Effects of in vitro cyclic dislodging on retentive force and removal torque of three overdenture attachment systems.

Identifieur interne : 000600 ( PubMed/Checkpoint ); précédent : 000599; suivant : 000601

Effects of in vitro cyclic dislodging on retentive force and removal torque of three overdenture attachment systems.

Auteurs : Mariko Kobayashi [Japon] ; Murali Srinivasan ; Patrick Ammann ; Jean Perriard ; Chikahiro Ohkubo ; Frauke Müller ; Urs C. Belser ; Martin Schimmel

Source :

RBID : pubmed:23566266

Descripteurs français

English descriptors

Abstract

Mandibular two-implant-retained overdentures were suggested as first choice of treatment for edentulous mandibles. However, wear of the attachments may reduce their retention and compromise long-term clinical success.

DOI: 10.1111/clr.12156
PubMed: 23566266


Affiliations:


Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:23566266

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Effects of in vitro cyclic dislodging on retentive force and removal torque of three overdenture attachment systems.</title>
<author>
<name sortKey="Kobayashi, Mariko" sort="Kobayashi, Mariko" uniqKey="Kobayashi M" first="Mariko" last="Kobayashi">Mariko Kobayashi</name>
<affiliation wicri:level="4">
<nlm:affiliation>Division of Fixed Prosthodontics and Occlusion, School of Dental Medicine, University of Geneva, Geneva, Switzerland; Department of Removable Prosthodontics, School of Dental Medicine, Tsurumi University, Yokohama, Japan.</nlm:affiliation>
<country xml:lang="fr">Japon</country>
<wicri:regionArea>Division of Fixed Prosthodontics and Occlusion, School of Dental Medicine, University of Geneva, Geneva, Switzerland; Department of Removable Prosthodontics, School of Dental Medicine, Tsurumi University, Yokohama</wicri:regionArea>
<orgName type="university">Université de Genève</orgName>
<placeName>
<settlement type="city">Genève</settlement>
<region nuts="3" type="region">Canton de Genève</region>
</placeName>
</affiliation>
</author>
<author>
<name sortKey="Srinivasan, Murali" sort="Srinivasan, Murali" uniqKey="Srinivasan M" first="Murali" last="Srinivasan">Murali Srinivasan</name>
</author>
<author>
<name sortKey="Ammann, Patrick" sort="Ammann, Patrick" uniqKey="Ammann P" first="Patrick" last="Ammann">Patrick Ammann</name>
</author>
<author>
<name sortKey="Perriard, Jean" sort="Perriard, Jean" uniqKey="Perriard J" first="Jean" last="Perriard">Jean Perriard</name>
</author>
<author>
<name sortKey="Ohkubo, Chikahiro" sort="Ohkubo, Chikahiro" uniqKey="Ohkubo C" first="Chikahiro" last="Ohkubo">Chikahiro Ohkubo</name>
</author>
<author>
<name sortKey="Muller, Frauke" sort="Muller, Frauke" uniqKey="Muller F" first="Frauke" last="Müller">Frauke Müller</name>
</author>
<author>
<name sortKey="Belser, Urs C" sort="Belser, Urs C" uniqKey="Belser U" first="Urs C" last="Belser">Urs C. Belser</name>
</author>
<author>
<name sortKey="Schimmel, Martin" sort="Schimmel, Martin" uniqKey="Schimmel M" first="Martin" last="Schimmel">Martin Schimmel</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2014">2014</date>
<idno type="RBID">pubmed:23566266</idno>
<idno type="pmid">23566266</idno>
<idno type="doi">10.1111/clr.12156</idno>
<idno type="wicri:Area/PubMed/Corpus">000354</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">000354</idno>
<idno type="wicri:Area/PubMed/Curation">000354</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">000354</idno>
<idno type="wicri:Area/PubMed/Checkpoint">000354</idno>
<idno type="wicri:explorRef" wicri:stream="Checkpoint" wicri:step="PubMed">000354</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Effects of in vitro cyclic dislodging on retentive force and removal torque of three overdenture attachment systems.</title>
<author>
<name sortKey="Kobayashi, Mariko" sort="Kobayashi, Mariko" uniqKey="Kobayashi M" first="Mariko" last="Kobayashi">Mariko Kobayashi</name>
<affiliation wicri:level="4">
<nlm:affiliation>Division of Fixed Prosthodontics and Occlusion, School of Dental Medicine, University of Geneva, Geneva, Switzerland; Department of Removable Prosthodontics, School of Dental Medicine, Tsurumi University, Yokohama, Japan.</nlm:affiliation>
<country xml:lang="fr">Japon</country>
<wicri:regionArea>Division of Fixed Prosthodontics and Occlusion, School of Dental Medicine, University of Geneva, Geneva, Switzerland; Department of Removable Prosthodontics, School of Dental Medicine, Tsurumi University, Yokohama</wicri:regionArea>
<orgName type="university">Université de Genève</orgName>
<placeName>
<settlement type="city">Genève</settlement>
<region nuts="3" type="region">Canton de Genève</region>
</placeName>
</affiliation>
</author>
<author>
<name sortKey="Srinivasan, Murali" sort="Srinivasan, Murali" uniqKey="Srinivasan M" first="Murali" last="Srinivasan">Murali Srinivasan</name>
</author>
<author>
<name sortKey="Ammann, Patrick" sort="Ammann, Patrick" uniqKey="Ammann P" first="Patrick" last="Ammann">Patrick Ammann</name>
</author>
<author>
<name sortKey="Perriard, Jean" sort="Perriard, Jean" uniqKey="Perriard J" first="Jean" last="Perriard">Jean Perriard</name>
</author>
<author>
<name sortKey="Ohkubo, Chikahiro" sort="Ohkubo, Chikahiro" uniqKey="Ohkubo C" first="Chikahiro" last="Ohkubo">Chikahiro Ohkubo</name>
</author>
<author>
<name sortKey="Muller, Frauke" sort="Muller, Frauke" uniqKey="Muller F" first="Frauke" last="Müller">Frauke Müller</name>
</author>
<author>
<name sortKey="Belser, Urs C" sort="Belser, Urs C" uniqKey="Belser U" first="Urs C" last="Belser">Urs C. Belser</name>
</author>
<author>
<name sortKey="Schimmel, Martin" sort="Schimmel, Martin" uniqKey="Schimmel M" first="Martin" last="Schimmel">Martin Schimmel</name>
</author>
</analytic>
<series>
<title level="j">Clinical oral implants research</title>
<idno type="eISSN">1600-0501</idno>
<imprint>
<date when="2014" type="published">2014</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Dental Prosthesis, Implant-Supported</term>
<term>Dental Restoration Failure</term>
<term>Dental Stress Analysis</term>
<term>Denture Precision Attachment</term>
<term>Denture Retention</term>
<term>Denture, Overlay</term>
<term>In Vitro Techniques</term>
<term>Mandible</term>
<term>Materials Testing</term>
<term>Torque</term>
</keywords>
<keywords scheme="KwdFr" xml:lang="fr">
<term>Analyse du stress dentaire</term>
<term>Attachement de précision</term>
<term>Mandibule</term>
<term>Moment de torsion</term>
<term>Overdenture</term>
<term>Prothèse dentaire implanto-portée</term>
<term>Rétention d'appareil de prothèse dentaire</term>
<term>Techniques in vitro</term>
<term>Test de matériaux</term>
<term>Échec de restauration dentaire</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Dental Prosthesis, Implant-Supported</term>
<term>Dental Restoration Failure</term>
<term>Dental Stress Analysis</term>
<term>Denture Precision Attachment</term>
<term>Denture Retention</term>
<term>Denture, Overlay</term>
<term>In Vitro Techniques</term>
<term>Mandible</term>
<term>Materials Testing</term>
<term>Torque</term>
</keywords>
<keywords scheme="MESH" xml:lang="fr">
<term>Analyse du stress dentaire</term>
<term>Attachement de précision</term>
<term>Mandibule</term>
<term>Moment de torsion</term>
<term>Overdenture</term>
<term>Prothèse dentaire implanto-portée</term>
<term>Rétention d'appareil de prothèse dentaire</term>
<term>Techniques in vitro</term>
<term>Test de matériaux</term>
<term>Échec de restauration dentaire</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Mandibular two-implant-retained overdentures were suggested as first choice of treatment for edentulous mandibles. However, wear of the attachments may reduce their retention and compromise long-term clinical success.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Status="MEDLINE" Owner="NLM">
<PMID Version="1">23566266</PMID>
<DateCompleted>
<Year>2015</Year>
<Month>06</Month>
<Day>23</Day>
</DateCompleted>
<DateRevised>
<Year>2014</Year>
<Month>03</Month>
<Day>05</Day>
</DateRevised>
<Article PubModel="Print-Electronic">
<Journal>
<ISSN IssnType="Electronic">1600-0501</ISSN>
<JournalIssue CitedMedium="Internet">
<Volume>25</Volume>
<Issue>4</Issue>
<PubDate>
<Year>2014</Year>
<Month>Apr</Month>
</PubDate>
</JournalIssue>
<Title>Clinical oral implants research</Title>
<ISOAbbreviation>Clin Oral Implants Res</ISOAbbreviation>
</Journal>
<ArticleTitle>Effects of in vitro cyclic dislodging on retentive force and removal torque of three overdenture attachment systems.</ArticleTitle>
<Pagination>
<MedlinePgn>426-34</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1111/clr.12156</ELocationID>
<Abstract>
<AbstractText Label="BACKGROUND" NlmCategory="BACKGROUND">Mandibular two-implant-retained overdentures were suggested as first choice of treatment for edentulous mandibles. However, wear of the attachments may reduce their retention and compromise long-term clinical success.</AbstractText>
<AbstractText Label="AIM" NlmCategory="OBJECTIVE">The aim of this in vitro study was to compare the change in the retentive force and removal torque of three attachment systems during simulation of insertion-removal cycles.</AbstractText>
<AbstractText Label="MATERIALS AND METHODS" NlmCategory="METHODS">Thirty custom-manufactured polyvinyl chloride blocks mimicking an implant-retained overdenture using Locator(®) -, spherical Dalbo(®) -PLUS - and SFI(®) -Bar-attachments on Straumann(®) RN Implants were fabricated. The samples were distributed equally into three groups which were subdivided into two sets of five blocks, one set with implants parallel to one another and the other with angulated implants (12°). All attachments were tightened to 35Ncm, while the fixation screws of the SFI(®) -Bar were tightened to 15Ncm. Testing was carried out with an Instron(®) universal testing machine for a total of 14,600 insertion-removal cycles in 0.9% sodium chloride solution. Retentive forces from cycles 10, 100, 1000, 5000, 10,000 and 14,600 were used for the analysis. The removal torque of the attachments was measured before and at the end of the study. Statistical analysis comprised three-way ANOVA and multiple linear regression models.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">Initially, all three attachment systems demonstrated increasing retentive forces. From cycle 5000 on, Locator(®) -attachments showed lower mean retentive forces than the Dalbo(®) -PLUS and SFI(®) -Bar-groups. The Dalbo(®) -PLUS and SFI(®) -Bar-attachments showed a steady yet not significant increase during the whole observation period. Implant-angulation had no significant influence on the retention forces. The final mean removal torques were significantly reduced. No complete failure was observed.</AbstractText>
<AbstractText Label="CONCLUSIONS AND CLINICAL IMPLICATIONS" NlmCategory="CONCLUSIONS">Within the limits of this in vitro study, it can be concluded that the investigated overdenture attachment systems are sufficiently resistant to wear. However, the Dalbo(®) -Plus- and SFI(®) -Bar- exhibit higher retentive capacities than the Locator(®) -attachment over time. The fixation screw of the SFI(®) -Bar may loosen during long-term use, but these observations might be less important if 1-year recall intervals are respected. An angulation of up to 12° between implants does not seem to have a significant effect on attachment wear.</AbstractText>
<CopyrightInformation>© 2013 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.</CopyrightInformation>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Kobayashi</LastName>
<ForeName>Mariko</ForeName>
<Initials>M</Initials>
<AffiliationInfo>
<Affiliation>Division of Fixed Prosthodontics and Occlusion, School of Dental Medicine, University of Geneva, Geneva, Switzerland; Department of Removable Prosthodontics, School of Dental Medicine, Tsurumi University, Yokohama, Japan.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Srinivasan</LastName>
<ForeName>Murali</ForeName>
<Initials>M</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Ammann</LastName>
<ForeName>Patrick</ForeName>
<Initials>P</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Perriard</LastName>
<ForeName>Jean</ForeName>
<Initials>J</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Ohkubo</LastName>
<ForeName>Chikahiro</ForeName>
<Initials>C</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Müller</LastName>
<ForeName>Frauke</ForeName>
<Initials>F</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Belser</LastName>
<ForeName>Urs C</ForeName>
<Initials>UC</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Schimmel</LastName>
<ForeName>Martin</ForeName>
<Initials>M</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
<PublicationType UI="D013485">Research Support, Non-U.S. Gov't</PublicationType>
</PublicationTypeList>
<ArticleDate DateType="Electronic">
<Year>2013</Year>
<Month>04</Month>
<Day>09</Day>
</ArticleDate>
</Article>
<MedlineJournalInfo>
<Country>Denmark</Country>
<MedlineTA>Clin Oral Implants Res</MedlineTA>
<NlmUniqueID>9105713</NlmUniqueID>
<ISSNLinking>0905-7161</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>D</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName UI="D019094" MajorTopicYN="Y">Dental Prosthesis, Implant-Supported</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D019232" MajorTopicYN="N">Dental Restoration Failure</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003799" MajorTopicYN="N">Dental Stress Analysis</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003834" MajorTopicYN="Y">Denture Precision Attachment</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003781" MajorTopicYN="Y">Denture Retention</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003828" MajorTopicYN="Y">Denture, Overlay</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D066298" MajorTopicYN="N">In Vitro Techniques</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008334" MajorTopicYN="N">Mandible</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008422" MajorTopicYN="N">Materials Testing</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D019415" MajorTopicYN="N">Torque</DescriptorName>
</MeshHeading>
</MeshHeadingList>
<KeywordList Owner="NOTNLM">
<Keyword MajorTopicYN="N">Dalbo®-PLUS</Keyword>
<Keyword MajorTopicYN="N">Locator®</Keyword>
<Keyword MajorTopicYN="N">SFI-Bar®</Keyword>
<Keyword MajorTopicYN="N">dislodging cycles</Keyword>
<Keyword MajorTopicYN="N">in vitro</Keyword>
<Keyword MajorTopicYN="N">overdenture attachment</Keyword>
<Keyword MajorTopicYN="N">removal torque</Keyword>
<Keyword MajorTopicYN="N">retentive force</Keyword>
</KeywordList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="accepted">
<Year>2013</Year>
<Month>02</Month>
<Day>06</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>2013</Year>
<Month>4</Month>
<Day>10</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2013</Year>
<Month>4</Month>
<Day>10</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2015</Year>
<Month>6</Month>
<Day>24</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">23566266</ArticleId>
<ArticleId IdType="doi">10.1111/clr.12156</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
<affiliations>
<list>
<country>
<li>Japon</li>
</country>
<region>
<li>Canton de Genève</li>
</region>
<settlement>
<li>Genève</li>
</settlement>
<orgName>
<li>Université de Genève</li>
</orgName>
</list>
<tree>
<noCountry>
<name sortKey="Ammann, Patrick" sort="Ammann, Patrick" uniqKey="Ammann P" first="Patrick" last="Ammann">Patrick Ammann</name>
<name sortKey="Belser, Urs C" sort="Belser, Urs C" uniqKey="Belser U" first="Urs C" last="Belser">Urs C. Belser</name>
<name sortKey="Muller, Frauke" sort="Muller, Frauke" uniqKey="Muller F" first="Frauke" last="Müller">Frauke Müller</name>
<name sortKey="Ohkubo, Chikahiro" sort="Ohkubo, Chikahiro" uniqKey="Ohkubo C" first="Chikahiro" last="Ohkubo">Chikahiro Ohkubo</name>
<name sortKey="Perriard, Jean" sort="Perriard, Jean" uniqKey="Perriard J" first="Jean" last="Perriard">Jean Perriard</name>
<name sortKey="Schimmel, Martin" sort="Schimmel, Martin" uniqKey="Schimmel M" first="Martin" last="Schimmel">Martin Schimmel</name>
<name sortKey="Srinivasan, Murali" sort="Srinivasan, Murali" uniqKey="Srinivasan M" first="Murali" last="Srinivasan">Murali Srinivasan</name>
</noCountry>
<country name="Japon">
<region name="Canton de Genève">
<name sortKey="Kobayashi, Mariko" sort="Kobayashi, Mariko" uniqKey="Kobayashi M" first="Mariko" last="Kobayashi">Mariko Kobayashi</name>
</region>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV1/Data/PubMed/Checkpoint
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000600 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Checkpoint/biblio.hfd -nk 000600 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV1
   |flux=    PubMed
   |étape=   Checkpoint
   |type=    RBID
   |clé=     pubmed:23566266
   |texte=   Effects of in vitro cyclic dislodging on retentive force and removal torque of three overdenture attachment systems.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Checkpoint/RBID.i   -Sk "pubmed:23566266" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Checkpoint/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV1 

Wicri

This area was generated with Dilib version V0.6.33.
Data generation: Mon Dec 4 11:02:15 2017. Site generation: Tue Sep 29 19:14:38 2020