Broadband measurement of translational and angular vibrations using a single continuously scanning laser Doppler vibrometer.
Identifieur interne : 002533 ( Main/Exploration ); précédent : 002532; suivant : 002534Broadband measurement of translational and angular vibrations using a single continuously scanning laser Doppler vibrometer.
Auteurs : Muhammad Salman [États-Unis] ; Karim G. SabraSource :
- The Journal of the Acoustical Society of America [ 1520-8524 ] ; 2012.
English descriptors
- KwdEn :
- Adult, Biomechanical Phenomena, Gelatin, Hand, Humans, Laser-Doppler Flowmetry (instrumentation), Linear Models, Male, Muscle Contraction, Muscle Fatigue, Muscle, Skeletal (physiopathology), Phantoms, Imaging, Reproducibility of Results, Signal Processing, Computer-Assisted, Tremor (physiopathology), Vibration.
- MESH :
- chemical : Gelatin.
- instrumentation : Laser-Doppler Flowmetry.
- physiopathology : Muscle, Skeletal, Tremor.
- Adult, Biomechanical Phenomena, Hand, Humans, Linear Models, Male, Muscle Contraction, Muscle Fatigue, Phantoms, Imaging, Reproducibility of Results, Signal Processing, Computer-Assisted, Vibration.
Abstract
A continuous scanning laser Doppler velocimetry (CSLDV) technique is used to measure the low frequency broadband vibrations associated with human skeletal muscle vibrations (typically f < 100 Hz) by continuously varying the orientation of laser beam over distances that are short compared to the characteristic wavelengths of the vibrations. The high frequency scan (compared to the vibration frequency) enables the detection of broadband translational and angular velocities at a single point using amplitude demodulation of the CSDLV signal. For instance, linear scans allow measurement of the normal surface velocity and one component of angular velocity vector, while circular scans allow measurement of an additional angular velocity component. This CSLDV technique is first validated here using gel samples mimicking soft tissues and then applied to measure multiple degrees of freedom (DOF) of a subject's hand exhibiting fatigue-induced tremor. Hence this CSLDV technique potentially provides a means for measuring multiple DOF of small human body parts (e.g., fingers, tendons, small muscles) for various applications (e.g., haptic technology, remote surgery) when the use of skin-mounted sensors (e.g. accelerometers) can be problematic due to mass-loading artifacts or tethering issues.
DOI: 10.1121/1.4740473
PubMed: 22978867
Affiliations:
Links toward previous steps (curation, corpus...)
- to stream PubMed, to step Corpus: 000B29
- to stream PubMed, to step Curation: 000B29
- to stream PubMed, to step Checkpoint: 000B82
- to stream Ncbi, to step Merge: 002243
- to stream Ncbi, to step Curation: 002243
- to stream Ncbi, to step Checkpoint: 002243
- to stream Main, to step Merge: 002560
- to stream Main, to step Curation: 002533
Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">Broadband measurement of translational and angular vibrations using a single continuously scanning laser Doppler vibrometer.</title>
<author><name sortKey="Salman, Muhammad" sort="Salman, Muhammad" uniqKey="Salman M" first="Muhammad" last="Salman">Muhammad Salman</name>
<affiliation wicri:level="1"><nlm:affiliation>Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332, USA. msalman.usa@gatech.edu</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332</wicri:regionArea>
<wicri:noRegion>Georgia 30332</wicri:noRegion>
</affiliation>
</author>
<author><name sortKey="Sabra, Karim G" sort="Sabra, Karim G" uniqKey="Sabra K" first="Karim G" last="Sabra">Karim G. Sabra</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="2012">2012</date>
<idno type="doi">10.1121/1.4740473</idno>
<idno type="RBID">pubmed:22978867</idno>
<idno type="pmid">22978867</idno>
<idno type="wicri:Area/PubMed/Corpus">000B29</idno>
<idno type="wicri:Area/PubMed/Curation">000B29</idno>
<idno type="wicri:Area/PubMed/Checkpoint">000B82</idno>
<idno type="wicri:Area/Ncbi/Merge">002243</idno>
<idno type="wicri:Area/Ncbi/Curation">002243</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">002243</idno>
<idno type="wicri:Area/Main/Merge">002560</idno>
<idno type="wicri:Area/Main/Curation">002533</idno>
<idno type="wicri:Area/Main/Exploration">002533</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">Broadband measurement of translational and angular vibrations using a single continuously scanning laser Doppler vibrometer.</title>
<author><name sortKey="Salman, Muhammad" sort="Salman, Muhammad" uniqKey="Salman M" first="Muhammad" last="Salman">Muhammad Salman</name>
<affiliation wicri:level="1"><nlm:affiliation>Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332, USA. msalman.usa@gatech.edu</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332</wicri:regionArea>
<wicri:noRegion>Georgia 30332</wicri:noRegion>
</affiliation>
</author>
<author><name sortKey="Sabra, Karim G" sort="Sabra, Karim G" uniqKey="Sabra K" first="Karim G" last="Sabra">Karim G. Sabra</name>
</author>
</analytic>
<series><title level="j">The Journal of the Acoustical Society of America</title>
<idno type="eISSN">1520-8524</idno>
<imprint><date when="2012" type="published">2012</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Adult</term>
<term>Biomechanical Phenomena</term>
<term>Gelatin</term>
<term>Hand</term>
<term>Humans</term>
<term>Laser-Doppler Flowmetry (instrumentation)</term>
<term>Linear Models</term>
<term>Male</term>
<term>Muscle Contraction</term>
<term>Muscle Fatigue</term>
<term>Muscle, Skeletal (physiopathology)</term>
<term>Phantoms, Imaging</term>
<term>Reproducibility of Results</term>
<term>Signal Processing, Computer-Assisted</term>
<term>Tremor (physiopathology)</term>
<term>Vibration</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en"><term>Gelatin</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en"><term>Laser-Doppler Flowmetry</term>
</keywords>
<keywords scheme="MESH" qualifier="physiopathology" xml:lang="en"><term>Muscle, Skeletal</term>
<term>Tremor</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Adult</term>
<term>Biomechanical Phenomena</term>
<term>Hand</term>
<term>Humans</term>
<term>Linear Models</term>
<term>Male</term>
<term>Muscle Contraction</term>
<term>Muscle Fatigue</term>
<term>Phantoms, Imaging</term>
<term>Reproducibility of Results</term>
<term>Signal Processing, Computer-Assisted</term>
<term>Vibration</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">A continuous scanning laser Doppler velocimetry (CSLDV) technique is used to measure the low frequency broadband vibrations associated with human skeletal muscle vibrations (typically f < 100 Hz) by continuously varying the orientation of laser beam over distances that are short compared to the characteristic wavelengths of the vibrations. The high frequency scan (compared to the vibration frequency) enables the detection of broadband translational and angular velocities at a single point using amplitude demodulation of the CSDLV signal. For instance, linear scans allow measurement of the normal surface velocity and one component of angular velocity vector, while circular scans allow measurement of an additional angular velocity component. This CSLDV technique is first validated here using gel samples mimicking soft tissues and then applied to measure multiple degrees of freedom (DOF) of a subject's hand exhibiting fatigue-induced tremor. Hence this CSLDV technique potentially provides a means for measuring multiple DOF of small human body parts (e.g., fingers, tendons, small muscles) for various applications (e.g., haptic technology, remote surgery) when the use of skin-mounted sensors (e.g. accelerometers) can be problematic due to mass-loading artifacts or tethering issues.</div>
</front>
</TEI>
<affiliations><list><country><li>États-Unis</li>
</country>
</list>
<tree><noCountry><name sortKey="Sabra, Karim G" sort="Sabra, Karim G" uniqKey="Sabra K" first="Karim G" last="Sabra">Karim G. Sabra</name>
</noCountry>
<country name="États-Unis"><noRegion><name sortKey="Salman, Muhammad" sort="Salman, Muhammad" uniqKey="Salman M" first="Muhammad" last="Salman">Muhammad Salman</name>
</noRegion>
</country>
</tree>
</affiliations>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 002533 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 002533 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Ticri/CIDE |area= HapticV1 |flux= Main |étape= Exploration |type= RBID |clé= pubmed:22978867 |texte= Broadband measurement of translational and angular vibrations using a single continuously scanning laser Doppler vibrometer. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Exploration/RBID.i -Sk "pubmed:22978867" \ | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd \ | NlmPubMed2Wicri -a HapticV1
This area was generated with Dilib version V0.6.23. |