<fC07 i1="01" i2="X" l="SPA"><s0>Percepción</s0>
<s5>37</s5>
</fC07>
<fN21><s1>272</s1>
</fN21>
</pA>
</standard>
</inist>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PascalFrancis/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001231 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/PascalFrancis/Curation/biblio.hfd -nk 001231 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Ticri/CIDE |area= HapticV1 |flux= PascalFrancis |étape= Curation |type= RBID |clé= Pascal:14-0223786 |texte= Egocentric reference frame bias in the palmar haptic perception of surface orientation }}
This area was generated with Dilib version V0.6.23. |