System characterization of a novel haptic interface for natural orifice translumenal endoscopic surgery simulation.
Identifieur interne : 000E04 ( Main/Exploration ); précédent : 000E03; suivant : 000E05System characterization of a novel haptic interface for natural orifice translumenal endoscopic surgery simulation.
Auteurs : Saurabh Dargar ; Ganesh Sankaranarayanan ; Suvranu DeSource :
- Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference [ 1557-170X ] ; 2014.
English descriptors
- KwdEn :
- MESH :
Abstract
Natural orifice translumenal endoscopic surgery (NOTES) is a minimally invasive procedure, which utilizes the body's natural orifices to gain access to the peritoneal cavity. The VTEST(©) is a virtual reality NOTES simulator developed at the CeMSIM at RPI to train surgeons in NOTES. A novel 2 DOF decoupled haptic device was designed and built for this simulator. The haptic device can render 5.62 N and 190.05 N-mm of continuous force and torque respectively. In this work we have evaluated the haptic interface and developed a model to accurately describe the system behavior, to further incorporate into an impedance type controller for realistic haptic rendering in the VTEST(©).
DOI: 10.1109/EMBC.2014.6943607
PubMed: 25569975
Affiliations:
Links toward previous steps (curation, corpus...)
- to stream PubMed, to step Corpus: 000451
- to stream PubMed, to step Curation: 000451
- to stream PubMed, to step Checkpoint: 000523
- to stream Ncbi, to step Merge: 003596
- to stream Ncbi, to step Curation: 003596
- to stream Ncbi, to step Checkpoint: 003596
- to stream Main, to step Merge: 000E03
- to stream Main, to step Curation: 000E04
Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">System characterization of a novel haptic interface for natural orifice translumenal endoscopic surgery simulation.</title>
<author><name sortKey="Dargar, Saurabh" sort="Dargar, Saurabh" uniqKey="Dargar S" first="Saurabh" last="Dargar">Saurabh Dargar</name>
</author>
<author><name sortKey="Sankaranarayanan, Ganesh" sort="Sankaranarayanan, Ganesh" uniqKey="Sankaranarayanan G" first="Ganesh" last="Sankaranarayanan">Ganesh Sankaranarayanan</name>
</author>
<author><name sortKey="De, Suvranu" sort="De, Suvranu" uniqKey="De S" first="Suvranu" last="De">Suvranu De</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="2014">2014</date>
<idno type="doi">10.1109/EMBC.2014.6943607</idno>
<idno type="RBID">pubmed:25569975</idno>
<idno type="pmid">25569975</idno>
<idno type="wicri:Area/PubMed/Corpus">000451</idno>
<idno type="wicri:Area/PubMed/Curation">000451</idno>
<idno type="wicri:Area/PubMed/Checkpoint">000523</idno>
<idno type="wicri:Area/Ncbi/Merge">003596</idno>
<idno type="wicri:Area/Ncbi/Curation">003596</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">003596</idno>
<idno type="wicri:doubleKey">1557-170X:2014:Dargar S:system:characterization:of</idno>
<idno type="wicri:Area/Main/Merge">000E03</idno>
<idno type="wicri:Area/Main/Curation">000E04</idno>
<idno type="wicri:Area/Main/Exploration">000E04</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">System characterization of a novel haptic interface for natural orifice translumenal endoscopic surgery simulation.</title>
<author><name sortKey="Dargar, Saurabh" sort="Dargar, Saurabh" uniqKey="Dargar S" first="Saurabh" last="Dargar">Saurabh Dargar</name>
</author>
<author><name sortKey="Sankaranarayanan, Ganesh" sort="Sankaranarayanan, Ganesh" uniqKey="Sankaranarayanan G" first="Ganesh" last="Sankaranarayanan">Ganesh Sankaranarayanan</name>
</author>
<author><name sortKey="De, Suvranu" sort="De, Suvranu" uniqKey="De S" first="Suvranu" last="De">Suvranu De</name>
</author>
</analytic>
<series><title level="j">Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference</title>
<idno type="ISSN">1557-170X</idno>
<imprint><date when="2014" type="published">2014</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Computer Simulation</term>
<term>Computer-Aided Design</term>
<term>Humans</term>
<term>Natural Orifice Endoscopic Surgery</term>
<term>Rotation</term>
<term>Software</term>
<term>Touch</term>
<term>User-Computer Interface</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Computer Simulation</term>
<term>Computer-Aided Design</term>
<term>Humans</term>
<term>Natural Orifice Endoscopic Surgery</term>
<term>Rotation</term>
<term>Software</term>
<term>Touch</term>
<term>User-Computer Interface</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">Natural orifice translumenal endoscopic surgery (NOTES) is a minimally invasive procedure, which utilizes the body's natural orifices to gain access to the peritoneal cavity. The VTEST(©) is a virtual reality NOTES simulator developed at the CeMSIM at RPI to train surgeons in NOTES. A novel 2 DOF decoupled haptic device was designed and built for this simulator. The haptic device can render 5.62 N and 190.05 N-mm of continuous force and torque respectively. In this work we have evaluated the haptic interface and developed a model to accurately describe the system behavior, to further incorporate into an impedance type controller for realistic haptic rendering in the VTEST(©).</div>
</front>
</TEI>
<affiliations><list></list>
<tree><noCountry><name sortKey="Dargar, Saurabh" sort="Dargar, Saurabh" uniqKey="Dargar S" first="Saurabh" last="Dargar">Saurabh Dargar</name>
<name sortKey="De, Suvranu" sort="De, Suvranu" uniqKey="De S" first="Suvranu" last="De">Suvranu De</name>
<name sortKey="Sankaranarayanan, Ganesh" sort="Sankaranarayanan, Ganesh" uniqKey="Sankaranarayanan G" first="Ganesh" last="Sankaranarayanan">Ganesh Sankaranarayanan</name>
</noCountry>
</tree>
</affiliations>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000E04 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 000E04 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Ticri/CIDE |area= HapticV1 |flux= Main |étape= Exploration |type= RBID |clé= pubmed:25569975 |texte= System characterization of a novel haptic interface for natural orifice translumenal endoscopic surgery simulation. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Exploration/RBID.i -Sk "pubmed:25569975" \ | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd \ | NlmPubMed2Wicri -a HapticV1
This area was generated with Dilib version V0.6.23. |