Sufficiency of longitudinal moment of inertia for haptic cylinder length judgments.
Identifieur interne : 003529 ( Main/Exploration ); précédent : 003528; suivant : 003530Sufficiency of longitudinal moment of inertia for haptic cylinder length judgments.
Auteurs : Patrick A. Cabe [États-Unis]Source :
- Journal of experimental psychology. Human perception and performance [ 1939-1277 ] ; 2010.
English descriptors
- KwdEn :
- MESH :
Abstract
Many studies invoke moment of inertia (Iii) as necessary and sufficient information to perceive cylinder length via wielding, yet some assert that Iii is neither necessary (weight, m, or static moment, M, are sufficient) nor sufficient for length judgments (m or M is necessary). Mathematical expressions for Iii not involving m or M imply length, so Iii could be sufficient for cylinder length judgments. In 5 experiments (N = 113), only longitudinal Iii (the smallest principal value) informed cylinder length estimates in a novel task, rolling. Experiment 1 yielded reliable length judgments. Varying diameter supported length scaling (Experiment 2); similar length estimates occurred with both rolling and wielding (Experiment 3); feedback improved rolling length judgments to levels commensurate with wielding (Experiment 4); and length judgments shifted predictably with added mass (Experiment 5). Contrary to proposals in the literature, Iii is sufficient information for cylinder length judgments, absent m or M information, even when Iii is of minimal magnitude and the task quite novel.
DOI: 10.1037/a0018395
PubMed: 20364925
Affiliations:
Links toward previous steps (curation, corpus...)
- to stream PubMed, to step Corpus: 001115
- to stream PubMed, to step Curation: 001115
- to stream PubMed, to step Checkpoint: 000E76
- to stream Ncbi, to step Merge: 001492
- to stream Ncbi, to step Curation: 001492
- to stream Ncbi, to step Checkpoint: 001492
- to stream Main, to step Merge: 003578
- to stream Main, to step Curation: 003529
Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">Sufficiency of longitudinal moment of inertia for haptic cylinder length judgments.</title>
<author><name sortKey="Cabe, Patrick A" sort="Cabe, Patrick A" uniqKey="Cabe P" first="Patrick A" last="Cabe">Patrick A. Cabe</name>
<affiliation wicri:level="1"><nlm:affiliation>Department of Psychology, University of North Carolina at Pembroke, USA. patrick.cabe@uncp.edu</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Department of Psychology, University of North Carolina at Pembroke</wicri:regionArea>
<wicri:noRegion>University of North Carolina at Pembroke</wicri:noRegion>
</affiliation>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="2010">2010</date>
<idno type="doi">10.1037/a0018395</idno>
<idno type="RBID">pubmed:20364925</idno>
<idno type="pmid">20364925</idno>
<idno type="wicri:Area/PubMed/Corpus">001115</idno>
<idno type="wicri:Area/PubMed/Curation">001115</idno>
<idno type="wicri:Area/PubMed/Checkpoint">000E76</idno>
<idno type="wicri:Area/Ncbi/Merge">001492</idno>
<idno type="wicri:Area/Ncbi/Curation">001492</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">001492</idno>
<idno type="wicri:Area/Main/Merge">003578</idno>
<idno type="wicri:Area/Main/Curation">003529</idno>
<idno type="wicri:Area/Main/Exploration">003529</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">Sufficiency of longitudinal moment of inertia for haptic cylinder length judgments.</title>
<author><name sortKey="Cabe, Patrick A" sort="Cabe, Patrick A" uniqKey="Cabe P" first="Patrick A" last="Cabe">Patrick A. Cabe</name>
<affiliation wicri:level="1"><nlm:affiliation>Department of Psychology, University of North Carolina at Pembroke, USA. patrick.cabe@uncp.edu</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Department of Psychology, University of North Carolina at Pembroke</wicri:regionArea>
<wicri:noRegion>University of North Carolina at Pembroke</wicri:noRegion>
</affiliation>
</author>
</analytic>
<series><title level="j">Journal of experimental psychology. Human perception and performance</title>
<idno type="eISSN">1939-1277</idno>
<imprint><date when="2010" type="published">2010</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Adolescent</term>
<term>Adult</term>
<term>Female</term>
<term>Form Perception</term>
<term>Humans</term>
<term>Judgment</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Reaction Time</term>
<term>Size Perception</term>
<term>Touch Perception</term>
<term>Young Adult</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Adolescent</term>
<term>Adult</term>
<term>Female</term>
<term>Form Perception</term>
<term>Humans</term>
<term>Judgment</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Reaction Time</term>
<term>Size Perception</term>
<term>Touch Perception</term>
<term>Young Adult</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">Many studies invoke moment of inertia (Iii) as necessary and sufficient information to perceive cylinder length via wielding, yet some assert that Iii is neither necessary (weight, m, or static moment, M, are sufficient) nor sufficient for length judgments (m or M is necessary). Mathematical expressions for Iii not involving m or M imply length, so Iii could be sufficient for cylinder length judgments. In 5 experiments (N = 113), only longitudinal Iii (the smallest principal value) informed cylinder length estimates in a novel task, rolling. Experiment 1 yielded reliable length judgments. Varying diameter supported length scaling (Experiment 2); similar length estimates occurred with both rolling and wielding (Experiment 3); feedback improved rolling length judgments to levels commensurate with wielding (Experiment 4); and length judgments shifted predictably with added mass (Experiment 5). Contrary to proposals in the literature, Iii is sufficient information for cylinder length judgments, absent m or M information, even when Iii is of minimal magnitude and the task quite novel.</div>
</front>
</TEI>
<affiliations><list><country><li>États-Unis</li>
</country>
</list>
<tree><country name="États-Unis"><noRegion><name sortKey="Cabe, Patrick A" sort="Cabe, Patrick A" uniqKey="Cabe P" first="Patrick A" last="Cabe">Patrick A. Cabe</name>
</noRegion>
</country>
</tree>
</affiliations>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 003529 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 003529 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Ticri/CIDE |area= HapticV1 |flux= Main |étape= Exploration |type= RBID |clé= pubmed:20364925 |texte= Sufficiency of longitudinal moment of inertia for haptic cylinder length judgments. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Exploration/RBID.i -Sk "pubmed:20364925" \ | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd \ | NlmPubMed2Wicri -a HapticV1
![]() | This area was generated with Dilib version V0.6.23. | ![]() |