Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Single-action implantation of a 3-piece acrylic intraocular lens with an injector.

Identifieur interne : 000365 ( Ncbi/Merge ); précédent : 000364; suivant : 000366

Single-action implantation of a 3-piece acrylic intraocular lens with an injector.

Auteurs : Tetsuji Takeshita [Japon] ; Kazuhiro Yamada ; Hidenobu Tanihara

Source :

RBID : pubmed:12648632

English descriptors

Abstract

We report a method to insert a 3-piece AcrySof MA30BA acrylic foldable intraocular lens (IOL) (Alcon) in a single action using a Monarch II (Alcon) injector. The technique was used in 134 eyes. The incision widths ranged from 3.00 to 3.75 mm. The IOLs were successfully inserted in the capsular bag. Complications included cracks in the IOL optic in 3 eyes (3%), haptic damage in 3 eyes (3%), and inadequate self-sealing of the incision in 18 eyes (13%).

PubMed: 12648632

Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:12648632

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Single-action implantation of a 3-piece acrylic intraocular lens with an injector.</title>
<author>
<name sortKey="Takeshita, Tetsuji" sort="Takeshita, Tetsuji" uniqKey="Takeshita T" first="Tetsuji" last="Takeshita">Tetsuji Takeshita</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Ophthalmology, Yamaga City Hospital, Kumamoto, Japan. takeshita@gpo.kumamoto-u.ac.jp</nlm:affiliation>
<country xml:lang="fr">Japon</country>
<wicri:regionArea>Department of Ophthalmology, Yamaga City Hospital, Kumamoto</wicri:regionArea>
<wicri:noRegion>Kumamoto</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Yamada, Kazuhiro" sort="Yamada, Kazuhiro" uniqKey="Yamada K" first="Kazuhiro" last="Yamada">Kazuhiro Yamada</name>
</author>
<author>
<name sortKey="Tanihara, Hidenobu" sort="Tanihara, Hidenobu" uniqKey="Tanihara H" first="Hidenobu" last="Tanihara">Hidenobu Tanihara</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2003">2003</date>
<idno type="RBID">pubmed:12648632</idno>
<idno type="pmid">12648632</idno>
<idno type="wicri:Area/PubMed/Corpus">001C23</idno>
<idno type="wicri:Area/PubMed/Curation">001C23</idno>
<idno type="wicri:Area/PubMed/Checkpoint">001904</idno>
<idno type="wicri:Area/Ncbi/Merge">000365</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Single-action implantation of a 3-piece acrylic intraocular lens with an injector.</title>
<author>
<name sortKey="Takeshita, Tetsuji" sort="Takeshita, Tetsuji" uniqKey="Takeshita T" first="Tetsuji" last="Takeshita">Tetsuji Takeshita</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Ophthalmology, Yamaga City Hospital, Kumamoto, Japan. takeshita@gpo.kumamoto-u.ac.jp</nlm:affiliation>
<country xml:lang="fr">Japon</country>
<wicri:regionArea>Department of Ophthalmology, Yamaga City Hospital, Kumamoto</wicri:regionArea>
<wicri:noRegion>Kumamoto</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Yamada, Kazuhiro" sort="Yamada, Kazuhiro" uniqKey="Yamada K" first="Kazuhiro" last="Yamada">Kazuhiro Yamada</name>
</author>
<author>
<name sortKey="Tanihara, Hidenobu" sort="Tanihara, Hidenobu" uniqKey="Tanihara H" first="Hidenobu" last="Tanihara">Hidenobu Tanihara</name>
</author>
</analytic>
<series>
<title level="j">Journal of cataract and refractive surgery</title>
<idno type="ISSN">0886-3350</idno>
<imprint>
<date when="2003" type="published">2003</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Acrylic Resins</term>
<term>Aged</term>
<term>Aged, 80 and over</term>
<term>Biocompatible Materials</term>
<term>Female</term>
<term>Humans</term>
<term>Lens Implantation, Intraocular (instrumentation)</term>
<term>Lens Implantation, Intraocular (methods)</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Phacoemulsification (methods)</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en">
<term>Acrylic Resins</term>
<term>Biocompatible Materials</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en">
<term>Lens Implantation, Intraocular</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en">
<term>Lens Implantation, Intraocular</term>
<term>Phacoemulsification</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Aged</term>
<term>Aged, 80 and over</term>
<term>Female</term>
<term>Humans</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Middle Aged</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">We report a method to insert a 3-piece AcrySof MA30BA acrylic foldable intraocular lens (IOL) (Alcon) in a single action using a Monarch II (Alcon) injector. The technique was used in 134 eyes. The incision widths ranged from 3.00 to 3.75 mm. The IOLs were successfully inserted in the capsular bag. Complications included cracks in the IOL optic in 3 eyes (3%), haptic damage in 3 eyes (3%), and inadequate self-sealing of the incision in 18 eyes (13%).</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="MEDLINE">
<PMID Version="1">12648632</PMID>
<DateCreated>
<Year>2003</Year>
<Month>03</Month>
<Day>21</Day>
</DateCreated>
<DateCompleted>
<Year>2003</Year>
<Month>04</Month>
<Day>07</Day>
</DateCompleted>
<DateRevised>
<Year>2004</Year>
<Month>11</Month>
<Day>17</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">0886-3350</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>29</Volume>
<Issue>2</Issue>
<PubDate>
<Year>2003</Year>
<Month>Feb</Month>
</PubDate>
</JournalIssue>
<Title>Journal of cataract and refractive surgery</Title>
<ISOAbbreviation>J Cataract Refract Surg</ISOAbbreviation>
</Journal>
<ArticleTitle>Single-action implantation of a 3-piece acrylic intraocular lens with an injector.</ArticleTitle>
<Pagination>
<MedlinePgn>246-9</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText>We report a method to insert a 3-piece AcrySof MA30BA acrylic foldable intraocular lens (IOL) (Alcon) in a single action using a Monarch II (Alcon) injector. The technique was used in 134 eyes. The incision widths ranged from 3.00 to 3.75 mm. The IOLs were successfully inserted in the capsular bag. Complications included cracks in the IOL optic in 3 eyes (3%), haptic damage in 3 eyes (3%), and inadequate self-sealing of the incision in 18 eyes (13%).</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Takeshita</LastName>
<ForeName>Tetsuji</ForeName>
<Initials>T</Initials>
<AffiliationInfo>
<Affiliation>Department of Ophthalmology, Yamaga City Hospital, Kumamoto, Japan. takeshita@gpo.kumamoto-u.ac.jp</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Yamada</LastName>
<ForeName>Kazuhiro</ForeName>
<Initials>K</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Tanihara</LastName>
<ForeName>Hidenobu</ForeName>
<Initials>H</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>United States</Country>
<MedlineTA>J Cataract Refract Surg</MedlineTA>
<NlmUniqueID>8604171</NlmUniqueID>
<ISSNLinking>0886-3350</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D000180">Acrylic Resins</NameOfSubstance>
</Chemical>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D001672">Biocompatible Materials</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D000180">Acrylic Resins</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000368">Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000369">Aged, 80 and over</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D001672">Biocompatible Materials</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D005260">Female</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D019654">Lens Implantation, Intraocular</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000295">instrumentation</QualifierName>
<QualifierName MajorTopicYN="Y" UI="Q000379">methods</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D007910">Lenses, Intraocular</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D008297">Male</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D008875">Middle Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D018918">Phacoemulsification</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000379">methods</QualifierName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="pubmed">
<Year>2003</Year>
<Month>3</Month>
<Day>22</Day>
<Hour>4</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2003</Year>
<Month>4</Month>
<Day>8</Day>
<Hour>5</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>2003</Year>
<Month>3</Month>
<Day>22</Day>
<Hour>4</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">12648632</ArticleId>
<ArticleId IdType="pii">S0886335002014578</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
<affiliations>
<list>
<country>
<li>Japon</li>
</country>
</list>
<tree>
<noCountry>
<name sortKey="Tanihara, Hidenobu" sort="Tanihara, Hidenobu" uniqKey="Tanihara H" first="Hidenobu" last="Tanihara">Hidenobu Tanihara</name>
<name sortKey="Yamada, Kazuhiro" sort="Yamada, Kazuhiro" uniqKey="Yamada K" first="Kazuhiro" last="Yamada">Kazuhiro Yamada</name>
</noCountry>
<country name="Japon">
<noRegion>
<name sortKey="Takeshita, Tetsuji" sort="Takeshita, Tetsuji" uniqKey="Takeshita T" first="Tetsuji" last="Takeshita">Tetsuji Takeshita</name>
</noRegion>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Ncbi/Merge
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000365 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Ncbi/Merge/biblio.hfd -nk 000365 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Ncbi
   |étape=   Merge
   |type=    RBID
   |clé=     pubmed:12648632
   |texte=   Single-action implantation of a 3-piece acrylic intraocular lens with an injector.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Ncbi/Merge/RBID.i   -Sk "pubmed:12648632" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Ncbi/Merge/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024