Quantification of bone quality using different cone beam computed tomography devices: Accuracy assessment for edentulous human mandibles.

Identifieur interne : 000245 ( PubMed/Curation ); précédent : 000244; suivant : 000246

Quantification of bone quality using different cone beam computed tomography devices: Accuracy assessment for edentulous human mandibles.

Auteurs : Jeroen Van Dessel ; Laura Ferreira Pinheiro Nicolielo ; Yan Huang ; Pieter Slagmolen ; Constantinus Politis ; Ivo Lambrichts ; Reinhilde Jacobs

Source :

RBID : pubmed:27990508

Descripteurs français

English descriptors

Abstract

To determine the accuracy of the latest cone beam computed tomography (CBCT) machines in comparison to multi-slice computer tomography (MSCT) and micro computed tomography (micro-CT) for objectively assessing trabecular and cortical bone quality prior to implant placement.

PubMed: 27990508

Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:27990508

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Quantification of bone quality using different cone beam computed tomography devices: Accuracy assessment for edentulous human mandibles.</title>
<author>
<name sortKey="Van Dessel, Jeroen" sort="Van Dessel, Jeroen" uniqKey="Van Dessel J" first="Jeroen" last="Van Dessel">Jeroen Van Dessel</name>
</author>
<author>
<name sortKey="Nicolielo, Laura Ferreira Pinheiro" sort="Nicolielo, Laura Ferreira Pinheiro" uniqKey="Nicolielo L" first="Laura Ferreira Pinheiro" last="Nicolielo">Laura Ferreira Pinheiro Nicolielo</name>
</author>
<author>
<name sortKey="Huang, Yan" sort="Huang, Yan" uniqKey="Huang Y" first="Yan" last="Huang">Yan Huang</name>
</author>
<author>
<name sortKey="Slagmolen, Pieter" sort="Slagmolen, Pieter" uniqKey="Slagmolen P" first="Pieter" last="Slagmolen">Pieter Slagmolen</name>
</author>
<author>
<name sortKey="Politis, Constantinus" sort="Politis, Constantinus" uniqKey="Politis C" first="Constantinus" last="Politis">Constantinus Politis</name>
</author>
<author>
<name sortKey="Lambrichts, Ivo" sort="Lambrichts, Ivo" uniqKey="Lambrichts I" first="Ivo" last="Lambrichts">Ivo Lambrichts</name>
</author>
<author>
<name sortKey="Jacobs, Reinhilde" sort="Jacobs, Reinhilde" uniqKey="Jacobs R" first="Reinhilde" last="Jacobs">Reinhilde Jacobs</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="????">
<PubDate>
<MedlineDate>2016</MedlineDate>
</PubDate>
</date>
<idno type="RBID">pubmed:27990508</idno>
<idno type="pmid">27990508</idno>
<idno type="wicri:Area/PubMed/Corpus">000245</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">000245</idno>
<idno type="wicri:Area/PubMed/Curation">000245</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">000245</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Quantification of bone quality using different cone beam computed tomography devices: Accuracy assessment for edentulous human mandibles.</title>
<author>
<name sortKey="Van Dessel, Jeroen" sort="Van Dessel, Jeroen" uniqKey="Van Dessel J" first="Jeroen" last="Van Dessel">Jeroen Van Dessel</name>
</author>
<author>
<name sortKey="Nicolielo, Laura Ferreira Pinheiro" sort="Nicolielo, Laura Ferreira Pinheiro" uniqKey="Nicolielo L" first="Laura Ferreira Pinheiro" last="Nicolielo">Laura Ferreira Pinheiro Nicolielo</name>
</author>
<author>
<name sortKey="Huang, Yan" sort="Huang, Yan" uniqKey="Huang Y" first="Yan" last="Huang">Yan Huang</name>
</author>
<author>
<name sortKey="Slagmolen, Pieter" sort="Slagmolen, Pieter" uniqKey="Slagmolen P" first="Pieter" last="Slagmolen">Pieter Slagmolen</name>
</author>
<author>
<name sortKey="Politis, Constantinus" sort="Politis, Constantinus" uniqKey="Politis C" first="Constantinus" last="Politis">Constantinus Politis</name>
</author>
<author>
<name sortKey="Lambrichts, Ivo" sort="Lambrichts, Ivo" uniqKey="Lambrichts I" first="Ivo" last="Lambrichts">Ivo Lambrichts</name>
</author>
<author>
<name sortKey="Jacobs, Reinhilde" sort="Jacobs, Reinhilde" uniqKey="Jacobs R" first="Reinhilde" last="Jacobs">Reinhilde Jacobs</name>
</author>
</analytic>
<series>
<title level="j">European journal of oral implantology</title>
<idno type="ISSN">1756-2406</idno>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Cone-Beam Computed Tomography (instrumentation)</term>
<term>Humans</term>
<term>Jaw, Edentulous (diagnostic imaging)</term>
<term>Mandible (anatomy & histology)</term>
<term>Mandible (diagnostic imaging)</term>
<term>X-Ray Microtomography</term>
</keywords>
<keywords scheme="KwdFr" xml:lang="fr">
<term>Humains</term>
<term>Mandibule (anatomie et histologie)</term>
<term>Mandibule (imagerie diagnostique)</term>
<term>Microtomographie aux rayons X</term>
<term>Mâchoire édentée (imagerie diagnostique)</term>
<term>Tomodensitométrie à faisceau conique (instrumentation)</term>
</keywords>
<keywords scheme="MESH" qualifier="anatomie et histologie" xml:lang="fr">
<term>Mandibule</term>
</keywords>
<keywords scheme="MESH" qualifier="anatomy & histology" xml:lang="en">
<term>Mandible</term>
</keywords>
<keywords scheme="MESH" qualifier="diagnostic imaging" xml:lang="en">
<term>Jaw, Edentulous</term>
<term>Mandible</term>
</keywords>
<keywords scheme="MESH" qualifier="imagerie diagnostique" xml:lang="fr">
<term>Mandibule</term>
<term>Mâchoire édentée</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en">
<term>Cone-Beam Computed Tomography</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Humans</term>
<term>X-Ray Microtomography</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="fr">
<term>Humains</term>
<term>Microtomographie aux rayons X</term>
<term>Tomodensitométrie à faisceau conique</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">To determine the accuracy of the latest cone beam computed tomography (CBCT) machines in comparison to multi-slice computer tomography (MSCT) and micro computed tomography (micro-CT) for objectively assessing trabecular and cortical bone quality prior to implant placement.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Status="MEDLINE" Owner="NLM">
<PMID Version="1">27990508</PMID>
<DateCompleted>
<Year>2017</Year>
<Month>08</Month>
<Day>03</Day>
</DateCompleted>
<DateRevised>
<Year>2017</Year>
<Month>08</Month>
<Day>03</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">1756-2406</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>9</Volume>
<Issue>4</Issue>
<PubDate>
<MedlineDate>2016</MedlineDate>
</PubDate>
</JournalIssue>
<Title>European journal of oral implantology</Title>
<ISOAbbreviation>Eur J Oral Implantol</ISOAbbreviation>
</Journal>
<ArticleTitle>Quantification of bone quality using different cone beam computed tomography devices: Accuracy assessment for edentulous human mandibles.</ArticleTitle>
<Pagination>
<MedlinePgn>411-424</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText Label="PURPOSE" NlmCategory="OBJECTIVE">To determine the accuracy of the latest cone beam computed tomography (CBCT) machines in comparison to multi-slice computer tomography (MSCT) and micro computed tomography (micro-CT) for objectively assessing trabecular and cortical bone quality prior to implant placement.</AbstractText>
<AbstractText Label="MATERIALS AND METHODS" NlmCategory="METHODS">Eight edentulous human mandibular bone samples were scanned with seven CBCT scanners (3D Accuitomo 170, i-CAT Next Generation, ProMax 3D Max, Scanora 3D, Cranex 3D, Newtom GiANO and Carestream 9300) and one MSCT system (Somatom Definition Flash) using the clinical exposure protocol with the highest resolution. Micro-CT (SkyScan 1174) images served as a gold standard. A volume of interest (VOI) comprising trabecular and cortical bone only was delineated on the micro-CT. After spatial alignment of all scan types, micro-CT VOIs were overlaid on the CBCT and MSCT images. Segmentation was applied and morphometric parameters were calculated for each scanner. CBCT and MSCT morphometric parameters were compared with micro-CT using mixed-effect models. Intraclass correlation analysis was used to grade the accuracy of each scanner in assessing trabecular and cortical quality in comparison with the gold standard. Bone structure patterns of each scanner were compared with micro-CT in 2D and 3D to facilitate the interpretation of the morphometric analysis.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">Morphometric analysis showed an overestimation of the cortical and trabecular bone quantity during CBCT and MSCT evaluation compared to the gold standard micro-CT. The trabecular thickness (Tb.Th) was found to be significantly (P < 0.05) different and the smallest overestimation was found for the ProMax 3D Max (180 µm), followed by the 3D Accuitomo 170 (200 µm), Carestream 9300 (220 µm), Newtom GiANO (240 µm), Cranex 3D (280 µm), Scanora 3D (300 µm), high resolution MSCT (310 µm), i-CAT Next Generation (430 µm) and standard resolution MSCT (510 µm). The underestimation of the cortical thickness (Ct.Th) in ProMax 3D Max (-10 µm), the overestimation in Newtom GiANO (10 µm) and the high resolution MSCT (10 µm) were neglible. However, a significant overestimation (P < 0.05) was found for 3D Accuitomo 170 (110 µm), Scanora 3D (140 µm), standard resolution MSCT (150 µm), Carestream 9300 (190 µm), Cranex 3D (190 µm) and i-CAT Next Generation (230 µm). Comparison of the 2D network and 3D surface distance confirmed the overestimation in bone quantity, but only demonstrated a deviant trabecular network for the i-CAT Next Generation and the standard resolution MSCT. Intraclass correlation coefficients (ICCs) showed a significant (P < 0.05) high intra-observer reliability (ICC > 0.70) in morphometric evaluation between micro-CT and commercially available CBCT scanners (3D Accuitomo 170, Newtom GiANO and ProMax 3D Max). The ICC for Tb.Th and Ct.Th were 0.72 and 0.98 (3D Accuitomo 170), 0.71 and 0.96 (Newtom GiANO), and 0.87 and 0.92 (ProMax 3D Max), respectively.</AbstractText>
<AbstractText Label="CONCLUSIONS" NlmCategory="CONCLUSIONS">High resolution CBCT offers a clinical alternative to MSCT to objectively determine the bone quality prior to implant placement. However, not all tested CBCT machines have sufficient resolution to accurately depict the trabecular network or cortical bone. Conflict-of-interest statement: There is no conflict of interest to declare.</AbstractText>
<AbstractText Label="FUNDING" NlmCategory="BACKGROUND">Fellowship support came from Research Foundation Flanders (FWO) from the Belgian government, and Coordination for the Improvement of Higher Education Personnel (CAPES) program and Science without borders from the Brazilian government.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Van Dessel</LastName>
<ForeName>Jeroen</ForeName>
<Initials>J</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Nicolielo</LastName>
<ForeName>Laura Ferreira Pinheiro</ForeName>
<Initials>LF</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Huang</LastName>
<ForeName>Yan</ForeName>
<Initials>Y</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Slagmolen</LastName>
<ForeName>Pieter</ForeName>
<Initials>P</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Politis</LastName>
<ForeName>Constantinus</ForeName>
<Initials>C</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Lambrichts</LastName>
<ForeName>Ivo</ForeName>
<Initials>I</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Jacobs</LastName>
<ForeName>Reinhilde</ForeName>
<Initials>R</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>England</Country>
<MedlineTA>Eur J Oral Implantol</MedlineTA>
<NlmUniqueID>101473719</NlmUniqueID>
<ISSNLinking>1756-2406</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>D</CitationSubset>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName UI="D054893" MajorTopicYN="Y">Cone-Beam Computed Tomography</DescriptorName>
<QualifierName UI="Q000295" MajorTopicYN="N">instrumentation</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D007575" MajorTopicYN="N">Jaw, Edentulous</DescriptorName>
<QualifierName UI="Q000000981" MajorTopicYN="Y">diagnostic imaging</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008334" MajorTopicYN="N">Mandible</DescriptorName>
<QualifierName UI="Q000033" MajorTopicYN="N">anatomy & histology</QualifierName>
<QualifierName UI="Q000000981" MajorTopicYN="N">diagnostic imaging</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D055114" MajorTopicYN="Y">X-Ray Microtomography</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="entrez">
<Year>2016</Year>
<Month>12</Month>
<Day>20</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2016</Year>
<Month>12</Month>
<Day>19</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2017</Year>
<Month>8</Month>
<Day>5</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">27990508</ArticleId>
<ArticleId IdType="pii">37403</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/PubMed/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000245 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd -nk 000245 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    PubMed
   |étape=   Curation
   |type=    RBID
   |clé=     pubmed:27990508
   |texte=   Quantification of bone quality using different cone beam computed tomography devices: Accuracy assessment for edentulous human mandibles.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Curation/RBID.i   -Sk "pubmed:27990508" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV2 

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022