Inter-Changeability of Impedance Devices for Lymphedema Assessment.

Identifieur interne : 000F49 ( Main/Exploration ); précédent : 000F48; suivant : 000F50

Inter-Changeability of Impedance Devices for Lymphedema Assessment.

Auteurs : Malou Van Zanten [Australie] ; Neil Piller [Australie] ; Leigh C. Ward [Australie]

Source :

RBID : pubmed:26574711

Abstract

Impedance technology is a popular technique for the early detection of lymphedema. The preferred approach is to use bioimpedance spectroscopy (BIS), with measurements being made with the subject lying supine, although attempts have been made to use single or multiple frequency impedance measurements obtained while the subject is standing. The aim of the present study was to determine the equivalence of these different approaches. Impedance measurements of the individual limbs of 37 healthy individuals were determined using both a stand-on, multi-frequency impedance device and a supine impedance spectroscopy instrument. Significant differences were found between the instruments in both absolute impedance values and, importantly, inter-limb impedance ratios. Since impedance ratios in healthy individuals provide the reference standard for detection of lymphedema, these data indicate that the methods are not interchangeable. Consideration of the errors associated with each method indicates that the BIS remains the preferred method for lymphedema detection.

DOI: 10.1089/lrb.2015.0026
PubMed: 26574711


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Inter-Changeability of Impedance Devices for Lymphedema Assessment.</title>
<author>
<name sortKey="Van Zanten, Malou" sort="Van Zanten, Malou" uniqKey="Van Zanten M" first="Malou" last="Van Zanten">Malou Van Zanten</name>
<affiliation wicri:level="1">
<nlm:affiliation>1 Lymphoedema Research Unit, Department of Surgery, School of Medicine, Flinders University , South Australia, Australia .</nlm:affiliation>
<country xml:lang="fr">Australie</country>
<wicri:regionArea>1 Lymphoedema Research Unit, Department of Surgery, School of Medicine, Flinders University , South Australia</wicri:regionArea>
<wicri:noRegion>South Australia</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Piller, Neil" sort="Piller, Neil" uniqKey="Piller N" first="Neil" last="Piller">Neil Piller</name>
<affiliation wicri:level="1">
<nlm:affiliation>1 Lymphoedema Research Unit, Department of Surgery, School of Medicine, Flinders University , South Australia, Australia .</nlm:affiliation>
<country xml:lang="fr">Australie</country>
<wicri:regionArea>1 Lymphoedema Research Unit, Department of Surgery, School of Medicine, Flinders University , South Australia</wicri:regionArea>
<wicri:noRegion>South Australia</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Ward, Leigh C" sort="Ward, Leigh C" uniqKey="Ward L" first="Leigh C" last="Ward">Leigh C. Ward</name>
<affiliation wicri:level="1">
<nlm:affiliation>2 School Chemistry and Molecular Biosciences, The University of Queensland , Queensland, Australia .</nlm:affiliation>
<country xml:lang="fr">Australie</country>
<wicri:regionArea>2 School Chemistry and Molecular Biosciences, The University of Queensland , Queensland</wicri:regionArea>
<wicri:noRegion>Queensland</wicri:noRegion>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2016">2016</date>
<idno type="RBID">pubmed:26574711</idno>
<idno type="pmid">26574711</idno>
<idno type="doi">10.1089/lrb.2015.0026</idno>
<idno type="wicri:Area/PubMed/Corpus">000B39</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">000B39</idno>
<idno type="wicri:Area/PubMed/Curation">000B39</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">000B39</idno>
<idno type="wicri:Area/PubMed/Checkpoint">000B39</idno>
<idno type="wicri:explorRef" wicri:stream="Checkpoint" wicri:step="PubMed">000B39</idno>
<idno type="wicri:Area/Ncbi/Merge">007B34</idno>
<idno type="wicri:Area/Ncbi/Curation">007B34</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">007B34</idno>
<idno type="wicri:Area/Main/Merge">000F51</idno>
<idno type="wicri:Area/Main/Curation">000F49</idno>
<idno type="wicri:Area/Main/Exploration">000F49</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Inter-Changeability of Impedance Devices for Lymphedema Assessment.</title>
<author>
<name sortKey="Van Zanten, Malou" sort="Van Zanten, Malou" uniqKey="Van Zanten M" first="Malou" last="Van Zanten">Malou Van Zanten</name>
<affiliation wicri:level="1">
<nlm:affiliation>1 Lymphoedema Research Unit, Department of Surgery, School of Medicine, Flinders University , South Australia, Australia .</nlm:affiliation>
<country xml:lang="fr">Australie</country>
<wicri:regionArea>1 Lymphoedema Research Unit, Department of Surgery, School of Medicine, Flinders University , South Australia</wicri:regionArea>
<wicri:noRegion>South Australia</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Piller, Neil" sort="Piller, Neil" uniqKey="Piller N" first="Neil" last="Piller">Neil Piller</name>
<affiliation wicri:level="1">
<nlm:affiliation>1 Lymphoedema Research Unit, Department of Surgery, School of Medicine, Flinders University , South Australia, Australia .</nlm:affiliation>
<country xml:lang="fr">Australie</country>
<wicri:regionArea>1 Lymphoedema Research Unit, Department of Surgery, School of Medicine, Flinders University , South Australia</wicri:regionArea>
<wicri:noRegion>South Australia</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Ward, Leigh C" sort="Ward, Leigh C" uniqKey="Ward L" first="Leigh C" last="Ward">Leigh C. Ward</name>
<affiliation wicri:level="1">
<nlm:affiliation>2 School Chemistry and Molecular Biosciences, The University of Queensland , Queensland, Australia .</nlm:affiliation>
<country xml:lang="fr">Australie</country>
<wicri:regionArea>2 School Chemistry and Molecular Biosciences, The University of Queensland , Queensland</wicri:regionArea>
<wicri:noRegion>Queensland</wicri:noRegion>
</affiliation>
</author>
</analytic>
<series>
<title level="j">Lymphatic research and biology</title>
<idno type="eISSN">1557-8585</idno>
<imprint>
<date when="2016" type="published">2016</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Impedance technology is a popular technique for the early detection of lymphedema. The preferred approach is to use bioimpedance spectroscopy (BIS), with measurements being made with the subject lying supine, although attempts have been made to use single or multiple frequency impedance measurements obtained while the subject is standing. The aim of the present study was to determine the equivalence of these different approaches. Impedance measurements of the individual limbs of 37 healthy individuals were determined using both a stand-on, multi-frequency impedance device and a supine impedance spectroscopy instrument. Significant differences were found between the instruments in both absolute impedance values and, importantly, inter-limb impedance ratios. Since impedance ratios in healthy individuals provide the reference standard for detection of lymphedema, these data indicate that the methods are not interchangeable. Consideration of the errors associated with each method indicates that the BIS remains the preferred method for lymphedema detection.</div>
</front>
</TEI>
<affiliations>
<list>
<country>
<li>Australie</li>
</country>
</list>
<tree>
<country name="Australie">
<noRegion>
<name sortKey="Van Zanten, Malou" sort="Van Zanten, Malou" uniqKey="Van Zanten M" first="Malou" last="Van Zanten">Malou Van Zanten</name>
</noRegion>
<name sortKey="Piller, Neil" sort="Piller, Neil" uniqKey="Piller N" first="Neil" last="Piller">Neil Piller</name>
<name sortKey="Ward, Leigh C" sort="Ward, Leigh C" uniqKey="Ward L" first="Leigh C" last="Ward">Leigh C. Ward</name>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Sante/explor/LymphedemaV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000F49 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 000F49 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Sante
   |area=    LymphedemaV1
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     pubmed:26574711
   |texte=   Inter-Changeability of Impedance Devices for Lymphedema Assessment.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Exploration/RBID.i   -Sk "pubmed:26574711" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd   \
       | NlmPubMed2Wicri -a LymphedemaV1 

Wicri

This area was generated with Dilib version V0.6.31.
Data generation: Sat Nov 4 17:40:35 2017. Site generation: Tue Feb 13 16:42:16 2024