Position Control of Motion Compensation Cardiac Catheters

Identifieur interne : 002A54 ( Main/Merge ); précédent : 002A53; suivant : 002A55

Position Control of Motion Compensation Cardiac Catheters

Auteurs : Samuel B. Kesner ; Robert D. Howe

Source :

RBID : PMC:3160644

Abstract

Robotic catheters have the potential to revolutionize cardiac surgery by enabling minimally invasive structural repairs within the beating heart. This paper presents an actuated catheter system that compensates for the fast motion of cardiac tissue using 3D ultrasound image guidance. We describe the design and operation of the mechanical drive system and catheter module and analyze the catheter performance limitations of friction and backlash in detail. To mitigate these limitations, we propose and evaluate mechanical and control system compensation methods, including inverse and model-based backlash compensation, to improve the system performance. Finally, in vivo results are presented that demonstrate that the catheter can track the cardiac tissue motion with less than 1 mm RMS error. The ultimate goal of this research is to create a fast and dexterous robotic catheter system that can perform surgery on the delicate structures inside of the beating heart.


Url:
DOI: 10.1109/TRO.2011.2160467
PubMed: 21874124
PubMed Central: 3160644

Links toward previous steps (curation, corpus...)


Links to Exploration step

PMC:3160644

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Position Control of Motion Compensation Cardiac Catheters</title>
<author>
<name sortKey="Kesner, Samuel B" sort="Kesner, Samuel B" uniqKey="Kesner S" first="Samuel B." last="Kesner">Samuel B. Kesner</name>
</author>
<author>
<name sortKey="Howe, Robert D" sort="Howe, Robert D" uniqKey="Howe R" first="Robert D." last="Howe">Robert D. Howe</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PMC</idno>
<idno type="pmid">21874124</idno>
<idno type="pmc">3160644</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3160644</idno>
<idno type="RBID">PMC:3160644</idno>
<idno type="doi">10.1109/TRO.2011.2160467</idno>
<date when="2011">2011</date>
<idno type="wicri:Area/Pmc/Corpus">001161</idno>
<idno type="wicri:Area/Pmc/Curation">001161</idno>
<idno type="wicri:Area/Pmc/Checkpoint">001A33</idno>
<idno type="wicri:Area/Ncbi/Merge">001B67</idno>
<idno type="wicri:Area/Ncbi/Curation">001B67</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">001B67</idno>
<idno type="wicri:doubleKey">1552-3098:2011:Kesner S:position:control:of</idno>
<idno type="wicri:Area/Main/Merge">002A54</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a" type="main">Position Control of Motion Compensation Cardiac Catheters</title>
<author>
<name sortKey="Kesner, Samuel B" sort="Kesner, Samuel B" uniqKey="Kesner S" first="Samuel B." last="Kesner">Samuel B. Kesner</name>
</author>
<author>
<name sortKey="Howe, Robert D" sort="Howe, Robert D" uniqKey="Howe R" first="Robert D." last="Howe">Robert D. Howe</name>
</author>
</analytic>
<series>
<title level="j">IEEE transactions on robotics : a publication of the IEEE Robotics and Automation Society</title>
<idno type="ISSN">1552-3098</idno>
<idno type="eISSN">1941-0468</idno>
<imprint>
<date when="2011">2011</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">
<p id="P1">Robotic catheters have the potential to revolutionize cardiac surgery by enabling minimally invasive structural repairs within the beating heart. This paper presents an actuated catheter system that compensates for the fast motion of cardiac tissue using 3D ultrasound image guidance. We describe the design and operation of the mechanical drive system and catheter module and analyze the catheter performance limitations of friction and backlash in detail. To mitigate these limitations, we propose and evaluate mechanical and control system compensation methods, including inverse and model-based backlash compensation, to improve the system performance. Finally, in vivo results are presented that demonstrate that the catheter can track the cardiac tissue motion with less than 1 mm RMS error. The ultimate goal of this research is to create a fast and dexterous robotic catheter system that can perform surgery on the delicate structures inside of the beating heart.</p>
</div>
</front>
</TEI>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Main/Merge
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 002A54 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Merge/biblio.hfd -nk 002A54 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Main
   |étape=   Merge
   |type=    RBID
   |clé=     PMC:3160644
   |texte=   Position Control of Motion Compensation Cardiac Catheters
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Merge/RBID.i   -Sk "pubmed:21874124" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Merge/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024