Abstract

To assess and compare the papilla presence mesially and distally to dental implants restored with customized abutments and custom metal abutments in the anterior maxilla.

Url:
DOI: 10.1111/clr.12257

Links to Exploration step

ISTEX:7F9C67B6183AA42AE75D13C08AFD2976B6D75B13

Le document en format XML

<record>
<TEI wicri:istexFullTextTei="biblStruct">
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">The influence of customized abutments and custom metal abutments on the presence of the interproximal papilla at implants inserted in single‐unit gaps: a 1‐year prospective clinical study</title>
<author>
<name sortKey="Borges, Tiago" sort="Borges, Tiago" uniqKey="Borges T" first="Tiago" last="Borges">Tiago Borges</name>
<affiliation>
<mods:affiliation>Department of Oral Surgery and Implant Dentistry, Portuguese Catholic University, Viseu, Portugal</mods:affiliation>
</affiliation>
<affiliation>
<mods:affiliation>Department of Oral Surgery and Implant DentistryBragança Private Medical CentreRua João XXI, 59/60, R/Ch Esq., 5300‐435 Bragança, PortugalTel.: +00351 917411447Fax: +00351 273328639e‐mail:</mods:affiliation>
</affiliation>
<affiliation>
<mods:affiliation>E-mail: geral@cmeb.pt</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Lima, Tiago" sort="Lima, Tiago" uniqKey="Lima T" first="Tiago" last="Lima">Tiago Lima</name>
<affiliation>
<mods:affiliation>Department of Oral Surgery and Implant Dentistry, Bragança Private Medical Centre, Bragança, Portugal</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Carvalho, Agata" sort="Carvalho, Agata" uniqKey="Carvalho A" first="Ágata" last="Carvalho">Ágata Carvalho</name>
<affiliation>
<mods:affiliation>Department of Oral Surgery and Implant Dentistry, Bragança Private Medical Centre, Bragança, Portugal</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Dourado, Catarina" sort="Dourado, Catarina" uniqKey="Dourado C" first="Catarina" last="Dourado">Catarina Dourado</name>
<affiliation>
<mods:affiliation>Chaves Private Medical Centre, Chaves, Portugal</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Carvalho, Vasco" sort="Carvalho, Vasco" uniqKey="Carvalho V" first="Vasco" last="Carvalho">Vasco Carvalho</name>
<affiliation>
<mods:affiliation>Chaves Private Medical Centre, Chaves, Portugal</mods:affiliation>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:7F9C67B6183AA42AE75D13C08AFD2976B6D75B13</idno>
<date when="2014" year="2014">2014</date>
<idno type="doi">10.1111/clr.12257</idno>
<idno type="url">https://api.istex.fr/document/7F9C67B6183AA42AE75D13C08AFD2976B6D75B13/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">003F27</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Corpus" wicri:corpus="ISTEX">003F27</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title level="a" type="main">The influence of customized abutments and custom metal abutments on the presence of the interproximal papilla at implants inserted in single‐unit gaps: a 1‐year prospective clinical study</title>
<author>
<name sortKey="Borges, Tiago" sort="Borges, Tiago" uniqKey="Borges T" first="Tiago" last="Borges">Tiago Borges</name>
<affiliation>
<mods:affiliation>Department of Oral Surgery and Implant Dentistry, Portuguese Catholic University, Viseu, Portugal</mods:affiliation>
</affiliation>
<affiliation>
<mods:affiliation>Department of Oral Surgery and Implant DentistryBragança Private Medical CentreRua João XXI, 59/60, R/Ch Esq., 5300‐435 Bragança, PortugalTel.: +00351 917411447Fax: +00351 273328639e‐mail:</mods:affiliation>
</affiliation>
<affiliation>
<mods:affiliation>E-mail: geral@cmeb.pt</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Lima, Tiago" sort="Lima, Tiago" uniqKey="Lima T" first="Tiago" last="Lima">Tiago Lima</name>
<affiliation>
<mods:affiliation>Department of Oral Surgery and Implant Dentistry, Bragança Private Medical Centre, Bragança, Portugal</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Carvalho, Agata" sort="Carvalho, Agata" uniqKey="Carvalho A" first="Ágata" last="Carvalho">Ágata Carvalho</name>
<affiliation>
<mods:affiliation>Department of Oral Surgery and Implant Dentistry, Bragança Private Medical Centre, Bragança, Portugal</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Dourado, Catarina" sort="Dourado, Catarina" uniqKey="Dourado C" first="Catarina" last="Dourado">Catarina Dourado</name>
<affiliation>
<mods:affiliation>Chaves Private Medical Centre, Chaves, Portugal</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Carvalho, Vasco" sort="Carvalho, Vasco" uniqKey="Carvalho V" first="Vasco" last="Carvalho">Vasco Carvalho</name>
<affiliation>
<mods:affiliation>Chaves Private Medical Centre, Chaves, Portugal</mods:affiliation>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series>
<title level="j" type="main">Clinical Oral Implants Research</title>
<title level="j" type="alt">CLINICAL ORAL IMPLANTS RESEARCH</title>
<idno type="ISSN">0905-7161</idno>
<idno type="eISSN">1600-0501</idno>
<imprint>
<biblScope unit="vol">25</biblScope>
<biblScope unit="issue">11</biblScope>
<biblScope unit="page" from="1222">1222</biblScope>
<biblScope unit="page" to="1227">1227</biblScope>
<biblScope unit="page-count">6</biblScope>
<date type="published" when="2014-11">2014-11</date>
</imprint>
<idno type="ISSN">0905-7161</idno>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt>
<idno type="ISSN">0905-7161</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract">To assess and compare the papilla presence mesially and distally to dental implants restored with customized abutments and custom metal abutments in the anterior maxilla.</div>
</front>
</TEI>
<istex>
<corpusName>wiley</corpusName>
<author>
<json:item>
<name>Tiago Borges</name>
<affiliations>
<json:string>Department of Oral Surgery and Implant Dentistry, Portuguese Catholic University, Viseu, Portugal</json:string>
<json:string>Department of Oral Surgery and Implant DentistryBragança Private Medical CentreRua João XXI, 59/60, R/Ch Esq., 5300‐435 Bragança, PortugalTel.: +00351 917411447Fax: +00351 273328639e‐mail:</json:string>
<json:string>E-mail: geral@cmeb.pt</json:string>
</affiliations>
</json:item>
<json:item>
<name>Tiago Lima</name>
<affiliations>
<json:string>Department of Oral Surgery and Implant Dentistry, Bragança Private Medical Centre, Bragança, Portugal</json:string>
</affiliations>
</json:item>
<json:item>
<name>Ágata Carvalho</name>
<affiliations>
<json:string>Department of Oral Surgery and Implant Dentistry, Bragança Private Medical Centre, Bragança, Portugal</json:string>
</affiliations>
</json:item>
<json:item>
<name>Catarina Dourado</name>
<affiliations>
<json:string>Chaves Private Medical Centre, Chaves, Portugal</json:string>
</affiliations>
</json:item>
<json:item>
<name>Vasco Carvalho</name>
<affiliations>
<json:string>Chaves Private Medical Centre, Chaves, Portugal</json:string>
</affiliations>
</json:item>
</author>
<subject>
<json:item>
<lang>
<json:string>eng</json:string>
</lang>
<value>computer‐assisted design</value>
</json:item>
<json:item>
<lang>
<json:string>eng</json:string>
</lang>
<value>computer‐assisted manufacturing</value>
</json:item>
<json:item>
<lang>
<json:string>eng</json:string>
</lang>
<value>implant abutments</value>
</json:item>
<json:item>
<lang>
<json:string>eng</json:string>
</lang>
<value>interproximal papilla</value>
</json:item>
<json:item>
<lang>
<json:string>eng</json:string>
</lang>
<value>outcomes assessment</value>
</json:item>
</subject>
<articleId>
<json:string>CLR12257</json:string>
</articleId>
<arkIstex>ark:/67375/WNG-TW2PP1CS-1</arkIstex>
<language>
<json:string>eng</json:string>
</language>
<originalGenre>
<json:string>article</json:string>
</originalGenre>
<abstract>To assess and compare the papilla presence mesially and distally to dental implants restored with customized abutments and custom metal abutments in the anterior maxilla.</abstract>
<qualityIndicators>
<score>6.172</score>
<pdfWordCount>3872</pdfWordCount>
<pdfCharCount>26682</pdfCharCount>
<pdfVersion>1.6</pdfVersion>
<pdfPageCount>6</pdfPageCount>
<pdfPageSize>595.276 x 782.362 pts</pdfPageSize>
<refBibsNative>true</refBibsNative>
<abstractWordCount>25</abstractWordCount>
<abstractCharCount>170</abstractCharCount>
<keywordCount>5</keywordCount>
</qualityIndicators>
<title>The influence of customized abutments and custom metal abutments on the presence of the interproximal papilla at implants inserted in single‐unit gaps: a 1‐year prospective clinical study</title>
<genre>
<json:string>article</json:string>
</genre>
<host>
<title>Clinical Oral Implants Research</title>
<language>
<json:string>unknown</json:string>
</language>
<doi>
<json:string>10.1111/(ISSN)1600-0501</json:string>
</doi>
<issn>
<json:string>0905-7161</json:string>
</issn>
<eissn>
<json:string>1600-0501</json:string>
</eissn>
<publisherId>
<json:string>CLR</json:string>
</publisherId>
<volume>25</volume>
<issue>11</issue>
<pages>
<first>1222</first>
<last>1227</last>
<total>6</total>
</pages>
<genre>
<json:string>journal</json:string>
</genre>
<subject>
<json:item>
<value>Original Article</value>
</json:item>
</subject>
</host>
<ark>
<json:string>ark:/67375/WNG-TW2PP1CS-1</json:string>
</ark>
<publicationDate>2014</publicationDate>
<copyrightDate>2014</copyrightDate>
<doi>
<json:string>10.1111/clr.12257</json:string>
</doi>
<id>7F9C67B6183AA42AE75D13C08AFD2976B6D75B13</id>
<score>1</score>
<fulltext>
<json:item>
<extension>pdf</extension>
<original>true</original>
<mimetype>application/pdf</mimetype>
<uri>https://api.istex.fr/document/7F9C67B6183AA42AE75D13C08AFD2976B6D75B13/fulltext/pdf</uri>
</json:item>
<json:item>
<extension>zip</extension>
<original>false</original>
<mimetype>application/zip</mimetype>
<uri>https://api.istex.fr/document/7F9C67B6183AA42AE75D13C08AFD2976B6D75B13/fulltext/zip</uri>
</json:item>
<istex:fulltextTEI uri="https://api.istex.fr/document/7F9C67B6183AA42AE75D13C08AFD2976B6D75B13/fulltext/tei">
<teiHeader>
<fileDesc>
<titleStmt>
<title level="a" type="main">The influence of customized abutments and custom metal abutments on the presence of the interproximal papilla at implants inserted in single‐unit gaps: a 1‐year prospective clinical study</title>
</titleStmt>
<publicationStmt>
<authority>ISTEX</authority>
<publisher>Wiley Publishing Ltd</publisher>
<availability>
<licence>© 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd</licence>
</availability>
<date type="published" when="2014-11"></date>
</publicationStmt>
<notesStmt>
<note type="content-type" subtype="article" source="article" scheme="https://content-type.data.istex.fr/ark:/67375/XTP-6N5SZHKN-D">article</note>
<note type="publication-type" subtype="journal" scheme="https://publication-type.data.istex.fr/ark:/67375/JMC-0GLKJH51-B">journal</note>
</notesStmt>
<sourceDesc>
<biblStruct type="article">
<analytic>
<title level="a" type="main">The influence of customized abutments and custom metal abutments on the presence of the interproximal papilla at implants inserted in single‐unit gaps: a 1‐year prospective clinical study</title>
<author xml:id="author-0000" role="corresp">
<persName>
<forename type="first">Tiago</forename>
<surname>Borges</surname>
</persName>
<affiliation>
<orgName>Department of Oral Surgery and Implant Dentistry</orgName>
<orgName>Portuguese Catholic University</orgName>
<address>
<settlement type="city">Viseu</settlement>
<country key="PT">Portugal</country>
</address>
</affiliation>
<affiliation>Corresponding author: Assist. Prof. Tiago Borges Department of Oral Surgery and Implant Dentistry Bragança Private Medical Centre Rua João XXI, 59/60, R/Ch Esq., 5300‐435 Bragança, Portugal Tel.: +00351 917411447 Fax: +00351 273328639 e‐mail: geral@cmeb.pt</affiliation>
</author>
<author xml:id="author-0001">
<persName>
<forename type="first">Tiago</forename>
<surname>Lima</surname>
</persName>
<affiliation>
<orgName>Department of Oral Surgery and Implant Dentistry</orgName>
<orgName>Bragança Private Medical Centre</orgName>
<address>
<settlement type="city">Bragança</settlement>
<country key="PT">Portugal</country>
</address>
</affiliation>
</author>
<author xml:id="author-0002">
<persName>
<forename type="first">Ágata</forename>
<surname>Carvalho</surname>
</persName>
<affiliation>
<orgName>Department of Oral Surgery and Implant Dentistry</orgName>
<orgName>Bragança Private Medical Centre</orgName>
<address>
<settlement type="city">Bragança</settlement>
<country key="PT">Portugal</country>
</address>
</affiliation>
</author>
<author xml:id="author-0003">
<persName>
<forename type="first">Catarina</forename>
<surname>Dourado</surname>
</persName>
<affiliation>
<orgName>Chaves Private Medical Centre</orgName>
<address>
<settlement type="city">Chaves</settlement>
<country key="PT">Portugal</country>
</address>
</affiliation>
</author>
<author xml:id="author-0004">
<persName>
<forename type="first">Vasco</forename>
<surname>Carvalho</surname>
</persName>
<affiliation>
<orgName>Chaves Private Medical Centre</orgName>
<address>
<settlement type="city">Chaves</settlement>
<country key="PT">Portugal</country>
</address>
</affiliation>
</author>
<idno type="istex">7F9C67B6183AA42AE75D13C08AFD2976B6D75B13</idno>
<idno type="ark">ark:/67375/WNG-TW2PP1CS-1</idno>
<idno type="DOI">10.1111/clr.12257</idno>
<idno type="unit">CLR12257</idno>
<idno type="toTypesetVersion">file:CLR.CLR12257.pdf</idno>
</analytic>
<monogr>
<title level="j" type="main">Clinical Oral Implants Research</title>
<title level="j" type="alt">CLINICAL ORAL IMPLANTS RESEARCH</title>
<idno type="pISSN">0905-7161</idno>
<idno type="eISSN">1600-0501</idno>
<idno type="book-DOI">10.1111/(ISSN)1600-0501</idno>
<idno type="book-part-DOI">10.1111/clr.2014.25.issue-11</idno>
<idno type="product">CLR</idno>
<imprint>
<biblScope unit="vol">25</biblScope>
<biblScope unit="issue">11</biblScope>
<biblScope unit="page" from="1222">1222</biblScope>
<biblScope unit="page" to="1227">1227</biblScope>
<biblScope unit="page-count">6</biblScope>
<date type="published" when="2014-11"></date>
</imprint>
</monogr>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<abstract style="main" xml:id="clr12257-abs-0001">
<head>Abstract</head>
Objectives
<p>To assess and compare the papilla presence mesially and distally to dental implants restored with customized abutments and custom metal abutments in the anterior maxilla.</p>
Material and methods
<p>Thirty‐eight patients receiving 38 single‐tooth implants, restored with 26 customized abutments and 12 custom metal abutments in the anterior maxillary region were enrolled in this study. The cases where did not existed contact point were excluded. Presence/absence of the interproximal papilla, inter‐tooth–implant distance (
<hi rend="fc">ITD</hi>
) and distance from the base of the contact point to dental crest bone of adjacent tooth (
<hi rend="fc">CPB</hi>
) were accessed. Global
<hi rend="italic">P</hi>
‐values were determined for changes in
<hi rend="fc">CPB</hi>
and papilla score over time (
<hi rend="italic"></hi>
<
<hi rend="italic"> </hi>
0.05).</p>
Results
<p>Thirty‐six patients with 36 implants were available for the 12‐month follow‐up. The abutments and reconstruction survival rate was 100% with no fracture or crown loss. A mean mesial
<hi rend="fc">CPB</hi>
of 5.71 ± 1.54 mm and distal
<hi rend="fc">CPB</hi>
of 4.01 ± 1.73 mm were assessed in the customized abutment group for an overall mean papilla presence of 1.69 ± 0.46. A mean mesial
<hi rend="fc">CPB</hi>
of 5.41 ± 1.31 mm and distal
<hi rend="fc">CPB</hi>
of 4.77 ± 1.21 mm were assessed in the control group for an overall mean papilla presence of 1.08 ± 0.65.</p>
Conclusions
<p>The restoration of single‐implants using computer‐assisted design/computer‐assisted manufacturing abutments appears to help maintaining a regular papillary filling although the variations of the implant positioning or the restoration/teeth relation.</p>
</abstract>
<textClass>
<keywords>
<term xml:id="clr12257-kwd-0001">computer‐assisted design</term>
<term xml:id="clr12257-kwd-0002">computer‐assisted manufacturing</term>
<term xml:id="clr12257-kwd-0003">implant abutments</term>
<term xml:id="clr12257-kwd-0004">interproximal papilla</term>
<term xml:id="clr12257-kwd-0005">outcomes assessment</term>
</keywords>
<keywords rend="articleCategory">
<term>Original Article</term>
</keywords>
<keywords rend="tocHeading1">
<term>Original Articles</term>
</keywords>
</textClass>
<langUsage>
<language ident="en"></language>
</langUsage>
</profileDesc>
</teiHeader>
</istex:fulltextTEI>
</fulltext>
<metadata>
<istex:metadataXml wicri:clean="Wiley, elements deleted: body">
<istex:xmlDeclaration>version="1.0" encoding="UTF-8" standalone="yes"</istex:xmlDeclaration>
<istex:document>
<component type="serialArticle" version="2.0" xml:id="clr12257" xml:lang="en">
<header>
<publicationMeta level="product">
<doi origin="wiley" registered="yes">10.1111/(ISSN)1600-0501</doi>
<issn type="print">0905-7161</issn>
<issn type="electronic">1600-0501</issn>
<idGroup>
<id type="product" value="CLR"></id>
</idGroup>
<titleGroup>
<title sort="CLINICAL ORAL IMPLANTS RESEARCH" type="main">Clinical Oral Implants Research</title>
<title type="short">Clin. Oral Impl. Res.</title>
</titleGroup>
</publicationMeta>
<publicationMeta level="part" position="110">
<doi origin="wiley">10.1111/clr.2014.25.issue-11</doi>
<copyright ownership="publisher">Copyright © 2014 John Wiley & Sons Ltd</copyright>
<numberingGroup>
<numbering type="journalVolume" number="25">25</numbering>
<numbering type="journalIssue">11</numbering>
</numberingGroup>
<coverDate startDate="2014-11">November 2014</coverDate>
</publicationMeta>
<publicationMeta level="unit" position="20" status="forIssue" type="article">
<doi>10.1111/clr.12257</doi>
<idGroup>
<id type="unit" value="CLR12257"></id>
</idGroup>
<countGroup>
<count number="6" type="pageTotal"></count>
</countGroup>
<titleGroup>
<title type="articleCategory">Original Article</title>
<title type="tocHeading1">Original Articles</title>
</titleGroup>
<copyright ownership="publisher">© 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd</copyright>
<eventGroup>
<event date="2013-08-04" type="manuscriptAccepted"></event>
<event agent="SPS" date="2013-08-19" type="xmlCreated"></event>
<event type="xmlConverted" agent="Converter:WILEY_ML3G_TO_WILEY_ML3GV2 version:3.3.5 mode:FullText" date="2014-10-03"></event>
<event type="publishedOnlineEarlyUnpaginated" date="2013-09-12"></event>
<event type="firstOnline" date="2013-09-12"></event>
<event type="publishedOnlineFinalForm" date="2014-10-03"></event>
<event type="xmlConverted" agent="Converter:WML3G_To_WML3G version:4.6.4 mode:FullText" date="2015-10-06"></event>
</eventGroup>
<numberingGroup>
<numbering type="pageFirst">1222</numbering>
<numbering type="pageLast">1227</numbering>
</numberingGroup>
<correspondenceTo>
<lineatedText>
<line>
<b>Corresponding author:</b>
</line>
<line>
<i>Assist. Prof. Tiago Borges</i>
</line>
<line>Department of Oral Surgery and Implant Dentistry</line>
<line>Bragança Private Medical Centre</line>
<line>Rua João XXI, 59/60, R/Ch Esq., 5300‐435 Bragança, Portugal</line>
<line>Tel.: +00351 917411447</line>
<line>Fax: +00351 273328639</line>
<line>e‐mail:
<email>geral@cmeb.pt</email>
</line>
</lineatedText>
</correspondenceTo>
<selfCitationGroup>
<citation type="self" xml:id="clr12257-cit-1001">
<author>
<familyName>Borges</familyName>
<givenNames>T</givenNames>
</author>
,
<author>
<familyName>Lima</familyName>
<givenNames>T</givenNames>
</author>
,
<author>
<familyName>Carvalho</familyName>
<givenNames>Á</givenNames>
</author>
,
<author>
<familyName>Dourado</familyName>
<givenNames>C</givenNames>
</author>
,
<author>
<familyName>Carvalho</familyName>
<givenNames>V</givenNames>
</author>
.
<articleTitle>The influence of customized abutments and custom metal abutments on the presence of the interproximal papilla at implants inserted in single‐unit gaps: a 1‐year prospective clinical study</articleTitle>
.
<journalTitle>Clin. Oral Impl. Res.</journalTitle>
<vol>25</vol>
,
<pubYear year="2014">2014</pubYear>
,
<pageFirst>1222</pageFirst>
<pageLast>1227</pageLast>
doi:
<accessionId ref="info:doi/10.1111/clr.12257">10.1111/clr.12257</accessionId>
</citation>
</selfCitationGroup>
<linkGroup>
<link type="toTypesetVersion" href="file:CLR.CLR12257.pdf"></link>
</linkGroup>
</publicationMeta>
<contentMeta>
<titleGroup>
<title type="main">The influence of customized abutments and custom metal abutments on the presence of the interproximal papilla at implants inserted in single‐unit gaps: a 1‐year prospective clinical study</title>
<title type="shortAuthors">Borges et al</title>
</titleGroup>
<creators>
<creator affiliationRef="#clr12257-aff-0001" corresponding="yes" creatorRole="author" xml:id="clr12257-cr-0001">
<personName>
<givenNames>Tiago</givenNames>
<familyName>Borges</familyName>
</personName>
</creator>
<creator affiliationRef="#clr12257-aff-0002" creatorRole="author" xml:id="clr12257-cr-0002">
<personName>
<givenNames>Tiago</givenNames>
<familyName>Lima</familyName>
</personName>
</creator>
<creator affiliationRef="#clr12257-aff-0002" creatorRole="author" xml:id="clr12257-cr-0003">
<personName>
<givenNames>Ágata</givenNames>
<familyName>Carvalho</familyName>
</personName>
</creator>
<creator affiliationRef="#clr12257-aff-0003" creatorRole="author" xml:id="clr12257-cr-0004">
<personName>
<givenNames>Catarina</givenNames>
<familyName>Dourado</familyName>
</personName>
</creator>
<creator affiliationRef="#clr12257-aff-0003" creatorRole="author" xml:id="clr12257-cr-0005">
<personName>
<givenNames>Vasco</givenNames>
<familyName>Carvalho</familyName>
</personName>
</creator>
</creators>
<affiliationGroup>
<affiliation countryCode="PT" type="organization" xml:id="clr12257-aff-0001">
<orgDiv>Department of Oral Surgery and Implant Dentistry</orgDiv>
<orgName>Portuguese Catholic University</orgName>
<address>
<city>Viseu</city>
<country>Portugal</country>
</address>
</affiliation>
<affiliation countryCode="PT" type="organization" xml:id="clr12257-aff-0002">
<orgDiv>Department of Oral Surgery and Implant Dentistry</orgDiv>
<orgName>Bragança Private Medical Centre</orgName>
<address>
<city>Bragança</city>
<country>Portugal</country>
</address>
</affiliation>
<affiliation countryCode="PT" type="organization" xml:id="clr12257-aff-0003">
<orgName>Chaves Private Medical Centre</orgName>
<address>
<city>Chaves</city>
<country>Portugal</country>
</address>
</affiliation>
</affiliationGroup>
<keywordGroup type="author">
<keyword xml:id="clr12257-kwd-0001">computer‐assisted design</keyword>
<keyword xml:id="clr12257-kwd-0002">computer‐assisted manufacturing</keyword>
<keyword xml:id="clr12257-kwd-0003">implant abutments</keyword>
<keyword xml:id="clr12257-kwd-0004">interproximal papilla</keyword>
<keyword xml:id="clr12257-kwd-0005">outcomes assessment</keyword>
</keywordGroup>
<abstractGroup>
<abstract type="main" xml:id="clr12257-abs-0001">
<title type="main">Abstract</title>
<section xml:id="clr12257-sec-0001">
<title type="main">Objectives</title>
<p>To assess and compare the papilla presence mesially and distally to dental implants restored with customized abutments and custom metal abutments in the anterior maxilla.</p>
</section>
<section xml:id="clr12257-sec-0002">
<title type="main">Material and methods</title>
<p>Thirty‐eight patients receiving 38 single‐tooth implants, restored with 26 customized abutments and 12 custom metal abutments in the anterior maxillary region were enrolled in this study. The cases where did not existed contact point were excluded. Presence/absence of the interproximal papilla, inter‐tooth–implant distance (
<fc>ITD</fc>
) and distance from the base of the contact point to dental crest bone of adjacent tooth (
<fc>CPB</fc>
) were accessed. Global
<i>P</i>
‐values were determined for changes in
<fc>CPB</fc>
and papilla score over time (
<i></i>
<
<i> </i>
0.05).</p>
</section>
<section xml:id="clr12257-sec-0003">
<title type="main">Results</title>
<p>Thirty‐six patients with 36 implants were available for the 12‐month follow‐up. The abutments and reconstruction survival rate was 100% with no fracture or crown loss. A mean mesial
<fc>CPB</fc>
of 5.71 ± 1.54 mm and distal
<fc>CPB</fc>
of 4.01 ± 1.73 mm were assessed in the customized abutment group for an overall mean papilla presence of 1.69 ± 0.46. A mean mesial
<fc>CPB</fc>
of 5.41 ± 1.31 mm and distal
<fc>CPB</fc>
of 4.77 ± 1.21 mm were assessed in the control group for an overall mean papilla presence of 1.08 ± 0.65.</p>
</section>
<section xml:id="clr12257-sec-0004">
<title type="main">Conclusions</title>
<p>The restoration of single‐implants using computer‐assisted design/computer‐assisted manufacturing abutments appears to help maintaining a regular papillary filling although the variations of the implant positioning or the restoration/teeth relation.</p>
</section>
</abstract>
</abstractGroup>
</contentMeta>
</header>
</component>
</istex:document>
</istex:metadataXml>
<mods version="3.6">
<titleInfo lang="en">
<title>The influence of customized abutments and custom metal abutments on the presence of the interproximal papilla at implants inserted in single‐unit gaps: a 1‐year prospective clinical study</title>
</titleInfo>
<titleInfo type="alternative" contentType="CDATA" lang="en">
<title>The influence of customized abutments and custom metal abutments on the presence of the interproximal papilla at implants inserted in single‐unit gaps: a 1‐year prospective clinical study</title>
</titleInfo>
<name type="personal">
<namePart type="given">Tiago</namePart>
<namePart type="family">Borges</namePart>
<affiliation>Department of Oral Surgery and Implant Dentistry, Portuguese Catholic University, Viseu, Portugal</affiliation>
<affiliation>Department of Oral Surgery and Implant DentistryBragança Private Medical CentreRua João XXI, 59/60, R/Ch Esq., 5300‐435 Bragança, PortugalTel.: +00351 917411447Fax: +00351 273328639e‐mail:</affiliation>
<affiliation>E-mail: geral@cmeb.pt</affiliation>
<role>
<roleTerm type="text">author</roleTerm>
</role>
</name>
<name type="personal">
<namePart type="given">Tiago</namePart>
<namePart type="family">Lima</namePart>
<affiliation>Department of Oral Surgery and Implant Dentistry, Bragança Private Medical Centre, Bragança, Portugal</affiliation>
<role>
<roleTerm type="text">author</roleTerm>
</role>
</name>
<name type="personal">
<namePart type="given">Ágata</namePart>
<namePart type="family">Carvalho</namePart>
<affiliation>Department of Oral Surgery and Implant Dentistry, Bragança Private Medical Centre, Bragança, Portugal</affiliation>
<role>
<roleTerm type="text">author</roleTerm>
</role>
</name>
<name type="personal">
<namePart type="given">Catarina</namePart>
<namePart type="family">Dourado</namePart>
<affiliation>Chaves Private Medical Centre, Chaves, Portugal</affiliation>
<role>
<roleTerm type="text">author</roleTerm>
</role>
</name>
<name type="personal">
<namePart type="given">Vasco</namePart>
<namePart type="family">Carvalho</namePart>
<affiliation>Chaves Private Medical Centre, Chaves, Portugal</affiliation>
<role>
<roleTerm type="text">author</roleTerm>
</role>
</name>
<typeOfResource>text</typeOfResource>
<genre type="article" displayLabel="article" authority="ISTEX" authorityURI="https://content-type.data.istex.fr" valueURI="https://content-type.data.istex.fr/ark:/67375/XTP-6N5SZHKN-D">article</genre>
<originInfo>
<publisher>Blackwell Publishing Ltd</publisher>
<dateIssued encoding="w3cdtf">2014-11</dateIssued>
<dateCreated encoding="w3cdtf">2013-08-19</dateCreated>
<dateValid encoding="w3cdtf">2013-08-04</dateValid>
<edition>Borges T, Lima T, Carvalho Á, Dourado C, Carvalho V. The influence of customized abutments and custom metal abutments on the presence of the interproximal papilla at implants inserted in single‐unit gaps: a 1‐year prospective clinical study. Clin. Oral Impl. Res. 25, 2014, 1222–1227 doi: 10.1111/clr.12257</edition>
<copyrightDate encoding="w3cdtf">2014</copyrightDate>
</originInfo>
<language>
<languageTerm type="code" authority="rfc3066">en</languageTerm>
<languageTerm type="code" authority="iso639-2b">eng</languageTerm>
</language>
<abstract>To assess and compare the papilla presence mesially and distally to dental implants restored with customized abutments and custom metal abutments in the anterior maxilla.</abstract>
<abstract>Thirty‐eight patients receiving 38 single‐tooth implants, restored with 26 customized abutments and 12 custom metal abutments in the anterior maxillary region were enrolled in this study. The cases where did not existed contact point were excluded. Presence/absence of the interproximal papilla, inter‐tooth–implant distance (ITD) and distance from the base of the contact point to dental crest bone of adjacent tooth (CPB) were accessed. Global P‐values were determined for changes in CPB and papilla score over time (P < 0.05).</abstract>
<abstract>Thirty‐six patients with 36 implants were available for the 12‐month follow‐up. The abutments and reconstruction survival rate was 100% with no fracture or crown loss. A mean mesial CPB of 5.71 ± 1.54 mm and distal CPB of 4.01 ± 1.73 mm were assessed in the customized abutment group for an overall mean papilla presence of 1.69 ± 0.46. A mean mesial CPB of 5.41 ± 1.31 mm and distal CPB of 4.77 ± 1.21 mm were assessed in the control group for an overall mean papilla presence of 1.08 ± 0.65.</abstract>
<abstract>The restoration of single‐implants using computer‐assisted design/computer‐assisted manufacturing abutments appears to help maintaining a regular papillary filling although the variations of the implant positioning or the restoration/teeth relation.</abstract>
<subject>
<genre>keywords</genre>
<topic>computer‐assisted design</topic>
<topic>computer‐assisted manufacturing</topic>
<topic>implant abutments</topic>
<topic>interproximal papilla</topic>
<topic>outcomes assessment</topic>
</subject>
<relatedItem type="host">
<titleInfo>
<title>Clinical Oral Implants Research</title>
</titleInfo>
<titleInfo type="abbreviated">
<title>Clin. Oral Impl. Res.</title>
</titleInfo>
<genre type="journal" authority="ISTEX" authorityURI="https://publication-type.data.istex.fr" valueURI="https://publication-type.data.istex.fr/ark:/67375/JMC-0GLKJH51-B">journal</genre>
<subject>
<genre>article-category</genre>
<topic>Original Article</topic>
</subject>
<identifier type="ISSN">0905-7161</identifier>
<identifier type="eISSN">1600-0501</identifier>
<identifier type="DOI">10.1111/(ISSN)1600-0501</identifier>
<identifier type="PublisherID">CLR</identifier>
<part>
<date>2014</date>
<detail type="volume">
<caption>vol.</caption>
<number>25</number>
</detail>
<detail type="issue">
<caption>no.</caption>
<number>11</number>
</detail>
<extent unit="pages">
<start>1222</start>
<end>1227</end>
<total>6</total>
</extent>
</part>
</relatedItem>
<identifier type="istex">7F9C67B6183AA42AE75D13C08AFD2976B6D75B13</identifier>
<identifier type="ark">ark:/67375/WNG-TW2PP1CS-1</identifier>
<identifier type="DOI">10.1111/clr.12257</identifier>
<identifier type="ArticleID">CLR12257</identifier>
<accessCondition type="use and reproduction" contentType="copyright">Copyright © 2014 John Wiley & Sons Ltd© 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd</accessCondition>
<recordInfo>
<recordContentSource authority="ISTEX" authorityURI="https://loaded-corpus.data.istex.fr" valueURI="https://loaded-corpus.data.istex.fr/ark:/67375/XBH-L0C46X92-X">wiley</recordContentSource>
</recordInfo>
</mods>
<json:item>
<extension>json</extension>
<original>false</original>
<mimetype>application/json</mimetype>
<uri>https://api.istex.fr/document/7F9C67B6183AA42AE75D13C08AFD2976B6D75B13/metadata/json</uri>
</json:item>
</metadata>
<serie></serie>
</istex>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Istex/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 003F27 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Istex/Corpus/biblio.hfd -nk 003F27 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    Istex
   |étape=   Corpus
   |type=    RBID
   |clé=     ISTEX:7F9C67B6183AA42AE75D13C08AFD2976B6D75B13
   |texte=   The influence of customized abutments and custom metal abutments on the presence of the interproximal papilla at implants inserted in single‐unit gaps: a 1‐year prospective clinical study
}}

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022