The Effects of Superficial Roughness and Design on the Primary Stability of Dental Implants
Identifieur interne : 004509 ( Main/Merge ); précédent : 004508; suivant : 004510The Effects of Superficial Roughness and Design on the Primary Stability of Dental Implants
Auteurs : Mychelle Vianna Dos Santos [Brésil] ; Carlos Nelson Elias [Brésil] ; Jose Henrique Cavalcanti Lima [Brésil]Source :
- Clinical Implant Dentistry and Related Research [ 1523-0899 ] ; 2011-09.
English descriptors
- KwdEn :
- Anodized, Bone density, Carlos nelson elias, Clinical implant dentistry, Conical, Conical implant, Contact area, Cortical bone, Cylindrical drill, Cylindrical implant, Cylindrical implants, Dental implant, Dental implants, Fastening screws, Greater roughness, Higher friction, Highest insertion torque, Hmwpe, Hmwpe cylinder, Hmwpe cylinders, Homogeneous material, Immediate loading, Implant, Implant design, Implant geometry, Implant insertion, Implant placement, Implant stability, Implant stability quotient, Implant stabilization, Implant surface, Implant surface morphology, Implant surface treatment, Implant surface treatments, Implant surfaces, Implant thread geometry, Insertion, Insertion torque, Insertion torque increases, Insertion torques, Instituto militar, Integration diagnostics, Larger insertion torque, Machined, Machined implants, Maxillofac, Maximum implant insertion torque, Mechanical properties, More parts, Morphology, Nishing, Nishing surface, Nobel biocare, Oral maxillofac implants, Osstell mentor, Pilot drill, Present work, Primary stability, Resonance frequency, Resonance frequency analysis, Resonance frequency measurements, Roughness, Roughness parameters, Statistical analysis, Surface area, Surface morphology, Surface roughness, Surface treatment, Surface treatments, Surgical, Surgical protocol, Thread form, Thread geometry, Torque, Weight polyethylene.
- Teeft :
- Anodized, Bone density, Carlos nelson elias, Clinical implant dentistry, Conical, Conical implant, Contact area, Cortical bone, Cylindrical drill, Cylindrical implant, Cylindrical implants, Dental implant, Dental implants, Fastening screws, Greater roughness, Higher friction, Highest insertion torque, Hmwpe, Hmwpe cylinder, Hmwpe cylinders, Homogeneous material, Immediate loading, Implant, Implant design, Implant geometry, Implant insertion, Implant placement, Implant stability, Implant stability quotient, Implant stabilization, Implant surface, Implant surface morphology, Implant surface treatment, Implant surface treatments, Implant surfaces, Implant thread geometry, Insertion, Insertion torque, Insertion torque increases, Insertion torques, Instituto militar, Integration diagnostics, Larger insertion torque, Machined, Machined implants, Maxillofac, Maximum implant insertion torque, Mechanical properties, More parts, Morphology, Nishing, Nishing surface, Nobel biocare, Oral maxillofac implants, Osstell mentor, Pilot drill, Present work, Primary stability, Resonance frequency, Resonance frequency analysis, Resonance frequency measurements, Roughness, Roughness parameters, Statistical analysis, Surface area, Surface morphology, Surface roughness, Surface treatment, Surface treatments, Surgical, Surgical protocol, Thread form, Thread geometry, Torque, Weight polyethylene.
Abstract
Background: Primary implant stability has been used as an indicator for future osseointegration and whether an immediate/early loading protocol should be applied. Implant stability is the key to clinical success.
Url:
DOI: 10.1111/j.1708-8208.2009.00202.x
Links toward previous steps (curation, corpus...)
- to stream Istex, to step Corpus: 007C53
- to stream Istex, to step Curation: 007C53
- to stream Istex, to step Checkpoint: 001425
Links to Exploration step
ISTEX:FBBCB3694511D235E27CF4114620017CDA5D5D7DLe document en format XML
<record><TEI wicri:istexFullTextTei="biblStruct"><teiHeader><fileDesc><titleStmt><title xml:lang="en">The Effects of Superficial Roughness and Design on the Primary Stability of Dental Implants</title>
<author><name sortKey="Dos Santos, Mychelle Vianna" sort="Dos Santos, Mychelle Vianna" uniqKey="Dos Santos M" first="Mychelle Vianna" last="Dos Santos">Mychelle Vianna Dos Santos</name>
</author>
<author><name sortKey="Elias, Carlos Nelson" sort="Elias, Carlos Nelson" uniqKey="Elias C" first="Carlos Nelson" last="Elias">Carlos Nelson Elias</name>
</author>
<author><name sortKey="Cavalcanti Lima, Jose Henrique" sort="Cavalcanti Lima, Jose Henrique" uniqKey="Cavalcanti Lima J" first="Jose Henrique" last="Cavalcanti Lima">Jose Henrique Cavalcanti Lima</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:FBBCB3694511D235E27CF4114620017CDA5D5D7D</idno>
<date when="2011" year="2011">2011</date>
<idno type="doi">10.1111/j.1708-8208.2009.00202.x</idno>
<idno type="url">https://api.istex.fr/document/FBBCB3694511D235E27CF4114620017CDA5D5D7D/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">007C53</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Corpus" wicri:corpus="ISTEX">007C53</idno>
<idno type="wicri:Area/Istex/Curation">007C53</idno>
<idno type="wicri:Area/Istex/Checkpoint">001425</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Checkpoint">001425</idno>
<idno type="wicri:doubleKey">1523-0899:2011:Dos Santos M:the:effects:of</idno>
<idno type="wicri:Area/Main/Merge">004509</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title level="a" type="main">The Effects of Superficial Roughness and Design on the Primary Stability of Dental Implants</title>
<author><name sortKey="Dos Santos, Mychelle Vianna" sort="Dos Santos, Mychelle Vianna" uniqKey="Dos Santos M" first="Mychelle Vianna" last="Dos Santos">Mychelle Vianna Dos Santos</name>
<affiliation wicri:level="2"><country xml:lang="fr" wicri:curation="lc">Brésil</country>
<wicri:regionArea>Biomaterials Laboratory, Instituto Militar de Engenharia, Rio de Janeiro, RJ</wicri:regionArea>
<placeName><region type="state">État de Rio de Janeiro</region>
</placeName>
</affiliation>
</author>
<author><name sortKey="Elias, Carlos Nelson" sort="Elias, Carlos Nelson" uniqKey="Elias C" first="Carlos Nelson" last="Elias">Carlos Nelson Elias</name>
<affiliation wicri:level="2"><country xml:lang="fr" wicri:curation="lc">Brésil</country>
<wicri:regionArea>Biomaterials Laboratory, Instituto Militar de Engenharia, Rio de Janeiro, RJ</wicri:regionArea>
<placeName><region type="state">État de Rio de Janeiro</region>
</placeName>
</affiliation>
<affiliation wicri:level="1"><country wicri:rule="url">Brésil</country>
</affiliation>
</author>
<author><name sortKey="Cavalcanti Lima, Jose Henrique" sort="Cavalcanti Lima, Jose Henrique" uniqKey="Cavalcanti Lima J" first="Jose Henrique" last="Cavalcanti Lima">Jose Henrique Cavalcanti Lima</name>
<affiliation wicri:level="2"><country xml:lang="fr">Brésil</country>
<wicri:regionArea>INCO25 Av Rio Branco 124, Rio de Janeiro, RJ</wicri:regionArea>
<placeName><region type="state">État de Rio de Janeiro</region>
</placeName>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series><title level="j" type="main">Clinical Implant Dentistry and Related Research</title>
<title level="j" type="alt">CLINICAL IMPLANT DENTISTRY RELATED RESEARCH</title>
<idno type="ISSN">1523-0899</idno>
<idno type="eISSN">1708-8208</idno>
<imprint><biblScope unit="vol">13</biblScope>
<biblScope unit="issue">3</biblScope>
<biblScope unit="page" from="215">215</biblScope>
<biblScope unit="page" to="223">223</biblScope>
<biblScope unit="page-count">9</biblScope>
<publisher>Blackwell Publishing Ltd</publisher>
<pubPlace>Oxford, UK</pubPlace>
<date type="published" when="2011-09">2011-09</date>
</imprint>
<idno type="ISSN">1523-0899</idno>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt><idno type="ISSN">1523-0899</idno>
</seriesStmt>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Anodized</term>
<term>Bone density</term>
<term>Carlos nelson elias</term>
<term>Clinical implant dentistry</term>
<term>Conical</term>
<term>Conical implant</term>
<term>Contact area</term>
<term>Cortical bone</term>
<term>Cylindrical drill</term>
<term>Cylindrical implant</term>
<term>Cylindrical implants</term>
<term>Dental implant</term>
<term>Dental implants</term>
<term>Fastening screws</term>
<term>Greater roughness</term>
<term>Higher friction</term>
<term>Highest insertion torque</term>
<term>Hmwpe</term>
<term>Hmwpe cylinder</term>
<term>Hmwpe cylinders</term>
<term>Homogeneous material</term>
<term>Immediate loading</term>
<term>Implant</term>
<term>Implant design</term>
<term>Implant geometry</term>
<term>Implant insertion</term>
<term>Implant placement</term>
<term>Implant stability</term>
<term>Implant stability quotient</term>
<term>Implant stabilization</term>
<term>Implant surface</term>
<term>Implant surface morphology</term>
<term>Implant surface treatment</term>
<term>Implant surface treatments</term>
<term>Implant surfaces</term>
<term>Implant thread geometry</term>
<term>Insertion</term>
<term>Insertion torque</term>
<term>Insertion torque increases</term>
<term>Insertion torques</term>
<term>Instituto militar</term>
<term>Integration diagnostics</term>
<term>Larger insertion torque</term>
<term>Machined</term>
<term>Machined implants</term>
<term>Maxillofac</term>
<term>Maximum implant insertion torque</term>
<term>Mechanical properties</term>
<term>More parts</term>
<term>Morphology</term>
<term>Nishing</term>
<term>Nishing surface</term>
<term>Nobel biocare</term>
<term>Oral maxillofac implants</term>
<term>Osstell mentor</term>
<term>Pilot drill</term>
<term>Present work</term>
<term>Primary stability</term>
<term>Resonance frequency</term>
<term>Resonance frequency analysis</term>
<term>Resonance frequency measurements</term>
<term>Roughness</term>
<term>Roughness parameters</term>
<term>Statistical analysis</term>
<term>Surface area</term>
<term>Surface morphology</term>
<term>Surface roughness</term>
<term>Surface treatment</term>
<term>Surface treatments</term>
<term>Surgical</term>
<term>Surgical protocol</term>
<term>Thread form</term>
<term>Thread geometry</term>
<term>Torque</term>
<term>Weight polyethylene</term>
</keywords>
<keywords scheme="Teeft" xml:lang="en"><term>Anodized</term>
<term>Bone density</term>
<term>Carlos nelson elias</term>
<term>Clinical implant dentistry</term>
<term>Conical</term>
<term>Conical implant</term>
<term>Contact area</term>
<term>Cortical bone</term>
<term>Cylindrical drill</term>
<term>Cylindrical implant</term>
<term>Cylindrical implants</term>
<term>Dental implant</term>
<term>Dental implants</term>
<term>Fastening screws</term>
<term>Greater roughness</term>
<term>Higher friction</term>
<term>Highest insertion torque</term>
<term>Hmwpe</term>
<term>Hmwpe cylinder</term>
<term>Hmwpe cylinders</term>
<term>Homogeneous material</term>
<term>Immediate loading</term>
<term>Implant</term>
<term>Implant design</term>
<term>Implant geometry</term>
<term>Implant insertion</term>
<term>Implant placement</term>
<term>Implant stability</term>
<term>Implant stability quotient</term>
<term>Implant stabilization</term>
<term>Implant surface</term>
<term>Implant surface morphology</term>
<term>Implant surface treatment</term>
<term>Implant surface treatments</term>
<term>Implant surfaces</term>
<term>Implant thread geometry</term>
<term>Insertion</term>
<term>Insertion torque</term>
<term>Insertion torque increases</term>
<term>Insertion torques</term>
<term>Instituto militar</term>
<term>Integration diagnostics</term>
<term>Larger insertion torque</term>
<term>Machined</term>
<term>Machined implants</term>
<term>Maxillofac</term>
<term>Maximum implant insertion torque</term>
<term>Mechanical properties</term>
<term>More parts</term>
<term>Morphology</term>
<term>Nishing</term>
<term>Nishing surface</term>
<term>Nobel biocare</term>
<term>Oral maxillofac implants</term>
<term>Osstell mentor</term>
<term>Pilot drill</term>
<term>Present work</term>
<term>Primary stability</term>
<term>Resonance frequency</term>
<term>Resonance frequency analysis</term>
<term>Resonance frequency measurements</term>
<term>Roughness</term>
<term>Roughness parameters</term>
<term>Statistical analysis</term>
<term>Surface area</term>
<term>Surface morphology</term>
<term>Surface roughness</term>
<term>Surface treatment</term>
<term>Surface treatments</term>
<term>Surgical</term>
<term>Surgical protocol</term>
<term>Thread form</term>
<term>Thread geometry</term>
<term>Torque</term>
<term>Weight polyethylene</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract">Background: Primary implant stability has been used as an indicator for future osseointegration and whether an immediate/early loading protocol should be applied. Implant stability is the key to clinical success.</div>
</front>
</TEI>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Main/Merge
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 004509 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Main/Merge/biblio.hfd -nk 004509 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Santé |area= EdenteV2 |flux= Main |étape= Merge |type= RBID |clé= ISTEX:FBBCB3694511D235E27CF4114620017CDA5D5D7D |texte= The Effects of Superficial Roughness and Design on the Primary Stability of Dental Implants }}
![]() | This area was generated with Dilib version V0.6.32. | ![]() |