The influence of splinting procedures on the periodontal and peri-implant tissue damping characteristics. A longitudinal study with the Periotest device.

Identifieur interne : 004210 ( PubMed/Corpus ); précédent : 004209; suivant : 004211

The influence of splinting procedures on the periodontal and peri-implant tissue damping characteristics. A longitudinal study with the Periotest device.

Auteurs : I E Naert ; D. Rosenberg ; D. Van Steenberghe ; J A Tricio ; M. Nys

Source :

RBID : pubmed:7593701

English descriptors

Abstract

The aim of the present study was to evaluate the capability of the Periotest device in detecting and monitoring functional changes in the periodontal as well as in the pari-implant damping characteristics. In the first part of this study, 107 teeth were splinted by means of 40 full acrylic fixed prostheses (AFP) and another 37 teeth were splinted by means of 14 ceramometallic fixed prostheses (C-MFP). The Periotest measurements of individual teeth were done the day the fixed prostheses were cemented temporary (PTV 1), and again after a mean observation period of 27.4 days (PTV 2). In the 2nd part, 78 osseointegrated two-stage implants were splinted by means of 23 full acrylic fixed prosthesis (AFP) and other 18 implants were left without it. Using the same abutment length, Periotest measurements were performed, at abutment connections and before installation of the final prosthesis. In a 3rd part, using both implants and teeth as abutments, 29 osseointegrated implants were connected with 25 abutment teeth by means of 7 AFP. The measurements were performed at the beginning of the prosthetic treatment and 2, 4 and 6 weeks later. After splinting teeth by means of AFP for the observation period, no statistically significant reduction in PTVs was found. When on the other hand, a C-MFP was used, PTV 2 showed a significant reduction. The PTVs at abutment connection went down after a period of time, during which some implants were interconnected by means of an AFP and others were not.(ABSTRACT TRUNCATED AT 250 WORDS)

PubMed: 7593701

Links to Exploration step

pubmed:7593701

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">The influence of splinting procedures on the periodontal and peri-implant tissue damping characteristics. A longitudinal study with the Periotest device.</title>
<author>
<name sortKey="Naert, I E" sort="Naert, I E" uniqKey="Naert I" first="I E" last="Naert">I E Naert</name>
<affiliation>
<nlm:affiliation>Department of Prosthetic Dentistry, Faculty of Medicine, Catholic University of Leuven, Belgium.</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Rosenberg, D" sort="Rosenberg, D" uniqKey="Rosenberg D" first="D" last="Rosenberg">D. Rosenberg</name>
</author>
<author>
<name sortKey="Van Steenberghe, D" sort="Van Steenberghe, D" uniqKey="Van Steenberghe D" first="D" last="Van Steenberghe">D. Van Steenberghe</name>
</author>
<author>
<name sortKey="Tricio, J A" sort="Tricio, J A" uniqKey="Tricio J" first="J A" last="Tricio">J A Tricio</name>
</author>
<author>
<name sortKey="Nys, M" sort="Nys, M" uniqKey="Nys M" first="M" last="Nys">M. Nys</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="1995">1995</date>
<idno type="RBID">pubmed:7593701</idno>
<idno type="pmid">7593701</idno>
<idno type="wicri:Area/PubMed/Corpus">004210</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">004210</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">The influence of splinting procedures on the periodontal and peri-implant tissue damping characteristics. A longitudinal study with the Periotest device.</title>
<author>
<name sortKey="Naert, I E" sort="Naert, I E" uniqKey="Naert I" first="I E" last="Naert">I E Naert</name>
<affiliation>
<nlm:affiliation>Department of Prosthetic Dentistry, Faculty of Medicine, Catholic University of Leuven, Belgium.</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Rosenberg, D" sort="Rosenberg, D" uniqKey="Rosenberg D" first="D" last="Rosenberg">D. Rosenberg</name>
</author>
<author>
<name sortKey="Van Steenberghe, D" sort="Van Steenberghe, D" uniqKey="Van Steenberghe D" first="D" last="Van Steenberghe">D. Van Steenberghe</name>
</author>
<author>
<name sortKey="Tricio, J A" sort="Tricio, J A" uniqKey="Tricio J" first="J A" last="Tricio">J A Tricio</name>
</author>
<author>
<name sortKey="Nys, M" sort="Nys, M" uniqKey="Nys M" first="M" last="Nys">M. Nys</name>
</author>
</analytic>
<series>
<title level="j">Journal of clinical periodontology</title>
<idno type="ISSN">0303-6979</idno>
<imprint>
<date when="1995" type="published">1995</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Acrylic Resins</term>
<term>Adult</term>
<term>Aged</term>
<term>Aged, 80 and over</term>
<term>Biomechanical Phenomena</term>
<term>Cementation</term>
<term>Dental Abutments</term>
<term>Dental Implantation, Endosseous</term>
<term>Dental Implants</term>
<term>Denture Design</term>
<term>Denture, Partial, Fixed</term>
<term>Denture, Partial, Temporary</term>
<term>Female</term>
<term>Follow-Up Studies</term>
<term>Humans</term>
<term>Jaw, Edentulous, Partially (rehabilitation)</term>
<term>Longitudinal Studies</term>
<term>Male</term>
<term>Metal Ceramic Alloys</term>
<term>Middle Aged</term>
<term>Monitoring, Physiologic</term>
<term>Osseointegration</term>
<term>Periodontics (instrumentation)</term>
<term>Periodontium (physiology)</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en">
<term>Acrylic Resins</term>
<term>Dental Implants</term>
<term>Metal Ceramic Alloys</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en">
<term>Periodontics</term>
</keywords>
<keywords scheme="MESH" qualifier="physiology" xml:lang="en">
<term>Periodontium</term>
</keywords>
<keywords scheme="MESH" qualifier="rehabilitation" xml:lang="en">
<term>Jaw, Edentulous, Partially</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Adult</term>
<term>Aged</term>
<term>Aged, 80 and over</term>
<term>Biomechanical Phenomena</term>
<term>Cementation</term>
<term>Dental Abutments</term>
<term>Dental Implantation, Endosseous</term>
<term>Denture Design</term>
<term>Denture, Partial, Fixed</term>
<term>Denture, Partial, Temporary</term>
<term>Female</term>
<term>Follow-Up Studies</term>
<term>Humans</term>
<term>Longitudinal Studies</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Monitoring, Physiologic</term>
<term>Osseointegration</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">The aim of the present study was to evaluate the capability of the Periotest device in detecting and monitoring functional changes in the periodontal as well as in the pari-implant damping characteristics. In the first part of this study, 107 teeth were splinted by means of 40 full acrylic fixed prostheses (AFP) and another 37 teeth were splinted by means of 14 ceramometallic fixed prostheses (C-MFP). The Periotest measurements of individual teeth were done the day the fixed prostheses were cemented temporary (PTV 1), and again after a mean observation period of 27.4 days (PTV 2). In the 2nd part, 78 osseointegrated two-stage implants were splinted by means of 23 full acrylic fixed prosthesis (AFP) and other 18 implants were left without it. Using the same abutment length, Periotest measurements were performed, at abutment connections and before installation of the final prosthesis. In a 3rd part, using both implants and teeth as abutments, 29 osseointegrated implants were connected with 25 abutment teeth by means of 7 AFP. The measurements were performed at the beginning of the prosthetic treatment and 2, 4 and 6 weeks later. After splinting teeth by means of AFP for the observation period, no statistically significant reduction in PTVs was found. When on the other hand, a C-MFP was used, PTV 2 showed a significant reduction. The PTVs at abutment connection went down after a period of time, during which some implants were interconnected by means of an AFP and others were not.(ABSTRACT TRUNCATED AT 250 WORDS)</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Status="MEDLINE" Owner="NLM">
<PMID Version="1">7593701</PMID>
<DateCompleted>
<Year>1995</Year>
<Month>12</Month>
<Day>15</Day>
</DateCompleted>
<DateRevised>
<Year>2013</Year>
<Month>11</Month>
<Day>21</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">0303-6979</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>22</Volume>
<Issue>9</Issue>
<PubDate>
<Year>1995</Year>
<Month>Sep</Month>
</PubDate>
</JournalIssue>
<Title>Journal of clinical periodontology</Title>
<ISOAbbreviation>J. Clin. Periodontol.</ISOAbbreviation>
</Journal>
<ArticleTitle>The influence of splinting procedures on the periodontal and peri-implant tissue damping characteristics. A longitudinal study with the Periotest device.</ArticleTitle>
<Pagination>
<MedlinePgn>703-8</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText>The aim of the present study was to evaluate the capability of the Periotest device in detecting and monitoring functional changes in the periodontal as well as in the pari-implant damping characteristics. In the first part of this study, 107 teeth were splinted by means of 40 full acrylic fixed prostheses (AFP) and another 37 teeth were splinted by means of 14 ceramometallic fixed prostheses (C-MFP). The Periotest measurements of individual teeth were done the day the fixed prostheses were cemented temporary (PTV 1), and again after a mean observation period of 27.4 days (PTV 2). In the 2nd part, 78 osseointegrated two-stage implants were splinted by means of 23 full acrylic fixed prosthesis (AFP) and other 18 implants were left without it. Using the same abutment length, Periotest measurements were performed, at abutment connections and before installation of the final prosthesis. In a 3rd part, using both implants and teeth as abutments, 29 osseointegrated implants were connected with 25 abutment teeth by means of 7 AFP. The measurements were performed at the beginning of the prosthetic treatment and 2, 4 and 6 weeks later. After splinting teeth by means of AFP for the observation period, no statistically significant reduction in PTVs was found. When on the other hand, a C-MFP was used, PTV 2 showed a significant reduction. The PTVs at abutment connection went down after a period of time, during which some implants were interconnected by means of an AFP and others were not.(ABSTRACT TRUNCATED AT 250 WORDS)</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Naert</LastName>
<ForeName>I E</ForeName>
<Initials>IE</Initials>
<AffiliationInfo>
<Affiliation>Department of Prosthetic Dentistry, Faculty of Medicine, Catholic University of Leuven, Belgium.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Rosenberg</LastName>
<ForeName>D</ForeName>
<Initials>D</Initials>
</Author>
<Author ValidYN="Y">
<LastName>van Steenberghe</LastName>
<ForeName>D</ForeName>
<Initials>D</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Tricio</LastName>
<ForeName>J A</ForeName>
<Initials>JA</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Nys</LastName>
<ForeName>M</ForeName>
<Initials>M</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>United States</Country>
<MedlineTA>J Clin Periodontol</MedlineTA>
<NlmUniqueID>0425123</NlmUniqueID>
<ISSNLinking>0303-6979</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D000180">Acrylic Resins</NameOfSubstance>
</Chemical>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D015921">Dental Implants</NameOfSubstance>
</Chemical>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D016876">Metal Ceramic Alloys</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>D</CitationSubset>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName UI="D000180" MajorTopicYN="N">Acrylic Resins</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D000328" MajorTopicYN="N">Adult</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D000368" MajorTopicYN="N">Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D000369" MajorTopicYN="N">Aged, 80 and over</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D001696" MajorTopicYN="N">Biomechanical Phenomena</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D002484" MajorTopicYN="N">Cementation</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D000044" MajorTopicYN="Y">Dental Abutments</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003758" MajorTopicYN="Y">Dental Implantation, Endosseous</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D015921" MajorTopicYN="Y">Dental Implants</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003779" MajorTopicYN="N">Denture Design</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003830" MajorTopicYN="Y">Denture, Partial, Fixed</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003833" MajorTopicYN="N">Denture, Partial, Temporary</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D005260" MajorTopicYN="N">Female</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D005500" MajorTopicYN="N">Follow-Up Studies</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D007576" MajorTopicYN="N">Jaw, Edentulous, Partially</DescriptorName>
<QualifierName UI="Q000534" MajorTopicYN="N">rehabilitation</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008137" MajorTopicYN="N">Longitudinal Studies</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008297" MajorTopicYN="N">Male</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D016876" MajorTopicYN="N">Metal Ceramic Alloys</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008875" MajorTopicYN="N">Middle Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008991" MajorTopicYN="N">Monitoring, Physiologic</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D016348" MajorTopicYN="N">Osseointegration</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D010517" MajorTopicYN="N">Periodontics</DescriptorName>
<QualifierName UI="Q000295" MajorTopicYN="Y">instrumentation</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D010519" MajorTopicYN="N">Periodontium</DescriptorName>
<QualifierName UI="Q000502" MajorTopicYN="Y">physiology</QualifierName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="pubmed">
<Year>1995</Year>
<Month>9</Month>
<Day>1</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>1995</Year>
<Month>9</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>1</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>1995</Year>
<Month>9</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">7593701</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 004210 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 004210 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    PubMed
   |étape=   Corpus
   |type=    RBID
   |clé=     pubmed:7593701
   |texte=   The influence of splinting procedures on the periodontal and peri-implant tissue damping characteristics. A longitudinal study with the Periotest device.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i   -Sk "pubmed:7593701" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV2 

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022