Sufficiency of longitudinal moment of inertia for haptic cylinder length judgments.
Identifieur interne : 001115 ( PubMed/Corpus ); précédent : 001114; suivant : 001116Sufficiency of longitudinal moment of inertia for haptic cylinder length judgments.
Auteurs : Patrick A. CabeSource :
- Journal of experimental psychology. Human perception and performance [ 1939-1277 ] ; 2010.
English descriptors
- KwdEn :
- MESH :
Abstract
Many studies invoke moment of inertia (Iii) as necessary and sufficient information to perceive cylinder length via wielding, yet some assert that Iii is neither necessary (weight, m, or static moment, M, are sufficient) nor sufficient for length judgments (m or M is necessary). Mathematical expressions for Iii not involving m or M imply length, so Iii could be sufficient for cylinder length judgments. In 5 experiments (N = 113), only longitudinal Iii (the smallest principal value) informed cylinder length estimates in a novel task, rolling. Experiment 1 yielded reliable length judgments. Varying diameter supported length scaling (Experiment 2); similar length estimates occurred with both rolling and wielding (Experiment 3); feedback improved rolling length judgments to levels commensurate with wielding (Experiment 4); and length judgments shifted predictably with added mass (Experiment 5). Contrary to proposals in the literature, Iii is sufficient information for cylinder length judgments, absent m or M information, even when Iii is of minimal magnitude and the task quite novel.
DOI: 10.1037/a0018395
PubMed: 20364925
Links to Exploration step
pubmed:20364925Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">Sufficiency of longitudinal moment of inertia for haptic cylinder length judgments.</title>
<author><name sortKey="Cabe, Patrick A" sort="Cabe, Patrick A" uniqKey="Cabe P" first="Patrick A" last="Cabe">Patrick A. Cabe</name>
<affiliation><nlm:affiliation>Department of Psychology, University of North Carolina at Pembroke, USA. patrick.cabe@uncp.edu</nlm:affiliation>
</affiliation>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="2010">2010</date>
<idno type="doi">10.1037/a0018395</idno>
<idno type="RBID">pubmed:20364925</idno>
<idno type="pmid">20364925</idno>
<idno type="wicri:Area/PubMed/Corpus">001115</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">Sufficiency of longitudinal moment of inertia for haptic cylinder length judgments.</title>
<author><name sortKey="Cabe, Patrick A" sort="Cabe, Patrick A" uniqKey="Cabe P" first="Patrick A" last="Cabe">Patrick A. Cabe</name>
<affiliation><nlm:affiliation>Department of Psychology, University of North Carolina at Pembroke, USA. patrick.cabe@uncp.edu</nlm:affiliation>
</affiliation>
</author>
</analytic>
<series><title level="j">Journal of experimental psychology. Human perception and performance</title>
<idno type="eISSN">1939-1277</idno>
<imprint><date when="2010" type="published">2010</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Adolescent</term>
<term>Adult</term>
<term>Female</term>
<term>Form Perception</term>
<term>Humans</term>
<term>Judgment</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Reaction Time</term>
<term>Size Perception</term>
<term>Touch Perception</term>
<term>Young Adult</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Adolescent</term>
<term>Adult</term>
<term>Female</term>
<term>Form Perception</term>
<term>Humans</term>
<term>Judgment</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Reaction Time</term>
<term>Size Perception</term>
<term>Touch Perception</term>
<term>Young Adult</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">Many studies invoke moment of inertia (Iii) as necessary and sufficient information to perceive cylinder length via wielding, yet some assert that Iii is neither necessary (weight, m, or static moment, M, are sufficient) nor sufficient for length judgments (m or M is necessary). Mathematical expressions for Iii not involving m or M imply length, so Iii could be sufficient for cylinder length judgments. In 5 experiments (N = 113), only longitudinal Iii (the smallest principal value) informed cylinder length estimates in a novel task, rolling. Experiment 1 yielded reliable length judgments. Varying diameter supported length scaling (Experiment 2); similar length estimates occurred with both rolling and wielding (Experiment 3); feedback improved rolling length judgments to levels commensurate with wielding (Experiment 4); and length judgments shifted predictably with added mass (Experiment 5). Contrary to proposals in the literature, Iii is sufficient information for cylinder length judgments, absent m or M information, even when Iii is of minimal magnitude and the task quite novel.</div>
</front>
</TEI>
<pubmed><MedlineCitation Owner="NLM" Status="MEDLINE"><PMID Version="1">20364925</PMID>
<DateCreated><Year>2010</Year>
<Month>04</Month>
<Day>06</Day>
</DateCreated>
<DateCompleted><Year>2010</Year>
<Month>06</Month>
<Day>28</Day>
</DateCompleted>
<Article PubModel="Print"><Journal><ISSN IssnType="Electronic">1939-1277</ISSN>
<JournalIssue CitedMedium="Internet"><Volume>36</Volume>
<Issue>2</Issue>
<PubDate><Year>2010</Year>
<Month>Apr</Month>
</PubDate>
</JournalIssue>
<Title>Journal of experimental psychology. Human perception and performance</Title>
<ISOAbbreviation>J Exp Psychol Hum Percept Perform</ISOAbbreviation>
</Journal>
<ArticleTitle>Sufficiency of longitudinal moment of inertia for haptic cylinder length judgments.</ArticleTitle>
<Pagination><MedlinePgn>373-94</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1037/a0018395</ELocationID>
<Abstract><AbstractText>Many studies invoke moment of inertia (Iii) as necessary and sufficient information to perceive cylinder length via wielding, yet some assert that Iii is neither necessary (weight, m, or static moment, M, are sufficient) nor sufficient for length judgments (m or M is necessary). Mathematical expressions for Iii not involving m or M imply length, so Iii could be sufficient for cylinder length judgments. In 5 experiments (N = 113), only longitudinal Iii (the smallest principal value) informed cylinder length estimates in a novel task, rolling. Experiment 1 yielded reliable length judgments. Varying diameter supported length scaling (Experiment 2); similar length estimates occurred with both rolling and wielding (Experiment 3); feedback improved rolling length judgments to levels commensurate with wielding (Experiment 4); and length judgments shifted predictably with added mass (Experiment 5). Contrary to proposals in the literature, Iii is sufficient information for cylinder length judgments, absent m or M information, even when Iii is of minimal magnitude and the task quite novel.</AbstractText>
<CopyrightInformation>Copyright 2010 APA, all rights reserved.</CopyrightInformation>
</Abstract>
<AuthorList CompleteYN="Y"><Author ValidYN="Y"><LastName>Cabe</LastName>
<ForeName>Patrick A</ForeName>
<Initials>PA</Initials>
<AffiliationInfo><Affiliation>Department of Psychology, University of North Carolina at Pembroke, USA. patrick.cabe@uncp.edu</Affiliation>
</AffiliationInfo>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList><PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo><Country>United States</Country>
<MedlineTA>J Exp Psychol Hum Percept Perform</MedlineTA>
<NlmUniqueID>7502589</NlmUniqueID>
<ISSNLinking>0096-1523</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList><MeshHeading><DescriptorName MajorTopicYN="N" UI="D000293">Adolescent</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D000328">Adult</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D005260">Female</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D005556">Form Perception</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="Y" UI="D007600">Judgment</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D008297">Male</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D008875">Middle Aged</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D011930">Reaction Time</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="Y" UI="D012858">Size Perception</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="Y" UI="D055698">Touch Perception</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D055815">Young Adult</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData><History><PubMedPubDate PubStatus="entrez"><Year>2010</Year>
<Month>4</Month>
<Day>7</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed"><Year>2010</Year>
<Month>4</Month>
<Day>7</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline"><Year>2010</Year>
<Month>6</Month>
<Day>29</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList><ArticleId IdType="pii">2010-06263-009</ArticleId>
<ArticleId IdType="doi">10.1037/a0018395</ArticleId>
<ArticleId IdType="pubmed">20364925</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001115 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 001115 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Ticri/CIDE |area= HapticV1 |flux= PubMed |étape= Corpus |type= RBID |clé= pubmed:20364925 |texte= Sufficiency of longitudinal moment of inertia for haptic cylinder length judgments. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i -Sk "pubmed:20364925" \ | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd \ | NlmPubMed2Wicri -a HapticV1
![]() | This area was generated with Dilib version V0.6.23. | ![]() |