Serveur d'exploration sur le patient édenté

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Effect of repeated cycles of chemical disinfection on the roughness and hardness of hard reline acrylic resins

Identifieur interne : 000171 ( Istex/Corpus ); précédent : 000170; suivant : 000172

Effect of repeated cycles of chemical disinfection on the roughness and hardness of hard reline acrylic resins

Auteurs : Luciana De Rezende Pinto ; Emílio José T. Rodríguez Acosta ; Flora Freitas Fernandes Távora ; Paulo Maurício Batista Da Silva ; Vinícius Carvalho Porto

Source :

RBID : ISTEX:0372F43A7A10575A0F398B1A6C872F2BD9D90F49

English descriptors

Abstract

doi:10.1111/j.1741‐2358.2009.00282.x 
 Effect of repeated cycles of chemical disinfection on the roughness and hardness of hard reline acrylic resins

Url:
DOI: 10.1111/j.1741-2358.2009.00282.x

Links to Exploration step

ISTEX:0372F43A7A10575A0F398B1A6C872F2BD9D90F49

Le document en format XML

<record>
<TEI wicri:istexFullTextTei="biblStruct">
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Effect of repeated cycles of chemical disinfection on the roughness and hardness of hard reline acrylic resins</title>
<author>
<name sortKey="De Rezende Pinto, Luciana" sort="De Rezende Pinto, Luciana" uniqKey="De Rezende Pinto L" first="Luciana" last="De Rezende Pinto">Luciana De Rezende Pinto</name>
<affiliation>
<mods:affiliation>Department of Prosthodontics, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Rodriguez Acosta, Emilio Jose T" sort="Rodriguez Acosta, Emilio Jose T" uniqKey="Rodriguez Acosta E" first="Emílio José T." last="Rodríguez Acosta">Emílio José T. Rodríguez Acosta</name>
<affiliation>
<mods:affiliation>Department of Prosthodontics, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Tavora, Flora Freitas Fernandes" sort="Tavora, Flora Freitas Fernandes" uniqKey="Tavora F" first="Flora Freitas Fernandes" last="Távora">Flora Freitas Fernandes Távora</name>
<affiliation>
<mods:affiliation>Department of Prosthodontics, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Da Silva, Paulo Mauricio Batista" sort="Da Silva, Paulo Mauricio Batista" uniqKey="Da Silva P" first="Paulo Maurício Batista" last="Da Silva">Paulo Maurício Batista Da Silva</name>
<affiliation>
<mods:affiliation>Department of Prosthodontics, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Porto, Vinicius Carvalho" sort="Porto, Vinicius Carvalho" uniqKey="Porto V" first="Vinícius Carvalho" last="Porto">Vinícius Carvalho Porto</name>
<affiliation>
<mods:affiliation>Department of Prosthodontics, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil</mods:affiliation>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:0372F43A7A10575A0F398B1A6C872F2BD9D90F49</idno>
<date when="2010" year="2010">2010</date>
<idno type="doi">10.1111/j.1741-2358.2009.00282.x</idno>
<idno type="url">https://api.istex.fr/document/0372F43A7A10575A0F398B1A6C872F2BD9D90F49/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">000171</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Corpus" wicri:corpus="ISTEX">000171</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title level="a" type="main">Effect of repeated cycles of chemical disinfection on the roughness and hardness of hard reline acrylic resins</title>
<author>
<name sortKey="De Rezende Pinto, Luciana" sort="De Rezende Pinto, Luciana" uniqKey="De Rezende Pinto L" first="Luciana" last="De Rezende Pinto">Luciana De Rezende Pinto</name>
<affiliation>
<mods:affiliation>Department of Prosthodontics, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Rodriguez Acosta, Emilio Jose T" sort="Rodriguez Acosta, Emilio Jose T" uniqKey="Rodriguez Acosta E" first="Emílio José T." last="Rodríguez Acosta">Emílio José T. Rodríguez Acosta</name>
<affiliation>
<mods:affiliation>Department of Prosthodontics, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Tavora, Flora Freitas Fernandes" sort="Tavora, Flora Freitas Fernandes" uniqKey="Tavora F" first="Flora Freitas Fernandes" last="Távora">Flora Freitas Fernandes Távora</name>
<affiliation>
<mods:affiliation>Department of Prosthodontics, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Da Silva, Paulo Mauricio Batista" sort="Da Silva, Paulo Mauricio Batista" uniqKey="Da Silva P" first="Paulo Maurício Batista" last="Da Silva">Paulo Maurício Batista Da Silva</name>
<affiliation>
<mods:affiliation>Department of Prosthodontics, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Porto, Vinicius Carvalho" sort="Porto, Vinicius Carvalho" uniqKey="Porto V" first="Vinícius Carvalho" last="Porto">Vinícius Carvalho Porto</name>
<affiliation>
<mods:affiliation>Department of Prosthodontics, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil</mods:affiliation>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series>
<title level="j" type="main">Gerodontology</title>
<title level="j" type="alt">GERODONTOLOGY</title>
<idno type="ISSN">0734-0664</idno>
<idno type="eISSN">1741-2358</idno>
<imprint>
<biblScope unit="vol">27</biblScope>
<biblScope unit="issue">2</biblScope>
<biblScope unit="page" from="147">147</biblScope>
<biblScope unit="page" to="153">153</biblScope>
<biblScope unit="page-count">7</biblScope>
<publisher>Blackwell Publishing Ltd</publisher>
<pubPlace>Oxford, UK</pubPlace>
<date type="published" when="2010-06">2010-06</date>
</imprint>
<idno type="ISSN">0734-0664</idno>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt>
<idno type="ISSN">0734-0664</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Acrylic resin</term>
<term>Albicans</term>
<term>Authors journal compilation</term>
<term>Blackwell munksgaard</term>
<term>Candida</term>
<term>Candida albicans</term>
<term>Chemical disinfectant solutions</term>
<term>Chemical disinfectants</term>
<term>Chemical disinfection</term>
<term>Chemical solutions</term>
<term>Community dent</term>
<term>Deionised</term>
<term>Deionised water</term>
<term>Dent</term>
<term>Denture</term>
<term>Denture cleansers</term>
<term>Denture plaque</term>
<term>Denture stomatitis</term>
<term>Denture wearers</term>
<term>Disinfectant</term>
<term>Disinfectant solution</term>
<term>Disinfectant solutions</term>
<term>Disinfection</term>
<term>Disinfection protocol</term>
<term>Gerodontology</term>
<term>Gerodontology association</term>
<term>Hard reline acrylic resins</term>
<term>Hardness</term>
<term>Hardness values</term>
<term>Immersion</term>
<term>Immersion cycles</term>
<term>Kooliner</term>
<term>Kooliner tokuyama rebase</term>
<term>Munksgaard</term>
<term>Oral rehabil</term>
<term>Prosthet</term>
<term>Prosthet dent</term>
<term>Rebase</term>
<term>Rehabil</term>
<term>Reline</term>
<term>Resin</term>
<term>Rezende pinto</term>
<term>Roughness</term>
<term>Sodium hypochlorite</term>
<term>Statistical analysis</term>
<term>Surface roughness</term>
<term>Threshold surface roughness</term>
<term>Tokuyama</term>
<term>Tokuyama rebase</term>
<term>Water immersion</term>
</keywords>
<keywords scheme="Teeft" xml:lang="en">
<term>Acrylic resin</term>
<term>Albicans</term>
<term>Authors journal compilation</term>
<term>Blackwell munksgaard</term>
<term>Candida</term>
<term>Candida albicans</term>
<term>Chemical disinfectant solutions</term>
<term>Chemical disinfectants</term>
<term>Chemical disinfection</term>
<term>Chemical solutions</term>
<term>Community dent</term>
<term>Deionised</term>
<term>Deionised water</term>
<term>Dent</term>
<term>Denture</term>
<term>Denture cleansers</term>
<term>Denture plaque</term>
<term>Denture stomatitis</term>
<term>Denture wearers</term>
<term>Disinfectant</term>
<term>Disinfectant solution</term>
<term>Disinfectant solutions</term>
<term>Disinfection</term>
<term>Disinfection protocol</term>
<term>Gerodontology</term>
<term>Gerodontology association</term>
<term>Hard reline acrylic resins</term>
<term>Hardness</term>
<term>Hardness values</term>
<term>Immersion</term>
<term>Immersion cycles</term>
<term>Kooliner</term>
<term>Kooliner tokuyama rebase</term>
<term>Munksgaard</term>
<term>Oral rehabil</term>
<term>Prosthet</term>
<term>Prosthet dent</term>
<term>Rebase</term>
<term>Rehabil</term>
<term>Reline</term>
<term>Resin</term>
<term>Rezende pinto</term>
<term>Roughness</term>
<term>Sodium hypochlorite</term>
<term>Statistical analysis</term>
<term>Surface roughness</term>
<term>Threshold surface roughness</term>
<term>Tokuyama</term>
<term>Tokuyama rebase</term>
<term>Water immersion</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract">doi:10.1111/j.1741‐2358.2009.00282.x 
 Effect of repeated cycles of chemical disinfection on the roughness and hardness of hard reline acrylic resins</div>
</front>
</TEI>
<istex>
<corpusName>wiley</corpusName>
<keywords>
<teeft>
<json:string>denture</json:string>
<json:string>disinfection</json:string>
<json:string>reline</json:string>
<json:string>disinfectant</json:string>
<json:string>tokuyama</json:string>
<json:string>gerodontology</json:string>
<json:string>surface roughness</json:string>
<json:string>kooliner</json:string>
<json:string>deionised</json:string>
<json:string>prosthet dent</json:string>
<json:string>prosthet</json:string>
<json:string>deionised water</json:string>
<json:string>hardness</json:string>
<json:string>chemical solutions</json:string>
<json:string>oral rehabil</json:string>
<json:string>rehabil</json:string>
<json:string>rebase</json:string>
<json:string>candida</json:string>
<json:string>blackwell munksgaard</json:string>
<json:string>munksgaard</json:string>
<json:string>authors journal compilation</json:string>
<json:string>gerodontology association</json:string>
<json:string>roughness</json:string>
<json:string>immersion cycles</json:string>
<json:string>candida albicans</json:string>
<json:string>disinfectant solutions</json:string>
<json:string>chemical disinfection</json:string>
<json:string>immersion</json:string>
<json:string>dent</json:string>
<json:string>acrylic resin</json:string>
<json:string>tokuyama rebase</json:string>
<json:string>sodium hypochlorite</json:string>
<json:string>water immersion</json:string>
<json:string>disinfection protocol</json:string>
<json:string>rezende pinto</json:string>
<json:string>denture plaque</json:string>
<json:string>albicans</json:string>
<json:string>disinfectant solution</json:string>
<json:string>hard reline acrylic resins</json:string>
<json:string>chemical disinfectants</json:string>
<json:string>threshold surface roughness</json:string>
<json:string>kooliner tokuyama rebase</json:string>
<json:string>chemical disinfectant solutions</json:string>
<json:string>denture stomatitis</json:string>
<json:string>community dent</json:string>
<json:string>statistical analysis</json:string>
<json:string>denture wearers</json:string>
<json:string>hardness values</json:string>
<json:string>denture cleansers</json:string>
<json:string>resin</json:string>
</teeft>
</keywords>
<author>
<json:item>
<name>Luciana De Rezende Pinto</name>
<affiliations>
<json:string>Department of Prosthodontics, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil</json:string>
</affiliations>
</json:item>
<json:item>
<name>Emílio José T. Rodríguez Acosta</name>
<affiliations>
<json:string>Department of Prosthodontics, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil</json:string>
</affiliations>
</json:item>
<json:item>
<name>Flora Freitas Fernandes Távora</name>
<affiliations>
<json:string>Department of Prosthodontics, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil</json:string>
</affiliations>
</json:item>
<json:item>
<name>Paulo Maurício Batista Da Silva</name>
<affiliations>
<json:string>Department of Prosthodontics, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil</json:string>
</affiliations>
</json:item>
<json:item>
<name>Vinícius Carvalho Porto</name>
<affiliations>
<json:string>Department of Prosthodontics, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil</json:string>
</affiliations>
</json:item>
</author>
<subject>
<json:item>
<lang>
<json:string>eng</json:string>
</lang>
<value>hard reline acrylic resin</value>
</json:item>
<json:item>
<lang>
<json:string>eng</json:string>
</lang>
<value>denture disinfection</value>
</json:item>
<json:item>
<lang>
<json:string>eng</json:string>
</lang>
<value>surface roughness</value>
</json:item>
<json:item>
<lang>
<json:string>eng</json:string>
</lang>
<value>hardness</value>
</json:item>
</subject>
<articleId>
<json:string>GER282</json:string>
</articleId>
<arkIstex>ark:/67375/WNG-SB8N56P2-J</arkIstex>
<language>
<json:string>eng</json:string>
</language>
<originalGenre>
<json:string>article</json:string>
</originalGenre>
<abstract>doi:10.1111/j.1741‐2358.2009.00282.x Effect of repeated cycles of chemical disinfection on the roughness and hardness of hard reline acrylic resins</abstract>
<qualityIndicators>
<refBibsNative>true</refBibsNative>
<abstractWordCount>19</abstractWordCount>
<abstractCharCount>149</abstractCharCount>
<keywordCount>4</keywordCount>
<score>6.21</score>
<pdfWordCount>3982</pdfWordCount>
<pdfCharCount>26156</pdfCharCount>
<pdfVersion>1.3</pdfVersion>
<pdfPageCount>7</pdfPageCount>
<pdfPageSize>595.276 x 790.866 pts</pdfPageSize>
</qualityIndicators>
<title>Effect of repeated cycles of chemical disinfection on the roughness and hardness of hard reline acrylic resins</title>
<pmid>
<json:string>19508322</json:string>
</pmid>
<genre>
<json:string>article</json:string>
</genre>
<host>
<title>Gerodontology</title>
<language>
<json:string>unknown</json:string>
</language>
<doi>
<json:string>10.1111/(ISSN)1741-2358</json:string>
</doi>
<issn>
<json:string>0734-0664</json:string>
</issn>
<eissn>
<json:string>1741-2358</json:string>
</eissn>
<publisherId>
<json:string>GER</json:string>
</publisherId>
<volume>27</volume>
<issue>2</issue>
<pages>
<first>147</first>
<last>153</last>
<total>7</total>
</pages>
<genre>
<json:string>journal</json:string>
</genre>
</host>
<namedEntities>
<unitex>
<date>
<json:string>2010</json:string>
</date>
<geogName></geogName>
<orgName>
<json:string>Blackwell Munksgaard Ltd</json:string>
<json:string>Foundation of Research</json:string>
</orgName>
<orgName_funder></orgName_funder>
<orgName_provider></orgName_provider>
<persName>
<json:string>Vin</json:string>
<json:string>Paulo Maur</json:string>
<json:string>Kooliner</json:string>
<json:string>Dr Claudinei</json:string>
<json:string>Flora Freitas</json:string>
<json:string>Margery Galbraith</json:string>
<json:string>Batista da Silva</json:string>
</persName>
<placeName>
<json:string>Germany</json:string>
<json:string>Japan</json:string>
<json:string>Tokyo</json:string>
</placeName>
<ref_url></ref_url>
<ref_bibl>
<json:string>International Organization for Standardization Specification 1567, 1988</json:string>
<json:string>Ma et al.</json:string>
<json:string>Shen et al.</json:string>
<json:string>Pinto et al.</json:string>
<json:string>American Dental Association, 1975</json:string>
</ref_bibl>
<bibl></bibl>
</unitex>
</namedEntities>
<ark>
<json:string>ark:/67375/WNG-SB8N56P2-J</json:string>
</ark>
<categories>
<wos>
<json:string>1 - science</json:string>
<json:string>2 - geriatrics & gerontology</json:string>
<json:string>2 - dentistry, oral surgery & medicine</json:string>
</wos>
<scienceMetrix>
<json:string>1 - health sciences</json:string>
<json:string>2 - clinical medicine</json:string>
<json:string>3 - dentistry</json:string>
</scienceMetrix>
<scopus>
<json:string>1 - Health Sciences</json:string>
<json:string>2 - Medicine</json:string>
<json:string>3 - Geriatrics and Gerontology</json:string>
<json:string>1 - Health Sciences</json:string>
<json:string>2 - Dentistry</json:string>
<json:string>3 - General Dentistry</json:string>
</scopus>
</categories>
<publicationDate>2010</publicationDate>
<copyrightDate>2010</copyrightDate>
<doi>
<json:string>10.1111/j.1741-2358.2009.00282.x</json:string>
</doi>
<id>0372F43A7A10575A0F398B1A6C872F2BD9D90F49</id>
<score>1</score>
<fulltext>
<json:item>
<extension>pdf</extension>
<original>true</original>
<mimetype>application/pdf</mimetype>
<uri>https://api.istex.fr/document/0372F43A7A10575A0F398B1A6C872F2BD9D90F49/fulltext/pdf</uri>
</json:item>
<json:item>
<extension>zip</extension>
<original>false</original>
<mimetype>application/zip</mimetype>
<uri>https://api.istex.fr/document/0372F43A7A10575A0F398B1A6C872F2BD9D90F49/fulltext/zip</uri>
</json:item>
<istex:fulltextTEI uri="https://api.istex.fr/document/0372F43A7A10575A0F398B1A6C872F2BD9D90F49/fulltext/tei">
<teiHeader>
<fileDesc>
<titleStmt>
<title level="a" type="main">Effect of repeated cycles of chemical disinfection on the roughness and hardness of hard reline acrylic resins</title>
</titleStmt>
<publicationStmt>
<authority>ISTEX</authority>
<publisher>Blackwell Publishing Ltd</publisher>
<pubPlace>Oxford, UK</pubPlace>
<availability>
<licence>© 2009 The Authors. Journal compilation © 2009 The Gerodontology Association and Blackwell Munksgaard Ltd</licence>
</availability>
<date type="published" when="2010-06"></date>
</publicationStmt>
<notesStmt>
<note type="content-type" subtype="article" source="article" scheme="https://content-type.data.istex.fr/ark:/67375/XTP-6N5SZHKN-D">article</note>
<note type="publication-type" subtype="journal" scheme="https://publication-type.data.istex.fr/ark:/67375/JMC-0GLKJH51-B">journal</note>
</notesStmt>
<sourceDesc>
<biblStruct type="article">
<analytic>
<title level="a" type="main">Effect of repeated cycles of chemical disinfection on the roughness and hardness of hard reline acrylic resins</title>
<title level="a" type="short">Effect of chemical disinfection on reliners</title>
<author xml:id="author-0000">
<persName>
<forename type="first">Luciana</forename>
<surname>De Rezende Pinto</surname>
</persName>
<affiliation>Department of Prosthodontics, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil
<address>
<country key="BR"></country>
</address>
</affiliation>
</author>
<author xml:id="author-0001">
<persName>
<forename type="first">Emílio José T.</forename>
<surname>Rodríguez Acosta</surname>
</persName>
<affiliation>Department of Prosthodontics, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil
<address>
<country key="BR"></country>
</address>
</affiliation>
</author>
<author xml:id="author-0002">
<persName>
<forename type="first">Flora Freitas Fernandes</forename>
<surname>Távora</surname>
</persName>
<affiliation>Department of Prosthodontics, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil
<address>
<country key="BR"></country>
</address>
</affiliation>
</author>
<author xml:id="author-0003">
<persName>
<forename type="first">Paulo Maurício Batista</forename>
<surname>Da Silva</surname>
</persName>
<affiliation>Department of Prosthodontics, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil
<address>
<country key="BR"></country>
</address>
</affiliation>
</author>
<author xml:id="author-0004">
<persName>
<forename type="first">Vinícius Carvalho</forename>
<surname>Porto</surname>
</persName>
<affiliation>Department of Prosthodontics, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil
<address>
<country key="BR"></country>
</address>
</affiliation>
</author>
<idno type="istex">0372F43A7A10575A0F398B1A6C872F2BD9D90F49</idno>
<idno type="ark">ark:/67375/WNG-SB8N56P2-J</idno>
<idno type="DOI">10.1111/j.1741-2358.2009.00282.x</idno>
<idno type="unit">GER282</idno>
<idno type="toTypesetVersion">file:GER.GER282.pdf</idno>
</analytic>
<monogr>
<title level="j" type="main">Gerodontology</title>
<title level="j" type="alt">GERODONTOLOGY</title>
<idno type="pISSN">0734-0664</idno>
<idno type="eISSN">1741-2358</idno>
<idno type="book-DOI">10.1111/(ISSN)1741-2358</idno>
<idno type="book-part-DOI">10.1111/ger.2010.27.issue-2</idno>
<idno type="product">GER</idno>
<idno type="publisherDivision">ST</idno>
<imprint>
<biblScope unit="vol">27</biblScope>
<biblScope unit="issue">2</biblScope>
<biblScope unit="page" from="147">147</biblScope>
<biblScope unit="page" to="153">153</biblScope>
<biblScope unit="page-count">7</biblScope>
<publisher>Blackwell Publishing Ltd</publisher>
<pubPlace>Oxford, UK</pubPlace>
<date type="published" when="2010-06"></date>
</imprint>
</monogr>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<abstract xml:lang="en" style="main">
<p>
<hi rend="italic">doi:10.1111/j.1741‐2358.2009.00282.x</hi>
<hi rend="bold">Effect of repeated cycles of chemical disinfection on the roughness and hardness of hard reline acrylic resins</hi>
</p>
<p>
<hi rend="bold">Objective: </hi>
The aim of this study was to assess the effect of repeated cycles of five chemical disinfectant solutions on the roughness and hardness of three hard chairside reliners.</p>
<p>
<hi rend="bold">Methods: </hi>
A total of 180 circular specimens (30 mm × 6 mm) were fabricated using three hard chairside reliners (Jet;
<hi rend="italic">n</hi>
 = 60, Kooliner;
<hi rend="italic">n</hi>
 = 60, Tokuyama Rebase II Fast;
<hi rend="italic">n</hi>
 = 60), which were immersed in deionised water (control), and five disinfectant solutions (1%, 2%, 5.25% sodium hypochlorite; 2% glutaraldehyde; 4% chlorhexidine gluconate). They were tested for Knoop hardness (KHN) and surface roughness (μm), before and after 30 simulated disinfecting cycles. Data was analysed by the factorial scheme (6 × 2), two‐way analysis of variance (
<hi rend="smallCaps">anova</hi>
), followed by Tukey’s test.</p>
<p>
<hi rend="bold">Results: </hi>
For Jet (from 18.74 to 13.86 KHN), Kooliner (from 14.09 to 8.72 KHN), Tokuyama (from 12.57 to 8.28 KHN) a significant decrease in hardness was observed irrespective of the solution used on all materials. For Jet (from 0.09 to 0.11 μm) there was a statistically significant increase in roughness. Kooliner (from 0.36 to 0.26 μm) presented a statistically significant decrease in roughness and Tokuyama (from 0.15 to 0.11 μm) presented no statistically significant difference after 30 days.</p>
<p>
<hi rend="bold">Conclusions: </hi>
This study showed that all disinfectant solutions promoted a statistically significant decrease in hardness, whereas with roughness, the materials tested showed a statistically significant increase, except for Tokuyama. Although statistically significant values were registered, these results could not be considered clinically significant.</p>
</abstract>
<textClass>
<keywords xml:lang="en">
<term xml:id="k1">hard reline acrylic resin</term>
<term xml:id="k2">denture disinfection</term>
<term xml:id="k3">surface roughness</term>
<term xml:id="k4">hardness</term>
</keywords>
<keywords rend="tocHeading1">
<term>Original Articles</term>
</keywords>
</textClass>
<langUsage>
<language ident="en"></language>
</langUsage>
</profileDesc>
</teiHeader>
</istex:fulltextTEI>
<json:item>
<extension>txt</extension>
<original>false</original>
<mimetype>text/plain</mimetype>
<uri>https://api.istex.fr/document/0372F43A7A10575A0F398B1A6C872F2BD9D90F49/fulltext/txt</uri>
</json:item>
</fulltext>
<metadata>
<istex:metadataXml wicri:clean="Wiley, elements deleted: body">
<istex:xmlDeclaration>version="1.0" encoding="UTF-8" standalone="yes"</istex:xmlDeclaration>
<istex:document>
<component version="2.0" type="serialArticle" xml:lang="en">
<header>
<publicationMeta level="product">
<publisherInfo>
<publisherName>Blackwell Publishing Ltd</publisherName>
<publisherLoc>Oxford, UK</publisherLoc>
</publisherInfo>
<doi origin="wiley" registered="yes">10.1111/(ISSN)1741-2358</doi>
<issn type="print">0734-0664</issn>
<issn type="electronic">1741-2358</issn>
<idGroup>
<id type="product" value="GER"></id>
<id type="publisherDivision" value="ST"></id>
</idGroup>
<titleGroup>
<title type="main" sort="GERODONTOLOGY">Gerodontology</title>
</titleGroup>
</publicationMeta>
<publicationMeta level="part" position="06002">
<doi origin="wiley">10.1111/ger.2010.27.issue-2</doi>
<numberingGroup>
<numbering type="journalVolume" number="27">27</numbering>
<numbering type="journalIssue" number="2">2</numbering>
</numberingGroup>
<coverDate startDate="2010-06">June 2010</coverDate>
</publicationMeta>
<publicationMeta level="unit" type="article" position="10" status="forIssue">
<doi origin="wiley">10.1111/j.1741-2358.2009.00282.x</doi>
<idGroup>
<id type="unit" value="GER282"></id>
</idGroup>
<countGroup>
<count type="pageTotal" number="7"></count>
</countGroup>
<titleGroup>
<title type="tocHeading1">
<i>Original Articles</i>
</title>
</titleGroup>
<copyright>© 2009 The Authors. Journal compilation © 2009 The Gerodontology Association and Blackwell Munksgaard Ltd</copyright>
<eventGroup>
<event type="firstOnline" date="2009-06-08"></event>
<event type="publishedOnlineFinalForm" date="2010-05-26"></event>
<event type="xmlConverted" agent="Converter:BPG_TO_WML3G version:2.3.6 mode:FullText source:FullText result:FullText" date="2010-05-27"></event>
<event type="xmlConverted" agent="Converter:WILEY_ML3G_TO_WILEY_ML3GV2 version:3.8.8" date="2014-01-26"></event>
<event type="xmlConverted" agent="Converter:WML3G_To_WML3G version:4.1.7 mode:FullText,remove_FC" date="2014-10-23"></event>
</eventGroup>
<numberingGroup>
<numbering type="pageFirst" number="147">147</numbering>
<numbering type="pageLast" number="153">153</numbering>
</numberingGroup>
<correspondenceTo>Vinícius Carvalho Porto, Rua Alameda Dr. Otávio Pinheiro Brizola, no. 9‐75, Bauru, São Paulo, Brazil, CEP 17012‐901.
Tel.: +55 014 9785 3998
Fax: +55 14 3223 4679
E‐mail:
<email>vcporto@fob.usp.br</email>
</correspondenceTo>
<linkGroup>
<link type="toTypesetVersion" href="file:GER.GER282.pdf"></link>
</linkGroup>
</publicationMeta>
<contentMeta>
<unparsedEditorialHistory>Accepted 12 January 2009</unparsedEditorialHistory>
<countGroup>
<count type="figureTotal" number="0"></count>
<count type="tableTotal" number="3"></count>
</countGroup>
<titleGroup>
<title type="main">Effect of repeated cycles of chemical disinfection on the roughness and hardness of hard reline acrylic resins</title>
<title type="shortAuthors">
<i>L. de Rezende Pinto et al.</i>
</title>
<title type="short">
<i>Effect of chemical disinfection on reliners</i>
</title>
</titleGroup>
<creators>
<creator creatorRole="author" xml:id="cr1" affiliationRef="#aff-1-1">
<personName>
<givenNames>Luciana</givenNames>
<familyName>De Rezende Pinto</familyName>
</personName>
</creator>
<creator creatorRole="author" xml:id="cr2" affiliationRef="#aff-1-1">
<personName>
<givenNames>Emílio José T.</givenNames>
<familyName>Rodríguez Acosta</familyName>
</personName>
</creator>
<creator creatorRole="author" xml:id="cr3" affiliationRef="#aff-1-1">
<personName>
<givenNames>Flora Freitas Fernandes</givenNames>
<familyName>Távora</familyName>
</personName>
</creator>
<creator creatorRole="author" xml:id="cr4" affiliationRef="#aff-1-1">
<personName>
<givenNames>Paulo Maurício Batista</givenNames>
<familyName>Da Silva</familyName>
</personName>
</creator>
<creator creatorRole="author" xml:id="cr5" affiliationRef="#aff-1-1">
<personName>
<givenNames>Vinícius Carvalho</givenNames>
<familyName>Porto</familyName>
</personName>
</creator>
</creators>
<affiliationGroup>
<affiliation xml:id="aff-1-1" countryCode="BR">
<unparsedAffiliation>Department of Prosthodontics, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil</unparsedAffiliation>
</affiliation>
</affiliationGroup>
<keywordGroup xml:lang="en">
<keyword xml:id="k1">hard reline acrylic resin</keyword>
<keyword xml:id="k2">denture disinfection</keyword>
<keyword xml:id="k3">surface roughness</keyword>
<keyword xml:id="k4">hardness</keyword>
</keywordGroup>
<abstractGroup>
<abstract type="main" xml:lang="en">
<p>
<i>doi:10.1111/j.1741‐2358.2009.00282.x</i>
<b>Effect of repeated cycles of chemical disinfection on the roughness and hardness of hard reline acrylic resins</b>
</p>
<p>
<b>Objective: </b>
The aim of this study was to assess the effect of repeated cycles of five chemical disinfectant solutions on the roughness and hardness of three hard chairside reliners.</p>
<p>
<b>Methods: </b>
A total of 180 circular specimens (30 mm × 6 mm) were fabricated using three hard chairside reliners (Jet;
<i>n</i>
 = 60, Kooliner;
<i>n</i>
 = 60, Tokuyama Rebase II Fast;
<i>n</i>
 = 60), which were immersed in deionised water (control), and five disinfectant solutions (1%, 2%, 5.25% sodium hypochlorite; 2% glutaraldehyde; 4% chlorhexidine gluconate). They were tested for Knoop hardness (KHN) and surface roughness (μm), before and after 30 simulated disinfecting cycles. Data was analysed by the factorial scheme (6 × 2), two‐way analysis of variance (
<sc>anova</sc>
), followed by Tukey’s test.</p>
<p>
<b>Results: </b>
For Jet (from 18.74 to 13.86 KHN), Kooliner (from 14.09 to 8.72 KHN), Tokuyama (from 12.57 to 8.28 KHN) a significant decrease in hardness was observed irrespective of the solution used on all materials. For Jet (from 0.09 to 0.11 μm) there was a statistically significant increase in roughness. Kooliner (from 0.36 to 0.26 μm) presented a statistically significant decrease in roughness and Tokuyama (from 0.15 to 0.11 μm) presented no statistically significant difference after 30 days.</p>
<p>
<b>Conclusions: </b>
This study showed that all disinfectant solutions promoted a statistically significant decrease in hardness, whereas with roughness, the materials tested showed a statistically significant increase, except for Tokuyama. Although statistically significant values were registered, these results could not be considered clinically significant.</p>
</abstract>
</abstractGroup>
</contentMeta>
</header>
</component>
</istex:document>
</istex:metadataXml>
<mods version="3.6">
<titleInfo lang="en">
<title>Effect of repeated cycles of chemical disinfection on the roughness and hardness of hard reline acrylic resins</title>
</titleInfo>
<titleInfo type="abbreviated" lang="en">
<title>Effect of chemical disinfection on reliners</title>
</titleInfo>
<titleInfo type="alternative" contentType="CDATA" lang="en">
<title>Effect of repeated cycles of chemical disinfection on the roughness and hardness of hard reline acrylic resins</title>
</titleInfo>
<name type="personal">
<namePart type="given">Luciana</namePart>
<namePart type="family">De Rezende Pinto</namePart>
<affiliation>Department of Prosthodontics, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil</affiliation>
<role>
<roleTerm type="text">author</roleTerm>
</role>
</name>
<name type="personal">
<namePart type="given">Emílio José T.</namePart>
<namePart type="family">Rodríguez Acosta</namePart>
<affiliation>Department of Prosthodontics, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil</affiliation>
<role>
<roleTerm type="text">author</roleTerm>
</role>
</name>
<name type="personal">
<namePart type="given">Flora Freitas Fernandes</namePart>
<namePart type="family">Távora</namePart>
<affiliation>Department of Prosthodontics, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil</affiliation>
<role>
<roleTerm type="text">author</roleTerm>
</role>
</name>
<name type="personal">
<namePart type="given">Paulo Maurício Batista</namePart>
<namePart type="family">Da Silva</namePart>
<affiliation>Department of Prosthodontics, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil</affiliation>
<role>
<roleTerm type="text">author</roleTerm>
</role>
</name>
<name type="personal">
<namePart type="given">Vinícius Carvalho</namePart>
<namePart type="family">Porto</namePart>
<affiliation>Department of Prosthodontics, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil</affiliation>
<role>
<roleTerm type="text">author</roleTerm>
</role>
</name>
<typeOfResource>text</typeOfResource>
<genre type="article" displayLabel="article" authority="ISTEX" authorityURI="https://content-type.data.istex.fr" valueURI="https://content-type.data.istex.fr/ark:/67375/XTP-6N5SZHKN-D">article</genre>
<originInfo>
<publisher>Blackwell Publishing Ltd</publisher>
<place>
<placeTerm type="text">Oxford, UK</placeTerm>
</place>
<dateIssued encoding="w3cdtf">2010-06</dateIssued>
<edition>Accepted 12 January 2009</edition>
<copyrightDate encoding="w3cdtf">2010</copyrightDate>
</originInfo>
<language>
<languageTerm type="code" authority="rfc3066">en</languageTerm>
<languageTerm type="code" authority="iso639-2b">eng</languageTerm>
</language>
<physicalDescription>
<extent unit="figures">0</extent>
<extent unit="tables">3</extent>
</physicalDescription>
<abstract>doi:10.1111/j.1741‐2358.2009.00282.x 
 Effect of repeated cycles of chemical disinfection on the roughness and hardness of hard reline acrylic resins</abstract>
<abstract>Objective:  The aim of this study was to assess the effect of repeated cycles of five chemical disinfectant solutions on the roughness and hardness of three hard chairside reliners.</abstract>
<abstract>Methods:  A total of 180 circular specimens (30 mm × 6 mm) were fabricated using three hard chairside reliners (Jet; n = 60, Kooliner; n = 60, Tokuyama Rebase II Fast; n = 60), which were immersed in deionised water (control), and five disinfectant solutions (1%, 2%, 5.25% sodium hypochlorite; 2% glutaraldehyde; 4% chlorhexidine gluconate). They were tested for Knoop hardness (KHN) and surface roughness (μm), before and after 30 simulated disinfecting cycles. Data was analysed by the factorial scheme (6 × 2), two‐way analysis of variance (anova), followed by Tukey’s test.</abstract>
<abstract>Results:  For Jet (from 18.74 to 13.86 KHN), Kooliner (from 14.09 to 8.72 KHN), Tokuyama (from 12.57 to 8.28 KHN) a significant decrease in hardness was observed irrespective of the solution used on all materials. For Jet (from 0.09 to 0.11 μm) there was a statistically significant increase in roughness. Kooliner (from 0.36 to 0.26 μm) presented a statistically significant decrease in roughness and Tokuyama (from 0.15 to 0.11 μm) presented no statistically significant difference after 30 days.</abstract>
<abstract>Conclusions:  This study showed that all disinfectant solutions promoted a statistically significant decrease in hardness, whereas with roughness, the materials tested showed a statistically significant increase, except for Tokuyama. Although statistically significant values were registered, these results could not be considered clinically significant.</abstract>
<subject lang="en">
<genre>keywords</genre>
<topic>hard reline acrylic resin</topic>
<topic>denture disinfection</topic>
<topic>surface roughness</topic>
<topic>hardness</topic>
</subject>
<relatedItem type="host">
<titleInfo>
<title>Gerodontology</title>
</titleInfo>
<genre type="journal" authority="ISTEX" authorityURI="https://publication-type.data.istex.fr" valueURI="https://publication-type.data.istex.fr/ark:/67375/JMC-0GLKJH51-B">journal</genre>
<identifier type="ISSN">0734-0664</identifier>
<identifier type="eISSN">1741-2358</identifier>
<identifier type="DOI">10.1111/(ISSN)1741-2358</identifier>
<identifier type="PublisherID">GER</identifier>
<part>
<date>2010</date>
<detail type="volume">
<caption>vol.</caption>
<number>27</number>
</detail>
<detail type="issue">
<caption>no.</caption>
<number>2</number>
</detail>
<extent unit="pages">
<start>147</start>
<end>153</end>
<total>7</total>
</extent>
</part>
</relatedItem>
<identifier type="istex">0372F43A7A10575A0F398B1A6C872F2BD9D90F49</identifier>
<identifier type="ark">ark:/67375/WNG-SB8N56P2-J</identifier>
<identifier type="DOI">10.1111/j.1741-2358.2009.00282.x</identifier>
<identifier type="ArticleID">GER282</identifier>
<accessCondition type="use and reproduction" contentType="copyright">© 2009 The Authors. Journal compilation © 2009 The Gerodontology Association and Blackwell Munksgaard Ltd</accessCondition>
<recordInfo>
<recordContentSource authority="ISTEX" authorityURI="https://loaded-corpus.data.istex.fr" valueURI="https://loaded-corpus.data.istex.fr/ark:/67375/XBH-L0C46X92-X">wiley</recordContentSource>
<recordOrigin>Blackwell Publishing Ltd</recordOrigin>
</recordInfo>
</mods>
<json:item>
<extension>json</extension>
<original>false</original>
<mimetype>application/json</mimetype>
<uri>https://api.istex.fr/document/0372F43A7A10575A0F398B1A6C872F2BD9D90F49/metadata/json</uri>
</json:item>
</metadata>
<serie></serie>
</istex>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Istex/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000171 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Istex/Corpus/biblio.hfd -nk 000171 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    Istex
   |étape=   Corpus
   |type=    RBID
   |clé=     ISTEX:0372F43A7A10575A0F398B1A6C872F2BD9D90F49
   |texte=   Effect of repeated cycles of chemical disinfection on the roughness and hardness of hard reline acrylic resins
}}

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022