The accuracy of dental radiographic techniques used for evaluation of implant fixture placement.
Identifieur interne : 004258 ( PubMed/Curation ); précédent : 004257; suivant : 004259The accuracy of dental radiographic techniques used for evaluation of implant fixture placement.
Auteurs : M E Gher [États-Unis] ; A C RichardsonSource :
- The International journal of periodontics & restorative dentistry [ 0198-7569 ] ; 1995.
Descripteurs français
- KwdFr :
- Humains, Mandibule (imagerie diagnostique), Mâchoire partiellement édentée (imagerie diagnostique), Planification des soins du patient, Pose d'implant dentaire endo-osseux, Processus alvéolaire (imagerie diagnostique), Radiographie dentaire (), Radiographie panoramique, Tomodensitométrie, Tomographie, Tomographie à rayons X ().
- MESH :
English descriptors
- KwdEn :
- Alveolar Process (diagnostic imaging), Dental Implantation, Endosseous, Humans, Jaw, Edentulous, Partially (diagnostic imaging), Mandible (diagnostic imaging), Patient Care Planning, Radiography, Dental (methods), Radiography, Panoramic, Tomography, Tomography, X-Ray (methods), Tomography, X-Ray Computed.
- MESH :
- diagnostic imaging : Alveolar Process, Jaw, Edentulous, Partially, Mandible.
- methods : Radiography, Dental, Tomography, X-Ray.
- Dental Implantation, Endosseous, Humans, Patient Care Planning, Radiography, Panoramic, Tomography, Tomography, X-Ray Computed.
Abstract
Periapical, panoramic, linear tomographic, and computerized tomographic radiographs were made of a partially dentate human mandible with four implants in place. Measurements taken from the radiographs and computer-generated images were compared to measurements made directly on the cross-sectioned test specimen. Periapical radiographs produced the most accurate measurements. Computerized and linear tomographic images provided the unique advantage of cross-sectional views of anatomic structures, but image blurring inherent to linear tomography and volume-averaging error inherent to computerized tomography affected the accuracy of measurements made from these images. The use of a dense dimensional reference object helped to compensate for radiographic distortion and is appropriate when projection radiographic techniques are used. The CT reference scale provided the most accurate method for interpreting measurements made from the computerized tomogram. The use of a dense dimensional reference object is inappropriate with CT because of its volume-averaging error.
PubMed: 7558660
Links toward previous steps (curation, corpus...)
- to stream PubMed, to step Corpus: Pour aller vers cette notice dans l'étape Curation :004258
Links to Exploration step
pubmed:7558660Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">The accuracy of dental radiographic techniques used for evaluation of implant fixture placement.</title>
<author><name sortKey="Gher, M E" sort="Gher, M E" uniqKey="Gher M" first="M E" last="Gher">M E Gher</name>
<affiliation wicri:level="1"><nlm:affiliation>Periodontics Department, Naval Dental Center, San Diego, California, USA.</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Periodontics Department, Naval Dental Center, San Diego, California</wicri:regionArea>
</affiliation>
</author>
<author><name sortKey="Richardson, A C" sort="Richardson, A C" uniqKey="Richardson A" first="A C" last="Richardson">A C Richardson</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="1995">1995</date>
<idno type="RBID">pubmed:7558660</idno>
<idno type="pmid">7558660</idno>
<idno type="wicri:Area/PubMed/Corpus">004258</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">004258</idno>
<idno type="wicri:Area/PubMed/Curation">004258</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">004258</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">The accuracy of dental radiographic techniques used for evaluation of implant fixture placement.</title>
<author><name sortKey="Gher, M E" sort="Gher, M E" uniqKey="Gher M" first="M E" last="Gher">M E Gher</name>
<affiliation wicri:level="1"><nlm:affiliation>Periodontics Department, Naval Dental Center, San Diego, California, USA.</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Periodontics Department, Naval Dental Center, San Diego, California</wicri:regionArea>
</affiliation>
</author>
<author><name sortKey="Richardson, A C" sort="Richardson, A C" uniqKey="Richardson A" first="A C" last="Richardson">A C Richardson</name>
</author>
</analytic>
<series><title level="j">The International journal of periodontics & restorative dentistry</title>
<idno type="ISSN">0198-7569</idno>
<imprint><date when="1995" type="published">1995</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Alveolar Process (diagnostic imaging)</term>
<term>Dental Implantation, Endosseous</term>
<term>Humans</term>
<term>Jaw, Edentulous, Partially (diagnostic imaging)</term>
<term>Mandible (diagnostic imaging)</term>
<term>Patient Care Planning</term>
<term>Radiography, Dental (methods)</term>
<term>Radiography, Panoramic</term>
<term>Tomography</term>
<term>Tomography, X-Ray (methods)</term>
<term>Tomography, X-Ray Computed</term>
</keywords>
<keywords scheme="KwdFr" xml:lang="fr"><term>Humains</term>
<term>Mandibule (imagerie diagnostique)</term>
<term>Mâchoire partiellement édentée (imagerie diagnostique)</term>
<term>Planification des soins du patient</term>
<term>Pose d'implant dentaire endo-osseux</term>
<term>Processus alvéolaire (imagerie diagnostique)</term>
<term>Radiographie dentaire ()</term>
<term>Radiographie panoramique</term>
<term>Tomodensitométrie</term>
<term>Tomographie</term>
<term>Tomographie à rayons X ()</term>
</keywords>
<keywords scheme="MESH" qualifier="diagnostic imaging" xml:lang="en"><term>Alveolar Process</term>
<term>Jaw, Edentulous, Partially</term>
<term>Mandible</term>
</keywords>
<keywords scheme="MESH" qualifier="imagerie diagnostique" xml:lang="fr"><term>Mandibule</term>
<term>Mâchoire partiellement édentée</term>
<term>Processus alvéolaire</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en"><term>Radiography, Dental</term>
<term>Tomography, X-Ray</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Dental Implantation, Endosseous</term>
<term>Humans</term>
<term>Patient Care Planning</term>
<term>Radiography, Panoramic</term>
<term>Tomography</term>
<term>Tomography, X-Ray Computed</term>
</keywords>
<keywords scheme="MESH" xml:lang="fr"><term>Humains</term>
<term>Planification des soins du patient</term>
<term>Pose d'implant dentaire endo-osseux</term>
<term>Radiographie dentaire</term>
<term>Radiographie panoramique</term>
<term>Tomodensitométrie</term>
<term>Tomographie</term>
<term>Tomographie à rayons X</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">Periapical, panoramic, linear tomographic, and computerized tomographic radiographs were made of a partially dentate human mandible with four implants in place. Measurements taken from the radiographs and computer-generated images were compared to measurements made directly on the cross-sectioned test specimen. Periapical radiographs produced the most accurate measurements. Computerized and linear tomographic images provided the unique advantage of cross-sectional views of anatomic structures, but image blurring inherent to linear tomography and volume-averaging error inherent to computerized tomography affected the accuracy of measurements made from these images. The use of a dense dimensional reference object helped to compensate for radiographic distortion and is appropriate when projection radiographic techniques are used. The CT reference scale provided the most accurate method for interpreting measurements made from the computerized tomogram. The use of a dense dimensional reference object is inappropriate with CT because of its volume-averaging error.</div>
</front>
</TEI>
<pubmed><MedlineCitation Status="MEDLINE" Owner="NLM"><PMID Version="1">7558660</PMID>
<DateCompleted><Year>1995</Year>
<Month>10</Month>
<Day>23</Day>
</DateCompleted>
<DateRevised><Year>2016</Year>
<Month>11</Month>
<Day>23</Day>
</DateRevised>
<Article PubModel="Print"><Journal><ISSN IssnType="Print">0198-7569</ISSN>
<JournalIssue CitedMedium="Print"><Volume>15</Volume>
<Issue>3</Issue>
<PubDate><Year>1995</Year>
<Month>Jun</Month>
</PubDate>
</JournalIssue>
<Title>The International journal of periodontics & restorative dentistry</Title>
<ISOAbbreviation>Int J Periodontics Restorative Dent</ISOAbbreviation>
</Journal>
<ArticleTitle>The accuracy of dental radiographic techniques used for evaluation of implant fixture placement.</ArticleTitle>
<Pagination><MedlinePgn>268-83</MedlinePgn>
</Pagination>
<Abstract><AbstractText>Periapical, panoramic, linear tomographic, and computerized tomographic radiographs were made of a partially dentate human mandible with four implants in place. Measurements taken from the radiographs and computer-generated images were compared to measurements made directly on the cross-sectioned test specimen. Periapical radiographs produced the most accurate measurements. Computerized and linear tomographic images provided the unique advantage of cross-sectional views of anatomic structures, but image blurring inherent to linear tomography and volume-averaging error inherent to computerized tomography affected the accuracy of measurements made from these images. The use of a dense dimensional reference object helped to compensate for radiographic distortion and is appropriate when projection radiographic techniques are used. The CT reference scale provided the most accurate method for interpreting measurements made from the computerized tomogram. The use of a dense dimensional reference object is inappropriate with CT because of its volume-averaging error.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y"><Author ValidYN="Y"><LastName>Gher</LastName>
<ForeName>M E</ForeName>
<Initials>ME</Initials>
<AffiliationInfo><Affiliation>Periodontics Department, Naval Dental Center, San Diego, California, USA.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y"><LastName>Richardson</LastName>
<ForeName>A C</ForeName>
<Initials>AC</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList><PublicationType UI="D003160">Comparative Study</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo><Country>United States</Country>
<MedlineTA>Int J Periodontics Restorative Dent</MedlineTA>
<NlmUniqueID>8200894</NlmUniqueID>
<ISSNLinking>0198-7569</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>D</CitationSubset>
<MeshHeadingList><MeshHeading><DescriptorName UI="D000539" MajorTopicYN="N">Alveolar Process</DescriptorName>
<QualifierName UI="Q000000981" MajorTopicYN="N">diagnostic imaging</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D003758" MajorTopicYN="Y">Dental Implantation, Endosseous</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D007576" MajorTopicYN="N">Jaw, Edentulous, Partially</DescriptorName>
<QualifierName UI="Q000000981" MajorTopicYN="Y">diagnostic imaging</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D008334" MajorTopicYN="N">Mandible</DescriptorName>
<QualifierName UI="Q000000981" MajorTopicYN="N">diagnostic imaging</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D010347" MajorTopicYN="N">Patient Care Planning</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D011861" MajorTopicYN="N">Radiography, Dental</DescriptorName>
<QualifierName UI="Q000379" MajorTopicYN="Y">methods</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D011862" MajorTopicYN="N">Radiography, Panoramic</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D014054" MajorTopicYN="N">Tomography</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D014056" MajorTopicYN="N">Tomography, X-Ray</DescriptorName>
<QualifierName UI="Q000379" MajorTopicYN="N">methods</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D014057" MajorTopicYN="N">Tomography, X-Ray Computed</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData><History><PubMedPubDate PubStatus="pubmed"><Year>1995</Year>
<Month>6</Month>
<Day>1</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline"><Year>1995</Year>
<Month>6</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>1</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez"><Year>1995</Year>
<Month>6</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList><ArticleId IdType="pubmed">7558660</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/PubMed/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 004258 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd -nk 004258 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Santé |area= EdenteV2 |flux= PubMed |étape= Curation |type= RBID |clé= pubmed:7558660 |texte= The accuracy of dental radiographic techniques used for evaluation of implant fixture placement. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Curation/RBID.i -Sk "pubmed:7558660" \ | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd \ | NlmPubMed2Wicri -a EdenteV2
This area was generated with Dilib version V0.6.32. |