Guided surgery: accuracy and efficacy
Identifieur interne : 001F42 ( Main/Exploration ); précédent : 001F41; suivant : 001F43Guided surgery: accuracy and efficacy
Auteurs : Marjolein Vercruyssen ; Margareta Hultin ; Nele Van Assche ; Krister Svensson ; Ignace Naert ; Marc QuirynenSource :
- Periodontology 2000 [ 0906-6713 ] ; 2014-10.
Abstract
Different computer‐assisted implant‐placement procedures are currently available. These differ in software, template manufacture, guiding device, stabilization and fixation. The literature seems to indicate that one has to accept a certain inaccuracy of ±2.0 mm, which seems large initially but is clearly smaller than for nonguided surgery. A reduction of accuracy to below 0.5 mm seems extremely difficult. A common shortcoming identified in the studies included in this review is inconsistency in how clinical data and outcome variables are reported. Another limitation is the small number of comparative clinical studies. In order to find the best guiding system or the most important parameters for optimal accuracy, more randomized clinical trials are necessary. Information on cost‐effectiveness and patient‐centered evaluations (i.e. questionnaires and interviews) must also be included.
Url:
DOI: 10.1111/prd.12046
Affiliations:
Links toward previous steps (curation, corpus...)
- to stream Istex, to step Corpus: 004F38
- to stream Istex, to step Curation: 004F38
- to stream Istex, to step Checkpoint: 000153
- to stream Main, to step Merge: 001F49
- to stream Main, to step Curation: 001F42
Le document en format XML
<record><TEI wicri:istexFullTextTei="biblStruct"><teiHeader><fileDesc><titleStmt><title xml:lang="en">Guided surgery: accuracy and efficacy</title>
<author><name sortKey="Vercruyssen, Marjolein" sort="Vercruyssen, Marjolein" uniqKey="Vercruyssen M" first="Marjolein" last="Vercruyssen">Marjolein Vercruyssen</name>
</author>
<author><name sortKey="Hultin, Margareta" sort="Hultin, Margareta" uniqKey="Hultin M" first="Margareta" last="Hultin">Margareta Hultin</name>
</author>
<author><name sortKey="Van Assche, Nele" sort="Van Assche, Nele" uniqKey="Van Assche N" first="Nele" last="Van Assche">Nele Van Assche</name>
</author>
<author><name sortKey="Svensson, Krister" sort="Svensson, Krister" uniqKey="Svensson K" first="Krister" last="Svensson">Krister Svensson</name>
</author>
<author><name sortKey="Naert, Ignace" sort="Naert, Ignace" uniqKey="Naert I" first="Ignace" last="Naert">Ignace Naert</name>
</author>
<author><name sortKey="Quirynen, Marc" sort="Quirynen, Marc" uniqKey="Quirynen M" first="Marc" last="Quirynen">Marc Quirynen</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:9EE3CC6B0C800830719B39779F4B4EBCF762145A</idno>
<date when="2014" year="2014">2014</date>
<idno type="doi">10.1111/prd.12046</idno>
<idno type="url">https://api.istex.fr/document/9EE3CC6B0C800830719B39779F4B4EBCF762145A/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">004F38</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Corpus" wicri:corpus="ISTEX">004F38</idno>
<idno type="wicri:Area/Istex/Curation">004F38</idno>
<idno type="wicri:Area/Istex/Checkpoint">000153</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Checkpoint">000153</idno>
<idno type="wicri:doubleKey">0906-6713:2014:Vercruyssen M:guided:surgery:accuracy</idno>
<idno type="wicri:Area/Main/Merge">001F49</idno>
<idno type="wicri:Area/Main/Curation">001F42</idno>
<idno type="wicri:Area/Main/Exploration">001F42</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title level="a" type="main">Guided surgery: accuracy and efficacy</title>
<author><name sortKey="Vercruyssen, Marjolein" sort="Vercruyssen, Marjolein" uniqKey="Vercruyssen M" first="Marjolein" last="Vercruyssen">Marjolein Vercruyssen</name>
</author>
<author><name sortKey="Hultin, Margareta" sort="Hultin, Margareta" uniqKey="Hultin M" first="Margareta" last="Hultin">Margareta Hultin</name>
</author>
<author><name sortKey="Van Assche, Nele" sort="Van Assche, Nele" uniqKey="Van Assche N" first="Nele" last="Van Assche">Nele Van Assche</name>
</author>
<author><name sortKey="Svensson, Krister" sort="Svensson, Krister" uniqKey="Svensson K" first="Krister" last="Svensson">Krister Svensson</name>
</author>
<author><name sortKey="Naert, Ignace" sort="Naert, Ignace" uniqKey="Naert I" first="Ignace" last="Naert">Ignace Naert</name>
</author>
<author><name sortKey="Quirynen, Marc" sort="Quirynen, Marc" uniqKey="Quirynen M" first="Marc" last="Quirynen">Marc Quirynen</name>
</author>
</analytic>
<monogr></monogr>
<series><title level="j" type="main">Periodontology 2000</title>
<title level="j" type="alt">PERIODONTOLOGY 2000</title>
<idno type="ISSN">0906-6713</idno>
<idno type="eISSN">1600-0757</idno>
<imprint><biblScope unit="vol">66</biblScope>
<biblScope unit="issue">1</biblScope>
<biblScope unit="page" from="228">228</biblScope>
<biblScope unit="page" to="246">246</biblScope>
<biblScope unit="page-count">19</biblScope>
<date type="published" when="2014-10">2014-10</date>
</imprint>
<idno type="ISSN">0906-6713</idno>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt><idno type="ISSN">0906-6713</idno>
</seriesStmt>
</fileDesc>
<profileDesc><textClass></textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract">Different computer‐assisted implant‐placement procedures are currently available. These differ in software, template manufacture, guiding device, stabilization and fixation. The literature seems to indicate that one has to accept a certain inaccuracy of ±2.0 mm, which seems large initially but is clearly smaller than for nonguided surgery. A reduction of accuracy to below 0.5 mm seems extremely difficult. A common shortcoming identified in the studies included in this review is inconsistency in how clinical data and outcome variables are reported. Another limitation is the small number of comparative clinical studies. In order to find the best guiding system or the most important parameters for optimal accuracy, more randomized clinical trials are necessary. Information on cost‐effectiveness and patient‐centered evaluations (i.e. questionnaires and interviews) must also be included.</div>
</front>
</TEI>
<affiliations><list></list>
<tree><noCountry><name sortKey="Hultin, Margareta" sort="Hultin, Margareta" uniqKey="Hultin M" first="Margareta" last="Hultin">Margareta Hultin</name>
<name sortKey="Naert, Ignace" sort="Naert, Ignace" uniqKey="Naert I" first="Ignace" last="Naert">Ignace Naert</name>
<name sortKey="Quirynen, Marc" sort="Quirynen, Marc" uniqKey="Quirynen M" first="Marc" last="Quirynen">Marc Quirynen</name>
<name sortKey="Svensson, Krister" sort="Svensson, Krister" uniqKey="Svensson K" first="Krister" last="Svensson">Krister Svensson</name>
<name sortKey="Van Assche, Nele" sort="Van Assche, Nele" uniqKey="Van Assche N" first="Nele" last="Van Assche">Nele Van Assche</name>
<name sortKey="Vercruyssen, Marjolein" sort="Vercruyssen, Marjolein" uniqKey="Vercruyssen M" first="Marjolein" last="Vercruyssen">Marjolein Vercruyssen</name>
</noCountry>
</tree>
</affiliations>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001F42 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 001F42 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Santé |area= EdenteV2 |flux= Main |étape= Exploration |type= RBID |clé= ISTEX:9EE3CC6B0C800830719B39779F4B4EBCF762145A |texte= Guided surgery: accuracy and efficacy }}
This area was generated with Dilib version V0.6.32. |