Clinical experiences of computer numeric control-milled titanium frameworks supported by implants in the edentulous jaw: a 5-year prospective study.

Identifieur interne : 002D25 ( PubMed/Corpus ); précédent : 002D24; suivant : 002D26

Clinical experiences of computer numeric control-milled titanium frameworks supported by implants in the edentulous jaw: a 5-year prospective study.

Auteurs : Anders Ortorp ; Torsten Jemt

Source :

RBID : pubmed:15841580

English descriptors

Abstract

Few long-term follow-up studies on treatment concepts using computer numeric control-milled titanium frameworks have been conducted.

PubMed: 15841580

Links to Exploration step

pubmed:15841580

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Clinical experiences of computer numeric control-milled titanium frameworks supported by implants in the edentulous jaw: a 5-year prospective study.</title>
<author>
<name sortKey="Ortorp, Anders" sort="Ortorp, Anders" uniqKey="Ortorp A" first="Anders" last="Ortorp">Anders Ortorp</name>
<affiliation>
<nlm:affiliation>The Brånemark Clinic, Public Dental Health, Göteborg, Sweden. anders.ortorp@vgregion.se</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Jemt, Torsten" sort="Jemt, Torsten" uniqKey="Jemt T" first="Torsten" last="Jemt">Torsten Jemt</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2004">2004</date>
<idno type="RBID">pubmed:15841580</idno>
<idno type="pmid">15841580</idno>
<idno type="wicri:Area/PubMed/Corpus">002D25</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">002D25</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Clinical experiences of computer numeric control-milled titanium frameworks supported by implants in the edentulous jaw: a 5-year prospective study.</title>
<author>
<name sortKey="Ortorp, Anders" sort="Ortorp, Anders" uniqKey="Ortorp A" first="Anders" last="Ortorp">Anders Ortorp</name>
<affiliation>
<nlm:affiliation>The Brånemark Clinic, Public Dental Health, Göteborg, Sweden. anders.ortorp@vgregion.se</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Jemt, Torsten" sort="Jemt, Torsten" uniqKey="Jemt T" first="Torsten" last="Jemt">Torsten Jemt</name>
</author>
</analytic>
<series>
<title level="j">Clinical implant dentistry and related research</title>
<idno type="ISSN">1523-0899</idno>
<imprint>
<date when="2004" type="published">2004</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Aged</term>
<term>Aged, 80 and over</term>
<term>Alveolar Bone Loss (diagnostic imaging)</term>
<term>Alveolar Bone Loss (etiology)</term>
<term>Computer-Aided Design</term>
<term>Dental Implantation, Endosseous</term>
<term>Dental Implants (adverse effects)</term>
<term>Dental Prosthesis Design</term>
<term>Dental Prosthesis Retention</term>
<term>Dental Prosthesis, Implant-Supported (adverse effects)</term>
<term>Dental Restoration Failure</term>
<term>Female</term>
<term>Follow-Up Studies</term>
<term>Gold Alloys</term>
<term>Humans</term>
<term>Jaw, Edentulous (rehabilitation)</term>
<term>Life Tables</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Prospective Studies</term>
<term>Radiography</term>
<term>Statistics, Nonparametric</term>
<term>Titanium</term>
</keywords>
<keywords scheme="MESH" type="chemical" qualifier="adverse effects" xml:lang="en">
<term>Dental Implants</term>
</keywords>
<keywords scheme="MESH" qualifier="adverse effects" xml:lang="en">
<term>Dental Prosthesis, Implant-Supported</term>
</keywords>
<keywords scheme="MESH" qualifier="diagnostic imaging" xml:lang="en">
<term>Alveolar Bone Loss</term>
</keywords>
<keywords scheme="MESH" qualifier="etiology" xml:lang="en">
<term>Alveolar Bone Loss</term>
</keywords>
<keywords scheme="MESH" qualifier="rehabilitation" xml:lang="en">
<term>Jaw, Edentulous</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Aged</term>
<term>Aged, 80 and over</term>
<term>Computer-Aided Design</term>
<term>Dental Implantation, Endosseous</term>
<term>Dental Prosthesis Design</term>
<term>Dental Prosthesis Retention</term>
<term>Dental Restoration Failure</term>
<term>Female</term>
<term>Follow-Up Studies</term>
<term>Gold Alloys</term>
<term>Humans</term>
<term>Life Tables</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Prospective Studies</term>
<term>Radiography</term>
<term>Statistics, Nonparametric</term>
<term>Titanium</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Few long-term follow-up studies on treatment concepts using computer numeric control-milled titanium frameworks have been conducted.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Status="MEDLINE" Owner="NLM">
<PMID Version="1">15841580</PMID>
<DateCompleted>
<Year>2005</Year>
<Month>05</Month>
<Day>02</Day>
</DateCompleted>
<DateRevised>
<Year>2016</Year>
<Month>11</Month>
<Day>24</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">1523-0899</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>6</Volume>
<Issue>4</Issue>
<PubDate>
<Year>2004</Year>
</PubDate>
</JournalIssue>
<Title>Clinical implant dentistry and related research</Title>
<ISOAbbreviation>Clin Implant Dent Relat Res</ISOAbbreviation>
</Journal>
<ArticleTitle>Clinical experiences of computer numeric control-milled titanium frameworks supported by implants in the edentulous jaw: a 5-year prospective study.</ArticleTitle>
<Pagination>
<MedlinePgn>199-209</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText Label="BACKGROUND" NlmCategory="BACKGROUND">Few long-term follow-up studies on treatment concepts using computer numeric control-milled titanium frameworks have been conducted.</AbstractText>
<AbstractText Label="OBJECTIVE" NlmCategory="OBJECTIVE">To evaluate the clinical and radiographic performance of implant-supported prostheses provided with computer numeric control-milled titanium frameworks in the edentulous jaw and to compare their performance during the first 5 years of function with that of prostheses provided with conventional cast gold alloy frameworks.</AbstractText>
<AbstractText Label="MATERIALS AND METHODS" NlmCategory="METHODS">A consecutive group of 126 edentulous patients were randomly provided with 67 prostheses with titanium frameworks (test group) in 23 upper jaws and 44 lower jaws and with 62 conventional prostheses with gold alloy castings (control group) in 31 upper jaws and 31 lower jaws. Clinical and radiographic 5-year data were collected for the test and control groups.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">The frequency of problems was low, and clinical and radiologic performances were similar in both groups. In the test group, the 5-year cumulative survival rates (CSRs) were 94.9% and 98.3% for implants and titanium prostheses, respectively. The respective corresponding CSRs for the control group were 97.9% and 98.2%. More loaded implants were lost in the maxillas in the test group (p < .01), but this difference was not significant on the patient/prosthesis level (p > .05). Smokers lost more implants than nonsmokers lost (p < .01). Similar survival rates were observed for implants in the mandible. One prosthesis was lost in each group because of the loss of implants. Metal fractures were seen only in the control group, and resin veneer fractures were more frequent in the maxilla in the gold alloy group (p < .05). In the test group, the mean marginal bone loss was 0.5 mm (SD, 0.44) in the maxilla and 0.4 mm (SD, 0.50) in the mandible. A similar pattern of bone reaction was observed in the control group. Mean marginal bone loss was similar for smokers and nonsmokers (p > .05).</AbstractText>
<AbstractText Label="CONCLUSION" NlmCategory="CONCLUSIONS">Computer numeric control-milled titanium frameworks are a viable alternative to gold alloy castings in the edentulous jaw and present clinical and radiologic performances similar to those of conventional gold alloy frameworks during the first 5 years of function.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Ortorp</LastName>
<ForeName>Anders</ForeName>
<Initials>A</Initials>
<AffiliationInfo>
<Affiliation>The Brånemark Clinic, Public Dental Health, Göteborg, Sweden. anders.ortorp@vgregion.se</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Jemt</LastName>
<ForeName>Torsten</ForeName>
<Initials>T</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016430">Clinical Trial</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
<PublicationType UI="D016449">Randomized Controlled Trial</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>United States</Country>
<MedlineTA>Clin Implant Dent Relat Res</MedlineTA>
<NlmUniqueID>100888977</NlmUniqueID>
<ISSNLinking>1523-0899</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D015921">Dental Implants</NameOfSubstance>
</Chemical>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D006047">Gold Alloys</NameOfSubstance>
</Chemical>
<Chemical>
<RegistryNumber>D1JT611TNE</RegistryNumber>
<NameOfSubstance UI="D014025">Titanium</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>D</CitationSubset>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName UI="D000368" MajorTopicYN="N">Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D000369" MajorTopicYN="N">Aged, 80 and over</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D016301" MajorTopicYN="N">Alveolar Bone Loss</DescriptorName>
<QualifierName UI="Q000000981" MajorTopicYN="N">diagnostic imaging</QualifierName>
<QualifierName UI="Q000209" MajorTopicYN="N">etiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D017076" MajorTopicYN="Y">Computer-Aided Design</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003758" MajorTopicYN="N">Dental Implantation, Endosseous</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D015921" MajorTopicYN="N">Dental Implants</DescriptorName>
<QualifierName UI="Q000009" MajorTopicYN="N">adverse effects</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D017267" MajorTopicYN="Y">Dental Prosthesis Design</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D017268" MajorTopicYN="N">Dental Prosthesis Retention</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D019094" MajorTopicYN="Y">Dental Prosthesis, Implant-Supported</DescriptorName>
<QualifierName UI="Q000009" MajorTopicYN="N">adverse effects</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D019232" MajorTopicYN="N">Dental Restoration Failure</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D005260" MajorTopicYN="N">Female</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D005500" MajorTopicYN="N">Follow-Up Studies</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D006047" MajorTopicYN="N">Gold Alloys</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D007575" MajorTopicYN="N">Jaw, Edentulous</DescriptorName>
<QualifierName UI="Q000534" MajorTopicYN="Y">rehabilitation</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D015993" MajorTopicYN="N">Life Tables</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008297" MajorTopicYN="N">Male</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008875" MajorTopicYN="N">Middle Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D011446" MajorTopicYN="N">Prospective Studies</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D011859" MajorTopicYN="N">Radiography</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D018709" MajorTopicYN="N">Statistics, Nonparametric</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D014025" MajorTopicYN="N">Titanium</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="pubmed">
<Year>2005</Year>
<Month>4</Month>
<Day>22</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2005</Year>
<Month>5</Month>
<Day>3</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>2005</Year>
<Month>4</Month>
<Day>22</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">15841580</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 002D25 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 002D25 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    PubMed
   |étape=   Corpus
   |type=    RBID
   |clé=     pubmed:15841580
   |texte=   Clinical experiences of computer numeric control-milled titanium frameworks supported by implants in the edentulous jaw: a 5-year prospective study.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i   -Sk "pubmed:15841580" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV2 

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022