Lower stimulation frequency can enhance tolerability and efficacy of pallidal deep brain stimulation for dystonia
Identifieur interne : 002D62 ( Main/Exploration ); précédent : 002D61; suivant : 002D63Lower stimulation frequency can enhance tolerability and efficacy of pallidal deep brain stimulation for dystonia
Auteurs : Ron L. Alterman [États-Unis] ; Jay L. Shils [États-Unis] ; Joan Miravite [États-Unis] ; Michele Tagliati [États-Unis]Source :
- Movement Disorders [ 0885-3185 ] ; 2007-02-15.
Descripteurs français
- Pascal (Inist)
English descriptors
- KwdEn :
- Deep Brain Stimulation (adverse effects), Deep Brain Stimulation (methods), Deep brain stimulation, Dose-Response Relationship, Radiation, Dystonia, Dystonia (pathology), Follow-Up Studies, Globus Pallidus (radiation effects), Humans, Magnetic Resonance Imaging, Male, Middle Aged, Nervous system diseases, deep brain stimulation, dystonia, frequency, globus pallidus.
- MESH :
- adverse effects : Deep Brain Stimulation.
- methods : Deep Brain Stimulation.
- pathology : Dystonia.
- radiation effects : Globus Pallidus.
- Dose-Response Relationship, Radiation, Follow-Up Studies, Humans, Magnetic Resonance Imaging, Male, Middle Aged.
Abstract
We report the case of a patient with medically refractory primary dystonia who was treated with bilateral pallidal deep brain stimulation. Stimulation at 130 Hz or higher, by means of the more ventral contacts generated capsular side effects, which made their use impractical. Consequently, the patient was treated for 9 months at 130 to 185 Hz, by means of the more dorsal contacts, achieving modest results. By reducing the stimulation frequency to 80 Hz, we were able to activate the ventral contacts without inducing side effects. Within days, the patient experienced a dramatic improvement in function that has persisted for 1 year. A further reduction in stimulation frequency to 60 Hz resulted in a worsening of his symptoms. We conclude that chronic stimulation at frequencies of <100 Hz may be efficacious in dystonia and may enhance the tolerability of stimulation by means of contacts that are positioned posteroventrally within the internal globus pallidus, nearer the internal capsule. © 2006 Movement Disorder Society
Url:
DOI: 10.1002/mds.21274
Affiliations:
Links toward previous steps (curation, corpus...)
- to stream Istex, to step Corpus: 003137
- to stream Istex, to step Curation: 003137
- to stream Istex, to step Checkpoint: 001870
- to stream PubMed, to step Corpus: 002928
- to stream PubMed, to step Curation: 002928
- to stream PubMed, to step Checkpoint: 002734
- to stream Ncbi, to step Merge: 001A11
- to stream Ncbi, to step Curation: 001A11
- to stream Ncbi, to step Checkpoint: 001A11
- to stream Main, to step Merge: 003C84
- to stream PascalFrancis, to step Corpus: 001778
- to stream PascalFrancis, to step Curation: 001543
- to stream PascalFrancis, to step Checkpoint: 001605
- to stream Main, to step Merge: 004195
- to stream Main, to step Curation: 002D62
Le document en format XML
<record><TEI wicri:istexFullTextTei="biblStruct"><teiHeader><fileDesc><titleStmt><title xml:lang="en">Lower stimulation frequency can enhance tolerability and efficacy of pallidal deep brain stimulation for dystonia</title>
<author><name sortKey="Alterman, Ron L" sort="Alterman, Ron L" uniqKey="Alterman R" first="Ron L." last="Alterman">Ron L. Alterman</name>
</author>
<author><name sortKey="Shils, Jay L" sort="Shils, Jay L" uniqKey="Shils J" first="Jay L." last="Shils">Jay L. Shils</name>
</author>
<author><name sortKey="Miravite, Joan" sort="Miravite, Joan" uniqKey="Miravite J" first="Joan" last="Miravite">Joan Miravite</name>
</author>
<author><name sortKey="Tagliati, Michele" sort="Tagliati, Michele" uniqKey="Tagliati M" first="Michele" last="Tagliati">Michele Tagliati</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:BE5554AD1B3E605F16E2013C4F2AD8C762B70C03</idno>
<date when="2007" year="2007">2007</date>
<idno type="doi">10.1002/mds.21274</idno>
<idno type="url">https://api.istex.fr/document/BE5554AD1B3E605F16E2013C4F2AD8C762B70C03/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">003137</idno>
<idno type="wicri:Area/Istex/Curation">003137</idno>
<idno type="wicri:Area/Istex/Checkpoint">001870</idno>
<idno type="wicri:doubleKey">0885-3185:2007:Alterman R:lower:stimulation:frequency</idno>
<idno type="wicri:source">PubMed</idno>
<idno type="RBID">pubmed:17216642</idno>
<idno type="wicri:Area/PubMed/Corpus">002928</idno>
<idno type="wicri:Area/PubMed/Curation">002928</idno>
<idno type="wicri:Area/PubMed/Checkpoint">002734</idno>
<idno type="wicri:Area/Ncbi/Merge">001A11</idno>
<idno type="wicri:Area/Ncbi/Curation">001A11</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">001A11</idno>
<idno type="wicri:doubleKey">0885-3185:2007:Alterman R:lower:stimulation:frequency</idno>
<idno type="wicri:Area/Main/Merge">003C84</idno>
<idno type="wicri:source">INIST</idno>
<idno type="RBID">Pascal:07-0181695</idno>
<idno type="wicri:Area/PascalFrancis/Corpus">001778</idno>
<idno type="wicri:Area/PascalFrancis/Curation">001543</idno>
<idno type="wicri:Area/PascalFrancis/Checkpoint">001605</idno>
<idno type="wicri:doubleKey">0885-3185:2007:Alterman R:lower:stimulation:frequency</idno>
<idno type="wicri:Area/Main/Merge">004195</idno>
<idno type="wicri:Area/Main/Curation">002D62</idno>
<idno type="wicri:Area/Main/Exploration">002D62</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title level="a" type="main" xml:lang="en">Lower stimulation frequency can enhance tolerability and efficacy of pallidal deep brain stimulation for dystonia</title>
<author><name sortKey="Alterman, Ron L" sort="Alterman, Ron L" uniqKey="Alterman R" first="Ron L." last="Alterman">Ron L. Alterman</name>
<affiliation wicri:level="2"><country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Mount Sinai School of Medicine, New York, New York</wicri:regionArea>
<placeName><region type="state">État de New York</region>
</placeName>
</affiliation>
</author>
<author><name sortKey="Shils, Jay L" sort="Shils, Jay L" uniqKey="Shils J" first="Jay L." last="Shils">Jay L. Shils</name>
<affiliation wicri:level="2"><country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Lahey Clinic, Burlington, Massachusetts</wicri:regionArea>
<placeName><region type="state">Massachusetts</region>
</placeName>
</affiliation>
</author>
<author><name sortKey="Miravite, Joan" sort="Miravite, Joan" uniqKey="Miravite J" first="Joan" last="Miravite">Joan Miravite</name>
<affiliation wicri:level="2"><country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Mount Sinai School of Medicine, New York, New York</wicri:regionArea>
<placeName><region type="state">État de New York</region>
</placeName>
</affiliation>
</author>
<author><name sortKey="Tagliati, Michele" sort="Tagliati, Michele" uniqKey="Tagliati M" first="Michele" last="Tagliati">Michele Tagliati</name>
<affiliation wicri:level="2"><country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Mount Sinai School of Medicine, New York, New York</wicri:regionArea>
<placeName><region type="state">État de New York</region>
</placeName>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series><title level="j">Movement Disorders</title>
<title level="j" type="sub">Official Journal of the Movement Disorder Society</title>
<title level="j" type="abbrev">Mov. Disord.</title>
<idno type="ISSN">0885-3185</idno>
<idno type="eISSN">1531-8257</idno>
<imprint><publisher>Wiley Subscription Services, Inc., A Wiley Company</publisher>
<pubPlace>Hoboken</pubPlace>
<date type="published" when="2007-02-15">2007-02-15</date>
<biblScope unit="vol">22</biblScope>
<biblScope unit="issue">3</biblScope>
<biblScope unit="page" from="366">366</biblScope>
<biblScope unit="page" to="368">368</biblScope>
</imprint>
<idno type="ISSN">0885-3185</idno>
</series>
<idno type="istex">BE5554AD1B3E605F16E2013C4F2AD8C762B70C03</idno>
<idno type="DOI">10.1002/mds.21274</idno>
<idno type="ArticleID">MDS21274</idno>
</biblStruct>
</sourceDesc>
<seriesStmt><idno type="ISSN">0885-3185</idno>
</seriesStmt>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Deep Brain Stimulation (adverse effects)</term>
<term>Deep Brain Stimulation (methods)</term>
<term>Deep brain stimulation</term>
<term>Dose-Response Relationship, Radiation</term>
<term>Dystonia</term>
<term>Dystonia (pathology)</term>
<term>Follow-Up Studies</term>
<term>Globus Pallidus (radiation effects)</term>
<term>Humans</term>
<term>Magnetic Resonance Imaging</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Nervous system diseases</term>
<term>deep brain stimulation</term>
<term>dystonia</term>
<term>frequency</term>
<term>globus pallidus</term>
</keywords>
<keywords scheme="MESH" qualifier="adverse effects" xml:lang="en"><term>Deep Brain Stimulation</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en"><term>Deep Brain Stimulation</term>
</keywords>
<keywords scheme="MESH" qualifier="pathology" xml:lang="en"><term>Dystonia</term>
</keywords>
<keywords scheme="MESH" qualifier="radiation effects" xml:lang="en"><term>Globus Pallidus</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Dose-Response Relationship, Radiation</term>
<term>Follow-Up Studies</term>
<term>Humans</term>
<term>Magnetic Resonance Imaging</term>
<term>Male</term>
<term>Middle Aged</term>
</keywords>
<keywords scheme="Pascal" xml:lang="fr"><term>Dystonie</term>
<term>Stimulation cérébrale profonde</term>
<term>Système nerveux pathologie</term>
</keywords>
</textClass>
<langUsage><language ident="en">en</language>
</langUsage>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">We report the case of a patient with medically refractory primary dystonia who was treated with bilateral pallidal deep brain stimulation. Stimulation at 130 Hz or higher, by means of the more ventral contacts generated capsular side effects, which made their use impractical. Consequently, the patient was treated for 9 months at 130 to 185 Hz, by means of the more dorsal contacts, achieving modest results. By reducing the stimulation frequency to 80 Hz, we were able to activate the ventral contacts without inducing side effects. Within days, the patient experienced a dramatic improvement in function that has persisted for 1 year. A further reduction in stimulation frequency to 60 Hz resulted in a worsening of his symptoms. We conclude that chronic stimulation at frequencies of <100 Hz may be efficacious in dystonia and may enhance the tolerability of stimulation by means of contacts that are positioned posteroventrally within the internal globus pallidus, nearer the internal capsule. © 2006 Movement Disorder Society</div>
</front>
</TEI>
<affiliations><list><country><li>États-Unis</li>
</country>
<region><li>Massachusetts</li>
<li>État de New York</li>
</region>
</list>
<tree><country name="États-Unis"><region name="État de New York"><name sortKey="Alterman, Ron L" sort="Alterman, Ron L" uniqKey="Alterman R" first="Ron L." last="Alterman">Ron L. Alterman</name>
</region>
<name sortKey="Miravite, Joan" sort="Miravite, Joan" uniqKey="Miravite J" first="Joan" last="Miravite">Joan Miravite</name>
<name sortKey="Shils, Jay L" sort="Shils, Jay L" uniqKey="Shils J" first="Jay L." last="Shils">Jay L. Shils</name>
<name sortKey="Tagliati, Michele" sort="Tagliati, Michele" uniqKey="Tagliati M" first="Michele" last="Tagliati">Michele Tagliati</name>
</country>
</tree>
</affiliations>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/MovDisordV3/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 002D62 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 002D62 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Santé |area= MovDisordV3 |flux= Main |étape= Exploration |type= RBID |clé= ISTEX:BE5554AD1B3E605F16E2013C4F2AD8C762B70C03 |texte= Lower stimulation frequency can enhance tolerability and efficacy of pallidal deep brain stimulation for dystonia }}
This area was generated with Dilib version V0.6.23. |