Effect of haptic angulation on posterior capsule opacification in modern foldable lenses with a square, truncated optic edge.
Identifieur interne : 001C71 ( PubMed/Corpus ); précédent : 001C70; suivant : 001C72Effect of haptic angulation on posterior capsule opacification in modern foldable lenses with a square, truncated optic edge.
Auteurs : Josef M. Schmidbauer ; Marcela Escobar-Gomez ; David J. Apple ; Qun Peng ; Stella N. Arthur ; Luis G. VargasSource :
- Journal of cataract and refractive surgery [ 0886-3350 ] ; 2002.
English descriptors
- KwdEn :
- Animals, Biocompatible Materials, Cataract (pathology), Cataract (prevention & control), Female, Lens Capsule, Crystalline (pathology), Lens Implantation, Intraocular, Lenses, Intraocular, Male, Phacoemulsification, Postoperative Complications (pathology), Postoperative Complications (prevention & control), Prosthesis Design, Rabbits.
- MESH :
- chemical : Biocompatible Materials.
- pathology : Cataract, Lens Capsule, Crystalline, Postoperative Complications.
- prevention & control : Cataract, Postoperative Complications.
- Animals, Female, Lens Implantation, Intraocular, Lenses, Intraocular, Male, Phacoemulsification, Prosthesis Design, Rabbits.
Abstract
To analyze the effect of different haptic angulations on posterior capsule opacification (PCO) in a modern foldable intraocular lens (IOL) with a square-edged optic designed to reduce the incidence of PCO.
PubMed: 12106736
Links to Exploration step
pubmed:12106736Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">Effect of haptic angulation on posterior capsule opacification in modern foldable lenses with a square, truncated optic edge.</title>
<author><name sortKey="Schmidbauer, Josef M" sort="Schmidbauer, Josef M" uniqKey="Schmidbauer J" first="Josef M" last="Schmidbauer">Josef M. Schmidbauer</name>
<affiliation><nlm:affiliation>Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina 29425-5536, USA.</nlm:affiliation>
</affiliation>
</author>
<author><name sortKey="Escobar Gomez, Marcela" sort="Escobar Gomez, Marcela" uniqKey="Escobar Gomez M" first="Marcela" last="Escobar-Gomez">Marcela Escobar-Gomez</name>
</author>
<author><name sortKey="Apple, David J" sort="Apple, David J" uniqKey="Apple D" first="David J" last="Apple">David J. Apple</name>
</author>
<author><name sortKey="Peng, Qun" sort="Peng, Qun" uniqKey="Peng Q" first="Qun" last="Peng">Qun Peng</name>
</author>
<author><name sortKey="Arthur, Stella N" sort="Arthur, Stella N" uniqKey="Arthur S" first="Stella N" last="Arthur">Stella N. Arthur</name>
</author>
<author><name sortKey="Vargas, Luis G" sort="Vargas, Luis G" uniqKey="Vargas L" first="Luis G" last="Vargas">Luis G. Vargas</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="2002">2002</date>
<idno type="RBID">pubmed:12106736</idno>
<idno type="pmid">12106736</idno>
<idno type="wicri:Area/PubMed/Corpus">001C71</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">Effect of haptic angulation on posterior capsule opacification in modern foldable lenses with a square, truncated optic edge.</title>
<author><name sortKey="Schmidbauer, Josef M" sort="Schmidbauer, Josef M" uniqKey="Schmidbauer J" first="Josef M" last="Schmidbauer">Josef M. Schmidbauer</name>
<affiliation><nlm:affiliation>Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina 29425-5536, USA.</nlm:affiliation>
</affiliation>
</author>
<author><name sortKey="Escobar Gomez, Marcela" sort="Escobar Gomez, Marcela" uniqKey="Escobar Gomez M" first="Marcela" last="Escobar-Gomez">Marcela Escobar-Gomez</name>
</author>
<author><name sortKey="Apple, David J" sort="Apple, David J" uniqKey="Apple D" first="David J" last="Apple">David J. Apple</name>
</author>
<author><name sortKey="Peng, Qun" sort="Peng, Qun" uniqKey="Peng Q" first="Qun" last="Peng">Qun Peng</name>
</author>
<author><name sortKey="Arthur, Stella N" sort="Arthur, Stella N" uniqKey="Arthur S" first="Stella N" last="Arthur">Stella N. Arthur</name>
</author>
<author><name sortKey="Vargas, Luis G" sort="Vargas, Luis G" uniqKey="Vargas L" first="Luis G" last="Vargas">Luis G. Vargas</name>
</author>
</analytic>
<series><title level="j">Journal of cataract and refractive surgery</title>
<idno type="ISSN">0886-3350</idno>
<imprint><date when="2002" type="published">2002</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Animals</term>
<term>Biocompatible Materials</term>
<term>Cataract (pathology)</term>
<term>Cataract (prevention & control)</term>
<term>Female</term>
<term>Lens Capsule, Crystalline (pathology)</term>
<term>Lens Implantation, Intraocular</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Phacoemulsification</term>
<term>Postoperative Complications (pathology)</term>
<term>Postoperative Complications (prevention & control)</term>
<term>Prosthesis Design</term>
<term>Rabbits</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en"><term>Biocompatible Materials</term>
</keywords>
<keywords scheme="MESH" qualifier="pathology" xml:lang="en"><term>Cataract</term>
<term>Lens Capsule, Crystalline</term>
<term>Postoperative Complications</term>
</keywords>
<keywords scheme="MESH" qualifier="prevention & control" xml:lang="en"><term>Cataract</term>
<term>Postoperative Complications</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Animals</term>
<term>Female</term>
<term>Lens Implantation, Intraocular</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Phacoemulsification</term>
<term>Prosthesis Design</term>
<term>Rabbits</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">To analyze the effect of different haptic angulations on posterior capsule opacification (PCO) in a modern foldable intraocular lens (IOL) with a square-edged optic designed to reduce the incidence of PCO.</div>
</front>
</TEI>
<pubmed><MedlineCitation Owner="NLM" Status="MEDLINE"><PMID Version="1">12106736</PMID>
<DateCreated><Year>2002</Year>
<Month>07</Month>
<Day>10</Day>
</DateCreated>
<DateCompleted><Year>2002</Year>
<Month>09</Month>
<Day>09</Day>
</DateCompleted>
<DateRevised><Year>2010</Year>
<Month>03</Month>
<Day>23</Day>
</DateRevised>
<Article PubModel="Print"><Journal><ISSN IssnType="Print">0886-3350</ISSN>
<JournalIssue CitedMedium="Print"><Volume>28</Volume>
<Issue>7</Issue>
<PubDate><Year>2002</Year>
<Month>Jul</Month>
</PubDate>
</JournalIssue>
<Title>Journal of cataract and refractive surgery</Title>
<ISOAbbreviation>J Cataract Refract Surg</ISOAbbreviation>
</Journal>
<ArticleTitle>Effect of haptic angulation on posterior capsule opacification in modern foldable lenses with a square, truncated optic edge.</ArticleTitle>
<Pagination><MedlinePgn>1251-5</MedlinePgn>
</Pagination>
<Abstract><AbstractText Label="PURPOSE" NlmCategory="OBJECTIVE">To analyze the effect of different haptic angulations on posterior capsule opacification (PCO) in a modern foldable intraocular lens (IOL) with a square-edged optic designed to reduce the incidence of PCO.</AbstractText>
<AbstractText Label="SETTING" NlmCategory="METHODS">Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina, USA.</AbstractText>
<AbstractText Label="METHODS" NlmCategory="METHODS">Ten Dutch Belted, serum Pasteurella-free pigmented rabbits of the same age and sex had bilateral phacoemulsification with endocapsular IOL implantation. The eyes were implanted with Centerflex IOLs (Rayner) with haptic angulations of 0 degree (n = 8), 5 degrees (n = 4), 10 degrees (n = 4), or 15 degrees (n = 4).</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">There was no statistical difference in central PCO, peripheral PCO, and measured IOL decentration among the angulation groups.</AbstractText>
<AbstractText Label="CONCLUSION" NlmCategory="CONCLUSIONS">With the Centerflex IOL, haptic angulation did not seem to be a significant factor influencing PCO. It appears that the barrier effect of the IOL's truncated, square-edged optic overrides the angulation factor in preventing PCO.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y"><Author ValidYN="Y"><LastName>Schmidbauer</LastName>
<ForeName>Josef M</ForeName>
<Initials>JM</Initials>
<AffiliationInfo><Affiliation>Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina 29425-5536, USA.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y"><LastName>Escobar-Gomez</LastName>
<ForeName>Marcela</ForeName>
<Initials>M</Initials>
</Author>
<Author ValidYN="Y"><LastName>Apple</LastName>
<ForeName>David J</ForeName>
<Initials>DJ</Initials>
</Author>
<Author ValidYN="Y"><LastName>Peng</LastName>
<ForeName>Qun</ForeName>
<Initials>Q</Initials>
</Author>
<Author ValidYN="Y"><LastName>Arthur</LastName>
<ForeName>Stella N</ForeName>
<Initials>SN</Initials>
</Author>
<Author ValidYN="Y"><LastName>Vargas</LastName>
<ForeName>Luis G</ForeName>
<Initials>LG</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList><PublicationType UI="D016428">Journal Article</PublicationType>
<PublicationType UI="D013485">Research Support, Non-U.S. Gov't</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo><Country>United States</Country>
<MedlineTA>J Cataract Refract Surg</MedlineTA>
<NlmUniqueID>8604171</NlmUniqueID>
<ISSNLinking>0886-3350</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList><Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D001672">Biocompatible Materials</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList><MeshHeading><DescriptorName MajorTopicYN="N" UI="D000818">Animals</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D001672">Biocompatible Materials</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D002386">Cataract</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000473">pathology</QualifierName>
<QualifierName MajorTopicYN="N" UI="Q000517">prevention & control</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D005260">Female</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D007903">Lens Capsule, Crystalline</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000473">pathology</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="Y" UI="D019654">Lens Implantation, Intraocular</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="Y" UI="D007910">Lenses, Intraocular</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D008297">Male</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D018918">Phacoemulsification</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D011183">Postoperative Complications</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000473">pathology</QualifierName>
<QualifierName MajorTopicYN="N" UI="Q000517">prevention & control</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D011474">Prosthesis Design</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D011817">Rabbits</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData><History><PubMedPubDate PubStatus="pubmed"><Year>2002</Year>
<Month>7</Month>
<Day>11</Day>
<Hour>10</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline"><Year>2002</Year>
<Month>9</Month>
<Day>11</Day>
<Hour>10</Hour>
<Minute>1</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez"><Year>2002</Year>
<Month>7</Month>
<Day>11</Day>
<Hour>10</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList><ArticleId IdType="pubmed">12106736</ArticleId>
<ArticleId IdType="pii">S0886335002012142</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001C71 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 001C71 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Ticri/CIDE |area= HapticV1 |flux= PubMed |étape= Corpus |type= RBID |clé= pubmed:12106736 |texte= Effect of haptic angulation on posterior capsule opacification in modern foldable lenses with a square, truncated optic edge. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i -Sk "pubmed:12106736" \ | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd \ | NlmPubMed2Wicri -a HapticV1
![]() | This area was generated with Dilib version V0.6.23. | ![]() |