Oxidized titanium implants (Nobel Biocare® TiUnite™) compared with turned titanium implants (Nobel Biocare® mark III™) with respect to implant failure in a group of consecutive patients treated with early functional loading and two‐stage protocol
Identifieur interne : 002F16 ( Istex/Checkpoint ); précédent : 002F15; suivant : 002F17Oxidized titanium implants (Nobel Biocare® TiUnite™) compared with turned titanium implants (Nobel Biocare® mark III™) with respect to implant failure in a group of consecutive patients treated with early functional loading and two‐stage protocol
Auteurs : M Ns Jungner [Suède] ; Peter Lundqvist [Suède] ; Stefan Lundgren [Suède]Source :
- Clinical Oral Implants Research [ 0905-7161 ] ; 2005-06.
Descripteurs français
English descriptors
- KwdEn :
- Abutment, Biocares, Bone response, Clinical implant dentistry, Consecutive patients, Ericsson, Experimental study, Gotfredsen, Healing time, Iiit, Implant, Implant failure, Implantes, Implants research, International journal, Jungner, Karlsson, Late failures, Mandible, Maxilla, Maxillofacial, Nobel, Nobel biocare, Nobel biocares mark iiit, Nobel biocares tiunitet, Oral impl, Oral maxillofacial implants, Oxidized, Oxidized surface, Oxidized titanium implants, Primary stability, Protocol, Range weeks, Success rate, Surface roughness, Surgical protocol, Survival rate, Titanium, Titanium implants, Tiunitet, Traditional protocol.
- Teeft :
- Abutment, Biocares, Bone response, Clinical implant dentistry, Consecutive patients, Ericsson, Experimental study, Gotfredsen, Healing time, Iiit, Implant, Implant failure, Implantes, Implants research, International journal, Jungner, Karlsson, Late failures, Mandible, Maxilla, Maxillofacial, Nobel, Nobel biocare, Nobel biocares mark iiit, Nobel biocares tiunitet, Oral impl, Oral maxillofacial implants, Oxidized, Oxidized surface, Oxidized titanium implants, Primary stability, Protocol, Range weeks, Success rate, Surface roughness, Surgical protocol, Survival rate, Titanium, Titanium implants, Tiunitet, Traditional protocol.
Abstract
Objectives: The purpose of this study was to compare two implant types of similar shape but with different surfaces with respect to implant failure.
Url:
DOI: 10.1111/j.1600-0501.2005.01101.x
Affiliations:
Links toward previous steps (curation, corpus...)
Links to Exploration step
ISTEX:276F7B9924D08386BCF49F1FC43E0F3FE3BF5592Le document en format XML
<record><TEI wicri:istexFullTextTei="biblStruct"><teiHeader><fileDesc><titleStmt><title xml:lang="en">Oxidized titanium implants (Nobel Biocare® TiUnite™) compared with turned titanium implants (Nobel Biocare® mark III™) with respect to implant failure in a group of consecutive patients treated with early functional loading and two‐stage protocol</title>
<author><name sortKey="Jungner, M Ns" sort="Jungner, M Ns" uniqKey="Jungner M" first="M Ns" last="Jungner">M Ns Jungner</name>
</author>
<author><name sortKey="Lundqvist, Peter" sort="Lundqvist, Peter" uniqKey="Lundqvist P" first="Peter" last="Lundqvist">Peter Lundqvist</name>
</author>
<author><name sortKey="Lundgren, Stefan" sort="Lundgren, Stefan" uniqKey="Lundgren S" first="Stefan" last="Lundgren">Stefan Lundgren</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:276F7B9924D08386BCF49F1FC43E0F3FE3BF5592</idno>
<date when="2005" year="2005">2005</date>
<idno type="doi">10.1111/j.1600-0501.2005.01101.x</idno>
<idno type="url">https://api.istex.fr/document/276F7B9924D08386BCF49F1FC43E0F3FE3BF5592/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">001332</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Corpus" wicri:corpus="ISTEX">001332</idno>
<idno type="wicri:Area/Istex/Curation">001332</idno>
<idno type="wicri:Area/Istex/Checkpoint">002F16</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Checkpoint">002F16</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title level="a" type="main">Oxidized titanium implants (Nobel Biocare<hi rend="superscript">®</hi>
TiUnite<hi rend="superscript">™</hi>
) compared with turned titanium implants (Nobel Biocare<hi rend="superscript">®</hi>
mark III<hi rend="superscript">™</hi>
) with respect to implant failure in a group of consecutive patients treated with early functional loading and two‐stage protocol</title>
<author><name sortKey="Jungner, M Ns" sort="Jungner, M Ns" uniqKey="Jungner M" first="M Ns" last="Jungner">M Ns Jungner</name>
<affiliation wicri:level="1"><country xml:lang="fr">Suède</country>
<wicri:regionArea>Department of Oral and Maxillofacial Surgery, Umeå University</wicri:regionArea>
<wicri:noRegion>Umeå University</wicri:noRegion>
</affiliation>
</author>
<author><name sortKey="Lundqvist, Peter" sort="Lundqvist, Peter" uniqKey="Lundqvist P" first="Peter" last="Lundqvist">Peter Lundqvist</name>
<affiliation wicri:level="1"><country xml:lang="fr">Suède</country>
<wicri:regionArea>Umeå Implant Center, Umeå</wicri:regionArea>
<wicri:noRegion>Umeå</wicri:noRegion>
</affiliation>
</author>
<author><name sortKey="Lundgren, Stefan" sort="Lundgren, Stefan" uniqKey="Lundgren S" first="Stefan" last="Lundgren">Stefan Lundgren</name>
<affiliation wicri:level="1"><country xml:lang="fr">Suède</country>
<wicri:regionArea>Department of Oral and Maxillofacial Surgery, Umeå University</wicri:regionArea>
<wicri:noRegion>Umeå University</wicri:noRegion>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series><title level="j" type="main">Clinical Oral Implants Research</title>
<title level="j" type="alt">CLINICAL ORAL IMPLANTS RESEARCH</title>
<idno type="ISSN">0905-7161</idno>
<idno type="eISSN">1600-0501</idno>
<imprint><biblScope unit="vol">16</biblScope>
<biblScope unit="issue">3</biblScope>
<biblScope unit="page" from="308">308</biblScope>
<biblScope unit="page" to="312">312</biblScope>
<biblScope unit="page-count">5</biblScope>
<publisher>Munksgaard International Publishers</publisher>
<pubPlace>Oxford, UK</pubPlace>
<date type="published" when="2005-06">2005-06</date>
</imprint>
<idno type="ISSN">0905-7161</idno>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt><idno type="ISSN">0905-7161</idno>
</seriesStmt>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Abutment</term>
<term>Biocares</term>
<term>Bone response</term>
<term>Clinical implant dentistry</term>
<term>Consecutive patients</term>
<term>Ericsson</term>
<term>Experimental study</term>
<term>Gotfredsen</term>
<term>Healing time</term>
<term>Iiit</term>
<term>Implant</term>
<term>Implant failure</term>
<term>Implantes</term>
<term>Implants research</term>
<term>International journal</term>
<term>Jungner</term>
<term>Karlsson</term>
<term>Late failures</term>
<term>Mandible</term>
<term>Maxilla</term>
<term>Maxillofacial</term>
<term>Nobel</term>
<term>Nobel biocare</term>
<term>Nobel biocares mark iiit</term>
<term>Nobel biocares tiunitet</term>
<term>Oral impl</term>
<term>Oral maxillofacial implants</term>
<term>Oxidized</term>
<term>Oxidized surface</term>
<term>Oxidized titanium implants</term>
<term>Primary stability</term>
<term>Protocol</term>
<term>Range weeks</term>
<term>Success rate</term>
<term>Surface roughness</term>
<term>Surgical protocol</term>
<term>Survival rate</term>
<term>Titanium</term>
<term>Titanium implants</term>
<term>Tiunitet</term>
<term>Traditional protocol</term>
</keywords>
<keywords scheme="Teeft" xml:lang="en"><term>Abutment</term>
<term>Biocares</term>
<term>Bone response</term>
<term>Clinical implant dentistry</term>
<term>Consecutive patients</term>
<term>Ericsson</term>
<term>Experimental study</term>
<term>Gotfredsen</term>
<term>Healing time</term>
<term>Iiit</term>
<term>Implant</term>
<term>Implant failure</term>
<term>Implantes</term>
<term>Implants research</term>
<term>International journal</term>
<term>Jungner</term>
<term>Karlsson</term>
<term>Late failures</term>
<term>Mandible</term>
<term>Maxilla</term>
<term>Maxillofacial</term>
<term>Nobel</term>
<term>Nobel biocare</term>
<term>Nobel biocares mark iiit</term>
<term>Nobel biocares tiunitet</term>
<term>Oral impl</term>
<term>Oral maxillofacial implants</term>
<term>Oxidized</term>
<term>Oxidized surface</term>
<term>Oxidized titanium implants</term>
<term>Primary stability</term>
<term>Protocol</term>
<term>Range weeks</term>
<term>Success rate</term>
<term>Surface roughness</term>
<term>Surgical protocol</term>
<term>Survival rate</term>
<term>Titanium</term>
<term>Titanium implants</term>
<term>Tiunitet</term>
<term>Traditional protocol</term>
</keywords>
<keywords scheme="Wicri" type="topic" xml:lang="fr"><term>Protocole</term>
<term>Titane</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract">Objectives: The purpose of this study was to compare two implant types of similar shape but with different surfaces with respect to implant failure.</div>
</front>
</TEI>
<affiliations><list><country><li>Suède</li>
</country>
</list>
<tree><country name="Suède"><noRegion><name sortKey="Jungner, M Ns" sort="Jungner, M Ns" uniqKey="Jungner M" first="M Ns" last="Jungner">M Ns Jungner</name>
</noRegion>
<name sortKey="Lundgren, Stefan" sort="Lundgren, Stefan" uniqKey="Lundgren S" first="Stefan" last="Lundgren">Stefan Lundgren</name>
<name sortKey="Lundqvist, Peter" sort="Lundqvist, Peter" uniqKey="Lundqvist P" first="Peter" last="Lundqvist">Peter Lundqvist</name>
</country>
</tree>
</affiliations>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/Istex/Checkpoint
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 002F16 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Istex/Checkpoint/biblio.hfd -nk 002F16 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Santé |area= EdenteV2 |flux= Istex |étape= Checkpoint |type= RBID |clé= ISTEX:276F7B9924D08386BCF49F1FC43E0F3FE3BF5592 |texte= Oxidized titanium implants (Nobel Biocare® TiUnite™) compared with turned titanium implants (Nobel Biocare® mark III™) with respect to implant failure in a group of consecutive patients treated with early functional loading and two‐stage protocol }}
![]() | This area was generated with Dilib version V0.6.32. | ![]() |