Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Effect of haptic angulation on posterior capsule opacification in modern foldable lenses with a square, truncated optic edge.

Identifieur interne : 000306 ( Ncbi/Checkpoint ); précédent : 000305; suivant : 000307

Effect of haptic angulation on posterior capsule opacification in modern foldable lenses with a square, truncated optic edge.

Auteurs : Josef M. Schmidbauer [États-Unis] ; Marcela Escobar-Gomez ; David J. Apple ; Qun Peng ; Stella N. Arthur ; Luis G. Vargas

Source :

RBID : pubmed:12106736

English descriptors

Abstract

To analyze the effect of different haptic angulations on posterior capsule opacification (PCO) in a modern foldable intraocular lens (IOL) with a square-edged optic designed to reduce the incidence of PCO.

PubMed: 12106736


Affiliations:


Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:12106736

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Effect of haptic angulation on posterior capsule opacification in modern foldable lenses with a square, truncated optic edge.</title>
<author>
<name sortKey="Schmidbauer, Josef M" sort="Schmidbauer, Josef M" uniqKey="Schmidbauer J" first="Josef M" last="Schmidbauer">Josef M. Schmidbauer</name>
<affiliation wicri:level="1">
<nlm:affiliation>Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina 29425-5536, USA.</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina 29425-5536</wicri:regionArea>
<wicri:noRegion>South Carolina 29425-5536</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Escobar Gomez, Marcela" sort="Escobar Gomez, Marcela" uniqKey="Escobar Gomez M" first="Marcela" last="Escobar-Gomez">Marcela Escobar-Gomez</name>
</author>
<author>
<name sortKey="Apple, David J" sort="Apple, David J" uniqKey="Apple D" first="David J" last="Apple">David J. Apple</name>
</author>
<author>
<name sortKey="Peng, Qun" sort="Peng, Qun" uniqKey="Peng Q" first="Qun" last="Peng">Qun Peng</name>
</author>
<author>
<name sortKey="Arthur, Stella N" sort="Arthur, Stella N" uniqKey="Arthur S" first="Stella N" last="Arthur">Stella N. Arthur</name>
</author>
<author>
<name sortKey="Vargas, Luis G" sort="Vargas, Luis G" uniqKey="Vargas L" first="Luis G" last="Vargas">Luis G. Vargas</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2002">2002</date>
<idno type="RBID">pubmed:12106736</idno>
<idno type="pmid">12106736</idno>
<idno type="wicri:Area/PubMed/Corpus">001C71</idno>
<idno type="wicri:Area/PubMed/Curation">001C71</idno>
<idno type="wicri:Area/PubMed/Checkpoint">001A31</idno>
<idno type="wicri:Area/Ncbi/Merge">000306</idno>
<idno type="wicri:Area/Ncbi/Curation">000306</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">000306</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Effect of haptic angulation on posterior capsule opacification in modern foldable lenses with a square, truncated optic edge.</title>
<author>
<name sortKey="Schmidbauer, Josef M" sort="Schmidbauer, Josef M" uniqKey="Schmidbauer J" first="Josef M" last="Schmidbauer">Josef M. Schmidbauer</name>
<affiliation wicri:level="1">
<nlm:affiliation>Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina 29425-5536, USA.</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina 29425-5536</wicri:regionArea>
<wicri:noRegion>South Carolina 29425-5536</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Escobar Gomez, Marcela" sort="Escobar Gomez, Marcela" uniqKey="Escobar Gomez M" first="Marcela" last="Escobar-Gomez">Marcela Escobar-Gomez</name>
</author>
<author>
<name sortKey="Apple, David J" sort="Apple, David J" uniqKey="Apple D" first="David J" last="Apple">David J. Apple</name>
</author>
<author>
<name sortKey="Peng, Qun" sort="Peng, Qun" uniqKey="Peng Q" first="Qun" last="Peng">Qun Peng</name>
</author>
<author>
<name sortKey="Arthur, Stella N" sort="Arthur, Stella N" uniqKey="Arthur S" first="Stella N" last="Arthur">Stella N. Arthur</name>
</author>
<author>
<name sortKey="Vargas, Luis G" sort="Vargas, Luis G" uniqKey="Vargas L" first="Luis G" last="Vargas">Luis G. Vargas</name>
</author>
</analytic>
<series>
<title level="j">Journal of cataract and refractive surgery</title>
<idno type="ISSN">0886-3350</idno>
<imprint>
<date when="2002" type="published">2002</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Animals</term>
<term>Biocompatible Materials</term>
<term>Cataract (pathology)</term>
<term>Cataract (prevention & control)</term>
<term>Female</term>
<term>Lens Capsule, Crystalline (pathology)</term>
<term>Lens Implantation, Intraocular</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Phacoemulsification</term>
<term>Postoperative Complications (pathology)</term>
<term>Postoperative Complications (prevention & control)</term>
<term>Prosthesis Design</term>
<term>Rabbits</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en">
<term>Biocompatible Materials</term>
</keywords>
<keywords scheme="MESH" qualifier="pathology" xml:lang="en">
<term>Cataract</term>
<term>Lens Capsule, Crystalline</term>
<term>Postoperative Complications</term>
</keywords>
<keywords scheme="MESH" qualifier="prevention & control" xml:lang="en">
<term>Cataract</term>
<term>Postoperative Complications</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Animals</term>
<term>Female</term>
<term>Lens Implantation, Intraocular</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Phacoemulsification</term>
<term>Prosthesis Design</term>
<term>Rabbits</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">To analyze the effect of different haptic angulations on posterior capsule opacification (PCO) in a modern foldable intraocular lens (IOL) with a square-edged optic designed to reduce the incidence of PCO.</div>
</front>
</TEI>
<affiliations>
<list>
<country>
<li>États-Unis</li>
</country>
</list>
<tree>
<noCountry>
<name sortKey="Apple, David J" sort="Apple, David J" uniqKey="Apple D" first="David J" last="Apple">David J. Apple</name>
<name sortKey="Arthur, Stella N" sort="Arthur, Stella N" uniqKey="Arthur S" first="Stella N" last="Arthur">Stella N. Arthur</name>
<name sortKey="Escobar Gomez, Marcela" sort="Escobar Gomez, Marcela" uniqKey="Escobar Gomez M" first="Marcela" last="Escobar-Gomez">Marcela Escobar-Gomez</name>
<name sortKey="Peng, Qun" sort="Peng, Qun" uniqKey="Peng Q" first="Qun" last="Peng">Qun Peng</name>
<name sortKey="Vargas, Luis G" sort="Vargas, Luis G" uniqKey="Vargas L" first="Luis G" last="Vargas">Luis G. Vargas</name>
</noCountry>
<country name="États-Unis">
<noRegion>
<name sortKey="Schmidbauer, Josef M" sort="Schmidbauer, Josef M" uniqKey="Schmidbauer J" first="Josef M" last="Schmidbauer">Josef M. Schmidbauer</name>
</noRegion>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Ncbi/Checkpoint
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000306 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Ncbi/Checkpoint/biblio.hfd -nk 000306 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Ncbi
   |étape=   Checkpoint
   |type=    RBID
   |clé=     pubmed:12106736
   |texte=   Effect of haptic angulation on posterior capsule opacification in modern foldable lenses with a square, truncated optic edge.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Ncbi/Checkpoint/RBID.i   -Sk "pubmed:12106736" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Ncbi/Checkpoint/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024