Quantification of bone quality using different cone beam computed tomography devices: Accuracy assessment for edentulous human mandibles.
Identifieur interne : 010F21 ( Main/Curation ); précédent : 010F20; suivant : 010F22Quantification of bone quality using different cone beam computed tomography devices: Accuracy assessment for edentulous human mandibles.
Auteurs : Jeroen Van Dessel ; Laura Ferreira Pinheiro Nicolielo ; Yan Huang ; Pieter Slagmolen ; Constantinus Politis ; Ivo Lambrichts ; Reinhilde JacobsSource :
- European journal of oral implantology [ 1756-2406 ]
Descripteurs français
- KwdFr :
- MESH :
- anatomie et histologie : Mandibule.
- imagerie diagnostique : Mandibule, Mâchoire édentée.
- instrumentation : Humains, Microtomographie aux rayons X, Tomodensitométrie à faisceau conique.
English descriptors
- KwdEn :
- MESH :
- anatomy & histology : Mandible.
- diagnostic imaging : Jaw, Edentulous, Mandible.
- instrumentation : Cone-Beam Computed Tomography.
- Humans, X-Ray Microtomography.
Abstract
To determine the accuracy of the latest cone beam computed tomography (CBCT) machines in comparison to multi-slice computer tomography (MSCT) and micro computed tomography (micro-CT) for objectively assessing trabecular and cortical bone quality prior to implant placement.
PubMed: 27990508
Links toward previous steps (curation, corpus...)
- to stream PubMed, to step Corpus: Pour aller vers cette notice dans l'étape Curation :000245
- to stream PubMed, to step Curation: Pour aller vers cette notice dans l'étape Curation :000245
- to stream PubMed, to step Checkpoint: Pour aller vers cette notice dans l'étape Curation :000245
- to stream Ncbi, to step Merge: Pour aller vers cette notice dans l'étape Curation :006C86
- to stream Ncbi, to step Curation: Pour aller vers cette notice dans l'étape Curation :006C86
- to stream Ncbi, to step Checkpoint: Pour aller vers cette notice dans l'étape Curation :006C86
- to stream Main, to step Merge: Pour aller vers cette notice dans l'étape Curation :011934
Links to Exploration step
pubmed:27990508Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">Quantification of bone quality using different cone beam computed tomography devices: Accuracy assessment for edentulous human mandibles.</title>
<author><name sortKey="Van Dessel, Jeroen" sort="Van Dessel, Jeroen" uniqKey="Van Dessel J" first="Jeroen" last="Van Dessel">Jeroen Van Dessel</name>
</author>
<author><name sortKey="Nicolielo, Laura Ferreira Pinheiro" sort="Nicolielo, Laura Ferreira Pinheiro" uniqKey="Nicolielo L" first="Laura Ferreira Pinheiro" last="Nicolielo">Laura Ferreira Pinheiro Nicolielo</name>
</author>
<author><name sortKey="Huang, Yan" sort="Huang, Yan" uniqKey="Huang Y" first="Yan" last="Huang">Yan Huang</name>
</author>
<author><name sortKey="Slagmolen, Pieter" sort="Slagmolen, Pieter" uniqKey="Slagmolen P" first="Pieter" last="Slagmolen">Pieter Slagmolen</name>
</author>
<author><name sortKey="Politis, Constantinus" sort="Politis, Constantinus" uniqKey="Politis C" first="Constantinus" last="Politis">Constantinus Politis</name>
</author>
<author><name sortKey="Lambrichts, Ivo" sort="Lambrichts, Ivo" uniqKey="Lambrichts I" first="Ivo" last="Lambrichts">Ivo Lambrichts</name>
</author>
<author><name sortKey="Jacobs, Reinhilde" sort="Jacobs, Reinhilde" uniqKey="Jacobs R" first="Reinhilde" last="Jacobs">Reinhilde Jacobs</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="????"><PubDate><MedlineDate>2016</MedlineDate>
</PubDate>
</date>
<idno type="RBID">pubmed:27990508</idno>
<idno type="pmid">27990508</idno>
<idno type="wicri:Area/PubMed/Corpus">000245</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">000245</idno>
<idno type="wicri:Area/PubMed/Curation">000245</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">000245</idno>
<idno type="wicri:Area/PubMed/Checkpoint">000245</idno>
<idno type="wicri:explorRef" wicri:stream="Checkpoint" wicri:step="PubMed">000245</idno>
<idno type="wicri:Area/Ncbi/Merge">006C86</idno>
<idno type="wicri:Area/Ncbi/Curation">006C86</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">006C86</idno>
<idno type="wicri:doubleKey">1756-2406::Van Dessel J:quantification:of:bone</idno>
<idno type="wicri:Area/Main/Merge">011934</idno>
<idno type="wicri:Area/Main/Curation">010F21</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">Quantification of bone quality using different cone beam computed tomography devices: Accuracy assessment for edentulous human mandibles.</title>
<author><name sortKey="Van Dessel, Jeroen" sort="Van Dessel, Jeroen" uniqKey="Van Dessel J" first="Jeroen" last="Van Dessel">Jeroen Van Dessel</name>
</author>
<author><name sortKey="Nicolielo, Laura Ferreira Pinheiro" sort="Nicolielo, Laura Ferreira Pinheiro" uniqKey="Nicolielo L" first="Laura Ferreira Pinheiro" last="Nicolielo">Laura Ferreira Pinheiro Nicolielo</name>
</author>
<author><name sortKey="Huang, Yan" sort="Huang, Yan" uniqKey="Huang Y" first="Yan" last="Huang">Yan Huang</name>
</author>
<author><name sortKey="Slagmolen, Pieter" sort="Slagmolen, Pieter" uniqKey="Slagmolen P" first="Pieter" last="Slagmolen">Pieter Slagmolen</name>
</author>
<author><name sortKey="Politis, Constantinus" sort="Politis, Constantinus" uniqKey="Politis C" first="Constantinus" last="Politis">Constantinus Politis</name>
</author>
<author><name sortKey="Lambrichts, Ivo" sort="Lambrichts, Ivo" uniqKey="Lambrichts I" first="Ivo" last="Lambrichts">Ivo Lambrichts</name>
</author>
<author><name sortKey="Jacobs, Reinhilde" sort="Jacobs, Reinhilde" uniqKey="Jacobs R" first="Reinhilde" last="Jacobs">Reinhilde Jacobs</name>
</author>
</analytic>
<series><title level="j">European journal of oral implantology</title>
<idno type="ISSN">1756-2406</idno>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Cone-Beam Computed Tomography (instrumentation)</term>
<term>Humans</term>
<term>Jaw, Edentulous (diagnostic imaging)</term>
<term>Mandible (anatomy & histology)</term>
<term>Mandible (diagnostic imaging)</term>
<term>X-Ray Microtomography</term>
</keywords>
<keywords scheme="KwdFr" xml:lang="fr"><term>Humains</term>
<term>Mandibule (anatomie et histologie)</term>
<term>Mandibule (imagerie diagnostique)</term>
<term>Microtomographie aux rayons X</term>
<term>Mâchoire édentée (imagerie diagnostique)</term>
<term>Tomodensitométrie à faisceau conique (instrumentation)</term>
</keywords>
<keywords scheme="MESH" qualifier="anatomie et histologie" xml:lang="fr"><term>Mandibule</term>
</keywords>
<keywords scheme="MESH" qualifier="anatomy & histology" xml:lang="en"><term>Mandible</term>
</keywords>
<keywords scheme="MESH" qualifier="diagnostic imaging" xml:lang="en"><term>Jaw, Edentulous</term>
<term>Mandible</term>
</keywords>
<keywords scheme="MESH" qualifier="imagerie diagnostique" xml:lang="fr"><term>Mandibule</term>
<term>Mâchoire édentée</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en"><term>Cone-Beam Computed Tomography</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Humans</term>
<term>X-Ray Microtomography</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="fr"><term>Humains</term>
<term>Microtomographie aux rayons X</term>
<term>Tomodensitométrie à faisceau conique</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">To determine the accuracy of the latest cone beam computed tomography (CBCT) machines in comparison to multi-slice computer tomography (MSCT) and micro computed tomography (micro-CT) for objectively assessing trabecular and cortical bone quality prior to implant placement.</div>
</front>
</TEI>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Main/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 010F21 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Main/Curation/biblio.hfd -nk 010F21 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Santé |area= EdenteV2 |flux= Main |étape= Curation |type= RBID |clé= pubmed:27990508 |texte= Quantification of bone quality using different cone beam computed tomography devices: Accuracy assessment for edentulous human mandibles. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Curation/RBID.i -Sk "pubmed:27990508" \ | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Curation/biblio.hfd \ | NlmPubMed2Wicri -a EdenteV2
This area was generated with Dilib version V0.6.32. |