Assessment of breast cancer-related lymphedema: a comparison of moisture meter and spot bioimpedance measurement.

Identifieur interne : 001055 ( PubMed/Corpus ); précédent : 001054; suivant : 001056

Assessment of breast cancer-related lymphedema: a comparison of moisture meter and spot bioimpedance measurement.

Auteurs : Sharon Anne Czerniec ; Leigh C. Ward ; Sharon L. Kilbreath

Source :

RBID : pubmed:25667950

English descriptors

Abstract

Tissue dielectric constant (TDC) and spot bioimpedance measurement (BIA) have a role in the assessment of tissue composition changes in breast cancer-related lymphedema (BCRL). Our aims were to determine whether TDC and spot BIA measures could detect inter-limb differences in BCRL, explore the relationship between methods, and establish the intra-rater reliability and technical error of measurement for TDC.

DOI: 10.1089/lrb.2014.0032
PubMed: 25667950

Links to Exploration step

pubmed:25667950

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Assessment of breast cancer-related lymphedema: a comparison of moisture meter and spot bioimpedance measurement.</title>
<author>
<name sortKey="Czerniec, Sharon Anne" sort="Czerniec, Sharon Anne" uniqKey="Czerniec S" first="Sharon Anne" last="Czerniec">Sharon Anne Czerniec</name>
<affiliation>
<nlm:affiliation>1 Faculty of Health Sciences, University of Sydney , Sydney, Australia .</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Ward, Leigh C" sort="Ward, Leigh C" uniqKey="Ward L" first="Leigh C" last="Ward">Leigh C. Ward</name>
</author>
<author>
<name sortKey="Kilbreath, Sharon L" sort="Kilbreath, Sharon L" uniqKey="Kilbreath S" first="Sharon L" last="Kilbreath">Sharon L. Kilbreath</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2015">2015</date>
<idno type="RBID">pubmed:25667950</idno>
<idno type="pmid">25667950</idno>
<idno type="doi">10.1089/lrb.2014.0032</idno>
<idno type="wicri:Area/PubMed/Corpus">001055</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">001055</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Assessment of breast cancer-related lymphedema: a comparison of moisture meter and spot bioimpedance measurement.</title>
<author>
<name sortKey="Czerniec, Sharon Anne" sort="Czerniec, Sharon Anne" uniqKey="Czerniec S" first="Sharon Anne" last="Czerniec">Sharon Anne Czerniec</name>
<affiliation>
<nlm:affiliation>1 Faculty of Health Sciences, University of Sydney , Sydney, Australia .</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Ward, Leigh C" sort="Ward, Leigh C" uniqKey="Ward L" first="Leigh C" last="Ward">Leigh C. Ward</name>
</author>
<author>
<name sortKey="Kilbreath, Sharon L" sort="Kilbreath, Sharon L" uniqKey="Kilbreath S" first="Sharon L" last="Kilbreath">Sharon L. Kilbreath</name>
</author>
</analytic>
<series>
<title level="j">Lymphatic research and biology</title>
<idno type="eISSN">1557-8585</idno>
<imprint>
<date when="2015" type="published">2015</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Adult</term>
<term>Aged</term>
<term>Arm (pathology)</term>
<term>Body Weights and Measures</term>
<term>Breast Neoplasms (complications)</term>
<term>Breast Neoplasms (surgery)</term>
<term>Electric Impedance</term>
<term>Female</term>
<term>Humans</term>
<term>Lymphedema (diagnosis)</term>
<term>Lymphedema (etiology)</term>
<term>Middle Aged</term>
<term>Young Adult</term>
</keywords>
<keywords scheme="MESH" qualifier="complications" xml:lang="en">
<term>Breast Neoplasms</term>
</keywords>
<keywords scheme="MESH" qualifier="diagnosis" xml:lang="en">
<term>Lymphedema</term>
</keywords>
<keywords scheme="MESH" qualifier="etiology" xml:lang="en">
<term>Lymphedema</term>
</keywords>
<keywords scheme="MESH" qualifier="pathology" xml:lang="en">
<term>Arm</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en">
<term>Breast Neoplasms</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Adult</term>
<term>Aged</term>
<term>Body Weights and Measures</term>
<term>Electric Impedance</term>
<term>Female</term>
<term>Humans</term>
<term>Middle Aged</term>
<term>Young Adult</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Tissue dielectric constant (TDC) and spot bioimpedance measurement (BIA) have a role in the assessment of tissue composition changes in breast cancer-related lymphedema (BCRL). Our aims were to determine whether TDC and spot BIA measures could detect inter-limb differences in BCRL, explore the relationship between methods, and establish the intra-rater reliability and technical error of measurement for TDC.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Status="MEDLINE" Owner="NLM">
<PMID Version="1">25667950</PMID>
<DateCreated>
<Year>2015</Year>
<Month>03</Month>
<Day>15</Day>
</DateCreated>
<DateCompleted>
<Year>2015</Year>
<Month>12</Month>
<Day>01</Day>
</DateCompleted>
<DateRevised>
<Year>2015</Year>
<Month>03</Month>
<Day>15</Day>
</DateRevised>
<Article PubModel="Print-Electronic">
<Journal>
<ISSN IssnType="Electronic">1557-8585</ISSN>
<JournalIssue CitedMedium="Internet">
<Volume>13</Volume>
<Issue>1</Issue>
<PubDate>
<Year>2015</Year>
<Month>Mar</Month>
</PubDate>
</JournalIssue>
<Title>Lymphatic research and biology</Title>
<ISOAbbreviation>Lymphat Res Biol</ISOAbbreviation>
</Journal>
<ArticleTitle>Assessment of breast cancer-related lymphedema: a comparison of moisture meter and spot bioimpedance measurement.</ArticleTitle>
<Pagination>
<MedlinePgn>10-9</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1089/lrb.2014.0032</ELocationID>
<Abstract>
<AbstractText Label="BACKGROUND" NlmCategory="BACKGROUND">Tissue dielectric constant (TDC) and spot bioimpedance measurement (BIA) have a role in the assessment of tissue composition changes in breast cancer-related lymphedema (BCRL). Our aims were to determine whether TDC and spot BIA measures could detect inter-limb differences in BCRL, explore the relationship between methods, and establish the intra-rater reliability and technical error of measurement for TDC.</AbstractText>
<AbstractText Label="METHODS AND RESULTS" NlmCategory="RESULTS">Women with (n=20) and without (n=4) unilateral BCRL participated. Circumference, TDC, and spot BIA measures were completed on the most affected region of the arm for BCRL participants and at a standardized forearm point in women without lymphedema. All measures were compared to measurements from an identical location on the contralateral arm. The affected arm differed significantly to the unaffected arm of women with BCRL for TDC and spot BIA measures. The median (IQR) differences were: extra-small probe 5.75 (3.10-8.21), small probe 3.50 (1.16-6.89), medium probe 5.08 (0.88-10.91), and for spot BIA measurement (-35.20 Ω; -59.75 to -14.85 Ω). The small and medium TDC probe measures were moderately correlated to spot bioimpedance measurements (r=-0.54 and r=-0.43, respectively). Intra-rater reliability coefficients (ICC2,1) of TDC measures ranged from 0.50 (95% CI: 0.12-0.75) to 0.92 (0.82-0.96). TDC technical error of measurement for women with lymphedema varied from 10.5% to 13.3%.</AbstractText>
<AbstractText Label="CONCLUSIONS" NlmCategory="CONCLUSIONS">Both TDC and spot bioimpedance may have a role in clinical assessment of tissue compositional change in BCRL. Their relationship with tissue composition, assessed by imaging, is now required.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Czerniec</LastName>
<ForeName>Sharon Anne</ForeName>
<Initials>SA</Initials>
<AffiliationInfo>
<Affiliation>1 Faculty of Health Sciences, University of Sydney , Sydney, Australia .</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Ward</LastName>
<ForeName>Leigh C</ForeName>
<Initials>LC</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Kilbreath</LastName>
<ForeName>Sharon L</ForeName>
<Initials>SL</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
<PublicationType UI="D013485">Research Support, Non-U.S. Gov't</PublicationType>
</PublicationTypeList>
<ArticleDate DateType="Electronic">
<Year>2015</Year>
<Month>02</Month>
<Day>10</Day>
</ArticleDate>
</Article>
<MedlineJournalInfo>
<Country>United States</Country>
<MedlineTA>Lymphat Res Biol</MedlineTA>
<NlmUniqueID>101163587</NlmUniqueID>
<ISSNLinking>1539-6851</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName UI="D000328" MajorTopicYN="N">Adult</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D000368" MajorTopicYN="N">Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D001132" MajorTopicYN="N">Arm</DescriptorName>
<QualifierName UI="Q000473" MajorTopicYN="N">pathology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D001837" MajorTopicYN="N">Body Weights and Measures</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D001943" MajorTopicYN="N">Breast Neoplasms</DescriptorName>
<QualifierName UI="Q000150" MajorTopicYN="Y">complications</QualifierName>
<QualifierName UI="Q000601" MajorTopicYN="N">surgery</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D017097" MajorTopicYN="N">Electric Impedance</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D005260" MajorTopicYN="N">Female</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008209" MajorTopicYN="N">Lymphedema</DescriptorName>
<QualifierName UI="Q000175" MajorTopicYN="Y">diagnosis</QualifierName>
<QualifierName UI="Q000209" MajorTopicYN="Y">etiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008875" MajorTopicYN="N">Middle Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D055815" MajorTopicYN="N">Young Adult</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="entrez">
<Year>2015</Year>
<Month>2</Month>
<Day>11</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2015</Year>
<Month>2</Month>
<Day>11</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2015</Year>
<Month>12</Month>
<Day>15</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">25667950</ArticleId>
<ArticleId IdType="doi">10.1089/lrb.2014.0032</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Sante/explor/LymphedemaV1/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001055 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 001055 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Sante
   |area=    LymphedemaV1
   |flux=    PubMed
   |étape=   Corpus
   |type=    RBID
   |clé=     pubmed:25667950
   |texte=   Assessment of breast cancer-related lymphedema: a comparison of moisture meter and spot bioimpedance measurement.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i   -Sk "pubmed:25667950" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a LymphedemaV1 

Wicri

This area was generated with Dilib version V0.6.31.
Data generation: Sat Nov 4 17:40:35 2017. Site generation: Tue Feb 13 16:42:16 2024