A method to reversibly degrade proprioceptive feedback in research on human motor control.

Identifieur interne : 000A20 ( Ncbi/Merge ); précédent : 000A19; suivant : 000A21

A method to reversibly degrade proprioceptive feedback in research on human motor control.

Auteurs : Otmar Bock [Allemagne] ; Katja Pipereit ; Andreas Mierau

Source :

RBID : pubmed:17092562

English descriptors

Abstract

In research on human motor skills, it is often desirable to manipulate proprioceptive feedback in order to determine its contribution towards subjects' performance. Here we evaluate an easy-to-use, non-invasive method to temporarily reduce proprioceptive responsiveness. Two physiotherapy vibrators contacted the distal end of the subjects' forearm on the flexor and extensor side; they were either turned off, or they vibrated at 80 Hz with an amplitude of 1mm. We found that vibration substantially impaired subjects' ability to use their hand in an angle matching, a force production and a haptic shape perception task. We also found that vibration strongly attenuated the H-reflex of the ipsilateral M. flexor carpi radialis. These results suggest that agonist-antagonist vibration is a useful method to degrade proprioceptive responsiveness for research on higher motor functions.

DOI: 10.1016/j.jneumeth.2006.09.010
PubMed: 17092562

Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:17092562

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">A method to reversibly degrade proprioceptive feedback in research on human motor control.</title>
<author>
<name sortKey="Bock, Otmar" sort="Bock, Otmar" uniqKey="Bock O" first="Otmar" last="Bock">Otmar Bock</name>
<affiliation wicri:level="3">
<nlm:affiliation>Institute of Physiology and Anatomy, German Sport University, 50933 Koln, Germany. bock@dshs-koeln.de</nlm:affiliation>
<country xml:lang="fr">Allemagne</country>
<wicri:regionArea>Institute of Physiology and Anatomy, German Sport University, 50933 Koln</wicri:regionArea>
<placeName>
<region type="land" nuts="1">Rhénanie-du-Nord-Westphalie</region>
<region type="district" nuts="2">District de Cologne</region>
<settlement type="city">Cologne</settlement>
</placeName>
</affiliation>
</author>
<author>
<name sortKey="Pipereit, Katja" sort="Pipereit, Katja" uniqKey="Pipereit K" first="Katja" last="Pipereit">Katja Pipereit</name>
</author>
<author>
<name sortKey="Mierau, Andreas" sort="Mierau, Andreas" uniqKey="Mierau A" first="Andreas" last="Mierau">Andreas Mierau</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2007">2007</date>
<idno type="doi">10.1016/j.jneumeth.2006.09.010</idno>
<idno type="RBID">pubmed:17092562</idno>
<idno type="pmid">17092562</idno>
<idno type="wicri:Area/PubMed/Corpus">001735</idno>
<idno type="wicri:Area/PubMed/Curation">001735</idno>
<idno type="wicri:Area/PubMed/Checkpoint">001498</idno>
<idno type="wicri:Area/Ncbi/Merge">000A20</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">A method to reversibly degrade proprioceptive feedback in research on human motor control.</title>
<author>
<name sortKey="Bock, Otmar" sort="Bock, Otmar" uniqKey="Bock O" first="Otmar" last="Bock">Otmar Bock</name>
<affiliation wicri:level="3">
<nlm:affiliation>Institute of Physiology and Anatomy, German Sport University, 50933 Koln, Germany. bock@dshs-koeln.de</nlm:affiliation>
<country xml:lang="fr">Allemagne</country>
<wicri:regionArea>Institute of Physiology and Anatomy, German Sport University, 50933 Koln</wicri:regionArea>
<placeName>
<region type="land" nuts="1">Rhénanie-du-Nord-Westphalie</region>
<region type="district" nuts="2">District de Cologne</region>
<settlement type="city">Cologne</settlement>
</placeName>
</affiliation>
</author>
<author>
<name sortKey="Pipereit, Katja" sort="Pipereit, Katja" uniqKey="Pipereit K" first="Katja" last="Pipereit">Katja Pipereit</name>
</author>
<author>
<name sortKey="Mierau, Andreas" sort="Mierau, Andreas" uniqKey="Mierau A" first="Andreas" last="Mierau">Andreas Mierau</name>
</author>
</analytic>
<series>
<title level="j">Journal of neuroscience methods</title>
<idno type="ISSN">0165-0270</idno>
<imprint>
<date when="2007" type="published">2007</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Adaptation, Physiological (physiology)</term>
<term>Adult</term>
<term>Afferent Pathways (physiology)</term>
<term>Cues</term>
<term>Denervation (instrumentation)</term>
<term>Denervation (methods)</term>
<term>Feedback (physiology)</term>
<term>Female</term>
<term>H-Reflex (physiology)</term>
<term>Hand (physiology)</term>
<term>Humans</term>
<term>Male</term>
<term>Mechanoreceptors (physiology)</term>
<term>Motor Skills (physiology)</term>
<term>Movement (physiology)</term>
<term>Muscle Contraction (physiology)</term>
<term>Muscle, Skeletal (physiology)</term>
<term>Neurophysiology (instrumentation)</term>
<term>Neurophysiology (methods)</term>
<term>Physical Stimulation (instrumentation)</term>
<term>Physical Stimulation (methods)</term>
<term>Proprioception (physiology)</term>
<term>Touch (physiology)</term>
<term>Vibration (adverse effects)</term>
</keywords>
<keywords scheme="MESH" qualifier="adverse effects" xml:lang="en">
<term>Vibration</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en">
<term>Denervation</term>
<term>Neurophysiology</term>
<term>Physical Stimulation</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en">
<term>Denervation</term>
<term>Neurophysiology</term>
<term>Physical Stimulation</term>
</keywords>
<keywords scheme="MESH" qualifier="physiology" xml:lang="en">
<term>Adaptation, Physiological</term>
<term>Afferent Pathways</term>
<term>Feedback</term>
<term>H-Reflex</term>
<term>Hand</term>
<term>Mechanoreceptors</term>
<term>Motor Skills</term>
<term>Movement</term>
<term>Muscle Contraction</term>
<term>Muscle, Skeletal</term>
<term>Proprioception</term>
<term>Touch</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Adult</term>
<term>Cues</term>
<term>Female</term>
<term>Humans</term>
<term>Male</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">In research on human motor skills, it is often desirable to manipulate proprioceptive feedback in order to determine its contribution towards subjects' performance. Here we evaluate an easy-to-use, non-invasive method to temporarily reduce proprioceptive responsiveness. Two physiotherapy vibrators contacted the distal end of the subjects' forearm on the flexor and extensor side; they were either turned off, or they vibrated at 80 Hz with an amplitude of 1mm. We found that vibration substantially impaired subjects' ability to use their hand in an angle matching, a force production and a haptic shape perception task. We also found that vibration strongly attenuated the H-reflex of the ipsilateral M. flexor carpi radialis. These results suggest that agonist-antagonist vibration is a useful method to degrade proprioceptive responsiveness for research on higher motor functions.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="MEDLINE">
<PMID Version="1">17092562</PMID>
<DateCreated>
<Year>2007</Year>
<Month>02</Month>
<Day>19</Day>
</DateCreated>
<DateCompleted>
<Year>2007</Year>
<Month>05</Month>
<Day>10</Day>
</DateCompleted>
<Article PubModel="Print-Electronic">
<Journal>
<ISSN IssnType="Print">0165-0270</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>160</Volume>
<Issue>2</Issue>
<PubDate>
<Year>2007</Year>
<Month>Mar</Month>
<Day>15</Day>
</PubDate>
</JournalIssue>
<Title>Journal of neuroscience methods</Title>
<ISOAbbreviation>J. Neurosci. Methods</ISOAbbreviation>
</Journal>
<ArticleTitle>A method to reversibly degrade proprioceptive feedback in research on human motor control.</ArticleTitle>
<Pagination>
<MedlinePgn>246-50</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText>In research on human motor skills, it is often desirable to manipulate proprioceptive feedback in order to determine its contribution towards subjects' performance. Here we evaluate an easy-to-use, non-invasive method to temporarily reduce proprioceptive responsiveness. Two physiotherapy vibrators contacted the distal end of the subjects' forearm on the flexor and extensor side; they were either turned off, or they vibrated at 80 Hz with an amplitude of 1mm. We found that vibration substantially impaired subjects' ability to use their hand in an angle matching, a force production and a haptic shape perception task. We also found that vibration strongly attenuated the H-reflex of the ipsilateral M. flexor carpi radialis. These results suggest that agonist-antagonist vibration is a useful method to degrade proprioceptive responsiveness for research on higher motor functions.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Bock</LastName>
<ForeName>Otmar</ForeName>
<Initials>O</Initials>
<AffiliationInfo>
<Affiliation>Institute of Physiology and Anatomy, German Sport University, 50933 Koln, Germany. bock@dshs-koeln.de</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Pipereit</LastName>
<ForeName>Katja</ForeName>
<Initials>K</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Mierau</LastName>
<ForeName>Andreas</ForeName>
<Initials>A</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
<PublicationType UI="D013485">Research Support, Non-U.S. Gov't</PublicationType>
</PublicationTypeList>
<ArticleDate DateType="Electronic">
<Year>2006</Year>
<Month>11</Month>
<Day>07</Day>
</ArticleDate>
</Article>
<MedlineJournalInfo>
<Country>Netherlands</Country>
<MedlineTA>J Neurosci Methods</MedlineTA>
<NlmUniqueID>7905558</NlmUniqueID>
<ISSNLinking>0165-0270</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000222">Adaptation, Physiological</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000502">physiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000328">Adult</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000344">Afferent Pathways</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000502">physiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D003463">Cues</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D003714">Denervation</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000295">instrumentation</QualifierName>
<QualifierName MajorTopicYN="N" UI="Q000379">methods</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D005246">Feedback</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000502">physiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D005260">Female</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006181">H-Reflex</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000502">physiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006225">Hand</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000502">physiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D008297">Male</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D008465">Mechanoreceptors</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000502">physiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D009048">Motor Skills</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000502">physiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D009068">Movement</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000502">physiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D009119">Muscle Contraction</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000502">physiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D018482">Muscle, Skeletal</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000502">physiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D009482">Neurophysiology</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000295">instrumentation</QualifierName>
<QualifierName MajorTopicYN="N" UI="Q000379">methods</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D010812">Physical Stimulation</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000295">instrumentation</QualifierName>
<QualifierName MajorTopicYN="N" UI="Q000379">methods</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D011434">Proprioception</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000502">physiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D014110">Touch</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000502">physiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D014732">Vibration</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000009">adverse effects</QualifierName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="received">
<Year>2006</Year>
<Month>4</Month>
<Day>4</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="revised">
<Year>2006</Year>
<Month>9</Month>
<Day>6</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="accepted">
<Year>2006</Year>
<Month>9</Month>
<Day>14</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="aheadofprint">
<Year>2006</Year>
<Month>11</Month>
<Day>7</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2006</Year>
<Month>11</Month>
<Day>10</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2007</Year>
<Month>5</Month>
<Day>11</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>2006</Year>
<Month>11</Month>
<Day>10</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pii">S0165-0270(06)00462-6</ArticleId>
<ArticleId IdType="doi">10.1016/j.jneumeth.2006.09.010</ArticleId>
<ArticleId IdType="pubmed">17092562</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
<affiliations>
<list>
<country>
<li>Allemagne</li>
</country>
<region>
<li>District de Cologne</li>
<li>Rhénanie-du-Nord-Westphalie</li>
</region>
<settlement>
<li>Cologne</li>
</settlement>
</list>
<tree>
<noCountry>
<name sortKey="Mierau, Andreas" sort="Mierau, Andreas" uniqKey="Mierau A" first="Andreas" last="Mierau">Andreas Mierau</name>
<name sortKey="Pipereit, Katja" sort="Pipereit, Katja" uniqKey="Pipereit K" first="Katja" last="Pipereit">Katja Pipereit</name>
</noCountry>
<country name="Allemagne">
<region name="Rhénanie-du-Nord-Westphalie">
<name sortKey="Bock, Otmar" sort="Bock, Otmar" uniqKey="Bock O" first="Otmar" last="Bock">Otmar Bock</name>
</region>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Ncbi/Merge
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000A20 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Ncbi/Merge/biblio.hfd -nk 000A20 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Ncbi
   |étape=   Merge
   |type=    RBID
   |clé=     pubmed:17092562
   |texte=   A method to reversibly degrade proprioceptive feedback in research on human motor control.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Ncbi/Merge/RBID.i   -Sk "pubmed:17092562" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Ncbi/Merge/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024