Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Human odometer is gait-symmetry specific

Identifieur interne : 004265 ( Main/Merge ); précédent : 004264; suivant : 004266

Human odometer is gait-symmetry specific

Auteurs : Michael T. Turvey ; Carissa Romaniak-Gross ; Robert W. Isenhower ; Ryan Arzamarski ; Steven Harrison ; Claudia Carello

Source :

RBID : PMC:2817097

Abstract

In 1709, Berkeley hypothesized of the human that distance is measurable by ‘the motion of his body, which is perceivable by touch’. To be sufficiently general and reliable, Berkeley's hypothesis must imply that distance measured by legged locomotion approximates actual distance, with the measure invariant to gait, speed and number of steps. We studied blindfolded human participants in a task in which they travelled by legged locomotion from a fixed starting point A to a variable terminus B, and then reproduced, by legged locomotion from B, the A–B distance. The outbound (‘measure’) and return (‘report’) gait could be the same or different, with similar or dissimilar step sizes and step frequencies. In five experiments we manipulated bipedal gait according to the primary versus secondary distinction revealed in symmetry group analyses of locomotion patterns. Berkeley's hypothesis held only when the measure and report gaits were of the same symmetry class, indicating that idiothetic distance measurement is gait-symmetry specific. Results suggest that human odometry (and perhaps animal odometry more generally) entails variables that encompass the limbs in coordination, such as global phase, and not variables at the level of the single limb, such as step length and step number, as traditionally assumed.


Url:
DOI: 10.1098/rspb.2009.1134
PubMed: 19740881
PubMed Central: 2817097

Links toward previous steps (curation, corpus...)


Links to Exploration step

PMC:2817097

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Human odometer is gait-symmetry specific</title>
<author>
<name sortKey="Turvey, Michael T" sort="Turvey, Michael T" uniqKey="Turvey M" first="Michael T." last="Turvey">Michael T. Turvey</name>
</author>
<author>
<name sortKey="Romaniak Gross, Carissa" sort="Romaniak Gross, Carissa" uniqKey="Romaniak Gross C" first="Carissa" last="Romaniak-Gross">Carissa Romaniak-Gross</name>
</author>
<author>
<name sortKey="Isenhower, Robert W" sort="Isenhower, Robert W" uniqKey="Isenhower R" first="Robert W." last="Isenhower">Robert W. Isenhower</name>
</author>
<author>
<name sortKey="Arzamarski, Ryan" sort="Arzamarski, Ryan" uniqKey="Arzamarski R" first="Ryan" last="Arzamarski">Ryan Arzamarski</name>
</author>
<author>
<name sortKey="Harrison, Steven" sort="Harrison, Steven" uniqKey="Harrison S" first="Steven" last="Harrison">Steven Harrison</name>
</author>
<author>
<name sortKey="Carello, Claudia" sort="Carello, Claudia" uniqKey="Carello C" first="Claudia" last="Carello">Claudia Carello</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PMC</idno>
<idno type="pmid">19740881</idno>
<idno type="pmc">2817097</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2817097</idno>
<idno type="RBID">PMC:2817097</idno>
<idno type="doi">10.1098/rspb.2009.1134</idno>
<date when="2009">2009</date>
<idno type="wicri:Area/Pmc/Corpus">001527</idno>
<idno type="wicri:Area/Pmc/Curation">001527</idno>
<idno type="wicri:Area/Pmc/Checkpoint">002139</idno>
<idno type="wicri:Area/Ncbi/Merge">001257</idno>
<idno type="wicri:Area/Ncbi/Curation">001257</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">001257</idno>
<idno type="wicri:doubleKey">0962-8452:2009:Turvey M:human:odometer:is</idno>
<idno type="wicri:Area/Main/Merge">004265</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a" type="main">Human odometer is gait-symmetry specific</title>
<author>
<name sortKey="Turvey, Michael T" sort="Turvey, Michael T" uniqKey="Turvey M" first="Michael T." last="Turvey">Michael T. Turvey</name>
</author>
<author>
<name sortKey="Romaniak Gross, Carissa" sort="Romaniak Gross, Carissa" uniqKey="Romaniak Gross C" first="Carissa" last="Romaniak-Gross">Carissa Romaniak-Gross</name>
</author>
<author>
<name sortKey="Isenhower, Robert W" sort="Isenhower, Robert W" uniqKey="Isenhower R" first="Robert W." last="Isenhower">Robert W. Isenhower</name>
</author>
<author>
<name sortKey="Arzamarski, Ryan" sort="Arzamarski, Ryan" uniqKey="Arzamarski R" first="Ryan" last="Arzamarski">Ryan Arzamarski</name>
</author>
<author>
<name sortKey="Harrison, Steven" sort="Harrison, Steven" uniqKey="Harrison S" first="Steven" last="Harrison">Steven Harrison</name>
</author>
<author>
<name sortKey="Carello, Claudia" sort="Carello, Claudia" uniqKey="Carello C" first="Claudia" last="Carello">Claudia Carello</name>
</author>
</analytic>
<series>
<title level="j">Proceedings of the Royal Society B: Biological Sciences</title>
<idno type="ISSN">0962-8452</idno>
<idno type="eISSN">1471-2954</idno>
<imprint>
<date when="2009">2009</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">
<p>In 1709, Berkeley hypothesized of the human that distance is measurable by ‘the motion of his body, which is perceivable by touch’. To be sufficiently general and reliable, Berkeley's hypothesis must imply that distance measured by legged locomotion approximates actual distance, with the measure invariant to gait, speed and number of steps. We studied blindfolded human participants in a task in which they travelled by legged locomotion from a fixed starting point A to a variable terminus B, and then reproduced, by legged locomotion from B, the A–B distance. The outbound (‘measure’) and return (‘report’) gait could be the same or different, with similar or dissimilar step sizes and step frequencies. In five experiments we manipulated bipedal gait according to the primary versus secondary distinction revealed in symmetry group analyses of locomotion patterns. Berkeley's hypothesis held only when the measure and report gaits were of the same symmetry class, indicating that idiothetic distance measurement is gait-symmetry specific. Results suggest that human odometry (and perhaps animal odometry more generally) entails variables that encompass the limbs in coordination, such as global phase, and not variables at the level of the single limb, such as step length and step number, as traditionally assumed.</p>
</div>
</front>
</TEI>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Main/Merge
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 004265 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Merge/biblio.hfd -nk 004265 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Main
   |étape=   Merge
   |type=    RBID
   |clé=     PMC:2817097
   |texte=   Human odometer is gait-symmetry specific
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Merge/RBID.i   -Sk "pubmed:19740881" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Merge/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024