Long-term results and biocompatibility of heparin-surface-modified intraocular lenses.

Identifieur interne : 009327 ( Main/Exploration ); précédent : 009326; suivant : 009328

Long-term results and biocompatibility of heparin-surface-modified intraocular lenses.

Auteurs : M. Amon [Autriche] ; R. Menapace

Source :

RBID : pubmed:8487171

English descriptors

Abstract

A prospective in vivo study of 50 intraocular lenses was done to document the long-term results and biocompatibility of heparin-surface-modified poly(methyl methacrylate) posterior chamber lenses. Continuous curvilinear capsulorhexis and phacoemulsification were performed throughout and examinations were by slit-lamp and specular microscopy. Decentrations of more than 1 mm were seen in 4% of eyes. Stress folds from the haptic traction forces were detected in 16%. A posterior capsulotomy was performed in 10% because of fibrosis or Elschnig pearl formation. Fine fibers were found on the lens surface in 76%. During the first postoperative days only a moderate number of fibroblast-like cells was observed. Foreign-body giant cells were seen in 8%. All cases with foreign-body giant cells had posterior synechias. Visual performance and clinical results were comparable to those of other well-approved intraocular lenses. The low percentage of cellular reaction on the lens surface suggests good biocompatibility.

PubMed: 8487171


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Long-term results and biocompatibility of heparin-surface-modified intraocular lenses.</title>
<author>
<name sortKey="Amon, M" sort="Amon, M" uniqKey="Amon M" first="M" last="Amon">M. Amon</name>
<affiliation wicri:level="3">
<nlm:affiliation>1. Universität Augenklinik Wien, Vienna, Austria.</nlm:affiliation>
<country xml:lang="fr">Autriche</country>
<wicri:regionArea>1. Universität Augenklinik Wien, Vienna</wicri:regionArea>
<placeName>
<settlement type="city">Vienne (Autriche)</settlement>
<region nuts="2" type="province">Vienne (Autriche)</region>
</placeName>
</affiliation>
</author>
<author>
<name sortKey="Menapace, R" sort="Menapace, R" uniqKey="Menapace R" first="R" last="Menapace">R. Menapace</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="1993">1993</date>
<idno type="RBID">pubmed:8487171</idno>
<idno type="pmid">8487171</idno>
<idno type="wicri:Area/PubMed/Corpus">002168</idno>
<idno type="wicri:Area/PubMed/Curation">002168</idno>
<idno type="wicri:Area/PubMed/Checkpoint">001E87</idno>
<idno type="wicri:Area/Ncbi/Merge">004571</idno>
<idno type="wicri:Area/Ncbi/Curation">004571</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">004571</idno>
<idno type="wicri:doubleKey">0886-3350:1993:Amon M:long:term:results</idno>
<idno type="wicri:Area/Main/Merge">009D16</idno>
<idno type="wicri:Area/Main/Curation">009327</idno>
<idno type="wicri:Area/Main/Exploration">009327</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Long-term results and biocompatibility of heparin-surface-modified intraocular lenses.</title>
<author>
<name sortKey="Amon, M" sort="Amon, M" uniqKey="Amon M" first="M" last="Amon">M. Amon</name>
<affiliation wicri:level="3">
<nlm:affiliation>1. Universität Augenklinik Wien, Vienna, Austria.</nlm:affiliation>
<country xml:lang="fr">Autriche</country>
<wicri:regionArea>1. Universität Augenklinik Wien, Vienna</wicri:regionArea>
<placeName>
<settlement type="city">Vienne (Autriche)</settlement>
<region nuts="2" type="province">Vienne (Autriche)</region>
</placeName>
</affiliation>
</author>
<author>
<name sortKey="Menapace, R" sort="Menapace, R" uniqKey="Menapace R" first="R" last="Menapace">R. Menapace</name>
</author>
</analytic>
<series>
<title level="j">Journal of cataract and refractive surgery</title>
<idno type="ISSN">0886-3350</idno>
<imprint>
<date when="1993" type="published">1993</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Adult</term>
<term>Aged</term>
<term>Aged, 80 and over</term>
<term>Biocompatible Materials</term>
<term>Cataract Extraction</term>
<term>Female</term>
<term>Fibroblasts (pathology)</term>
<term>Foreign-Body Reaction (pathology)</term>
<term>Giant Cells (pathology)</term>
<term>Heparin</term>
<term>Humans</term>
<term>Lenses, Intraocular</term>
<term>Longitudinal Studies</term>
<term>Male</term>
<term>Methylmethacrylate</term>
<term>Methylmethacrylates</term>
<term>Middle Aged</term>
<term>Prospective Studies</term>
<term>Prosthesis Design</term>
<term>Treatment Outcome</term>
<term>Visual Acuity</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en">
<term>Biocompatible Materials</term>
<term>Heparin</term>
<term>Methylmethacrylate</term>
<term>Methylmethacrylates</term>
</keywords>
<keywords scheme="MESH" qualifier="pathology" xml:lang="en">
<term>Fibroblasts</term>
<term>Foreign-Body Reaction</term>
<term>Giant Cells</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Adult</term>
<term>Aged</term>
<term>Aged, 80 and over</term>
<term>Cataract Extraction</term>
<term>Female</term>
<term>Humans</term>
<term>Lenses, Intraocular</term>
<term>Longitudinal Studies</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Prospective Studies</term>
<term>Prosthesis Design</term>
<term>Treatment Outcome</term>
<term>Visual Acuity</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">A prospective in vivo study of 50 intraocular lenses was done to document the long-term results and biocompatibility of heparin-surface-modified poly(methyl methacrylate) posterior chamber lenses. Continuous curvilinear capsulorhexis and phacoemulsification were performed throughout and examinations were by slit-lamp and specular microscopy. Decentrations of more than 1 mm were seen in 4% of eyes. Stress folds from the haptic traction forces were detected in 16%. A posterior capsulotomy was performed in 10% because of fibrosis or Elschnig pearl formation. Fine fibers were found on the lens surface in 76%. During the first postoperative days only a moderate number of fibroblast-like cells was observed. Foreign-body giant cells were seen in 8%. All cases with foreign-body giant cells had posterior synechias. Visual performance and clinical results were comparable to those of other well-approved intraocular lenses. The low percentage of cellular reaction on the lens surface suggests good biocompatibility.</div>
</front>
</TEI>
<affiliations>
<list>
<country>
<li>Autriche</li>
</country>
<region>
<li>Vienne (Autriche)</li>
</region>
<settlement>
<li>Vienne (Autriche)</li>
</settlement>
</list>
<tree>
<noCountry>
<name sortKey="Menapace, R" sort="Menapace, R" uniqKey="Menapace R" first="R" last="Menapace">R. Menapace</name>
</noCountry>
<country name="Autriche">
<region name="Vienne (Autriche)">
<name sortKey="Amon, M" sort="Amon, M" uniqKey="Amon M" first="M" last="Amon">M. Amon</name>
</region>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 009327 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 009327 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     pubmed:8487171
   |texte=   Long-term results and biocompatibility of heparin-surface-modified intraocular lenses.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Exploration/RBID.i   -Sk "pubmed:8487171" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024